Mrc Mina
Print Q88   
IMO/VIN Callsign Flag Service Year
9464285 V7SP7 MARSHALL ISLANDS Tank Ship 2009
Activity# Port Date Activity - Description Deficiencies
5078711 North Charleston, South Carolina Mar 05, 15 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
ElectricalLighting (emergency)
DescriptionDue DateResolved
CODE 0699. ACTION 17C. MUSTER AND EMBARKATION STATIONS SHALL BE ADEQUATELY LUMINATED BY LIGHTING SUPPLIED FROM THE EMERGENCY SOURCE OF ELECTRICAL POWER. DURING THE COURSE OF THE EXAM ALL THE EMBARKATION LIGHTING WERE FOUND NOT WORKING. 74 SOLAS (2014) III/11.4Yes
Resolved DateResolution
Mar 11, 15EMBARKATION LIGHTING WERE FIXED AND WITNESSED AS OPERATIONAL.
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
CODE 1710. ACTION 10C. EACH COMPLETED PAGE OF THE OIL RECORD BOOK PART I SHALL BE SIGNED BY THE MASTER OF SHIP. THE MASTER HAS NOT SIGNED THE COMPLETED PAGES OF THE ORB SINCE 12JAN15. MARPOL I/17.4Mar 10, 15Yes
Resolved DateResolution
Mar 10, 15MASTER WAS INSTRUCTED ON HIS RESPONSIBILITIES AND EACH INCOMPLETE PAGE WAS SIGNED.
4699146 New Orleans, Louisiana Aug 28, 13 Vessel Operational Control - Agency Action Complete
4673213 Houston, Texas Aug 12, 13 Vessel Inspection - Approved Inspection
4007884 New Orleans, Louisiana May 10, 11 Vessel Operational Control - Agency Action Complete
4002498 Houston, Texas May 08, 11 Vessel Operational Control - Agency Action Complete
3927366 TEXAS CITY, Texas Jan 20, 11 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
LifesavingInflatable Liferafts
DescriptionDue DateResolved
Inflatable life rafts hydrostatic release system is not in accordance with the vessel's SOLAS Lifesaving Training Manual. Prior to departure.Yes
Resolved DateResolution
Jan 22, 11SOLAS Life Saving Training Manual has been amended to reflect proper hydrostatic release system installation for the inflatable life raft.
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
Vessel's nitrogen generator system O2 analyzer sensor is not operating properly. Prior to departure.Yes
Resolved DateResolution
Jan 22, 11Received class survey report that vessel is carrying a cargo that is not required to be inerted and vessel has 90 days to receive part to replace bad sensor.
SystemSubsystemCause
Fire FightingStructural - A Class Divisions
DescriptionDue DateResolved
Vessel's self closing Class "A" fire doors located along the vessel's stairway enclosures have hold-back devices attached.Yes
Resolved DateResolution
Jan 21, 11Crew member’s unscrewed and removed metal hold back devices.
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel August 12,2013 August 12,2015 N/A
Certificate of Fitness - Chemical Carrier September 23,2014 August 26,2019 BV
Classification Document September 23,2014 August 26,2019 BV
International Load Line Certificate September 23,2014 August 26,2019 BV
International Oil Pollution Prevention Certificate September 23,2014 August 26,2019 BV
ISM - Document Of Compliance December 16,2009 September 24,2014 BV
ISM - Safety Management Certificate December 28,2009 December 15,2014 BV
Minimum Safe Manning Document September 9,2009 MH
SOLAS Cargo Ship Safety Construction Certificate September 23,2014 August 26,2019 BV
SOLAS Cargo Ship Safety Equipment Certificate September 23,2014 August 26,2019 BV
SOLAS Cargo Ship Safety Radio Certificate September 23,2014 August 26,2019 BV
Tonnage Certificate, International August 18,2009 BV