Activity# Port Date Activity - Description Deficiencies
7096178 Christiansted, Virgin Islands Dec 10, 20 Vessel Inspection - Approved Inspection
6832117 San Pedro, California Oct 14, 19 Vessel Inspection - Approved Inspection
6535291 San Pedro, California Sep 13, 18 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Condition of ship and its equipment shall be maintained to conform w/ provisions of present regulations to ensure the ship in all respects remain fit to proceed to sea w/o danger to ship or persons on board. Expansion bellows on IGS blowers were found cracked and severly worn. 74SOLAS(14) I/11(a)Yes
Resolved DateResolution
Sep 19, 18Received satisfactory class report from ABS attesting to the replacement and operations of the replaced expansion bellows.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Condition of ship and its equipment shall be maintained to conform with provisions of present regulations to ensure the ship in all respects remain fit to proceed to sea without danger to ship or persons on board. PSCO disovered forward packing gland on stripping pump was leaking cargo. 74SOLAS(14) I/11(a)Yes
Resolved DateResolution
Sep 19, 18Received satisfactory class report from ABS attesting to renewing the packing gland on the stripping pump and properly functioning.
6405025 New Orleans, Louisiana May 03, 18 Vessel Inspection - Approved Inspection
6401502 New Orleans, Louisiana Apr 29, 18 Vessel Operational Control - Agency Action Complete
6212128 San Pedro, California Jul 20, 17 Vessel Inspection - Approved Inspection
6046351 San Pedro, California Nov 23, 16 Vessel Operational Control - Agency Action Complete
5976396 San Francisco, California Aug 18, 16 Vessel Inspection - Approved Inspection
5790112 San Pedro, California Jan 03, 16 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
ON EACH TANKER 10,000 GT OR MORE, THE DUAL RADAR SYSTEM BY THIS PART MUST HAVE A SHORT AND LONG RANGE CAPABILITY. "S" BAND RADAR WAS REPORTED INOPERABLE, IAW 33CFR164.37. IN ACCORDANCE..... SEE NARRATIVE FOR FULL DEF.Yes
Resolved DateResolution
Jan 07, 16RECEIVED REPORT FROM VESSEL'S CLASS, ABS, THAT THEY ATTENDED THE VESSEL ON 06JAN2016 IN REGARDS TO THE DOWN S-BAND RADAR. A NEW MODULATION TRANSFORMER, FURUNO, MODEL NO. RT9273, WAS INSTALLED. THE S-BAND RADAR FULLY OPERATIONAL AND CONSIDERED SATISFACTORY
5179600 San Francisco, California Jul 13, 15 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
LifesavingRescue BoatImproper Installation
DescriptionDue DateResolved
0610: Each survival craft shall be stowed in a state of continuous readiness. Starboard side rescue boat main drive shaft appears to be warped and binding when tested by hand. Excessive vibration during testing. 74 SOLAS (14) CONS III/13.1.3 Control Action: 17acJul 15, 15Yes
Resolved DateResolution
Jul 14, 15Corrected to the satisfaction of the attending Classification Surveyor.
SystemSubsystemCause
Fire FightingStructural - A Class DivisionsImproper/Lack of Maintenance
DescriptionDue DateResolved
0799; The fire integrity of divisions shall be maintained at openings and penetrations. Multiple doors throughout the superstructure, including the stairwells and gallery are not properly self-closing as required, compromising the integrity of the boundaries. Additionally the drying room is been used as a storage locker, 74 SOLAAS (04 Con) II-2/9.1.3, 10C.Jul 13, 15Yes
Resolved DateResolution
Jul 13, 15Spoke with the Captain, Chief Officer and Chief Engineer about adjusting the doors and maintenance of same.
SystemSubsystemCause
EngineeringGenerator (propulsion/auxiliary-electric)Improper/Lack of Maintenance
DescriptionDue DateResolved
1430: Manual starting of the emergency generator must be demonstrated as being effective during testing of the emergency generator, the generator shut off after two minutes of running not under load. 74 SOLAS (04) II-1/44 Control Action: 17acJul 15, 15Yes
Resolved DateResolution
Jul 14, 15Corrected to the satisfaction of the attending Classification Surveyor.
SystemSubsystemCause
DocumentationLogs/RecordsImproper/Lack of Maintenance
DescriptionDue DateResolved
2510; Vessel must maintain a Ballast Water Management Plan and Bio-Fouling Plat that he crew shall follow. Vessel is using incorrect forms for training and sediment documentation and crew in not recording Bio-Fouling procedures, 33CFR155.2050(g), 10C.Jul 13, 15Yes
Resolved DateResolution
Jul 13, 15Discussed items with the Captain, Chief Officer and Chief Engineer.
SystemSubsystemCause
DocumentationManuals/Policy DocumentationImproper/Lack of Maintenance
DescriptionDue DateResolved
2535; Transfer procedures must include the items listed in 33CFR155.750. Vessel's transfer procedures are missing communication, product description and identification of all involved personnel, 33CFR155.750, 10C.Jul 13, 15Yes
Resolved DateResolution
Jul 13, 15Reviewed the procedures with the Captain and Chief Officer.
4918521 San Francisco, California Jul 11, 14 Vessel Inspection - Approved Inspection
4810751 San Pedro, California Mar 05, 14 Vessel Operational Control - Approved Inspection
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
INOP X-Band radar LOD issued 05MAR2014Mar 11, 14Yes
Resolved DateResolution
Mar 11, 1411MAR14: Received tech report stating the vessel replaced a worn magnetron and is fully operational.
4623383 San Francisco, California Jun 26, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
2535; Vessel does not have a Biofouling Management Plan as per IMO Resolution, MEPC 207(62), 33 CFR 151.2050 (g)(3).Jun 26, 13Yes
Resolved DateResolution
Jun 26, 13Discussed with Captain, Chief Officer and Chief Engineer.
4534368 San Francisco, California Feb 16, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
NavigationCollision/Grounding AvoidanceImproper/Lack of Maintenance
DescriptionDue DateResolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Sec S.F. was notified via the Bar Pilot that the X-band radar is inoperable. Vessel must make repairs prior to departure from Sec S.F. COTP zone. 17cYes
Resolved DateResolution
Feb 18, 13Vessel agent forwarded a copy of the technician report to Sec San Fran attesting to the repairs to the X-Band Radar. Technician tested both the X-Band and the S-Band radars and found them to be fully operational.
4502829 San Diego, California Dec 15, 12 Vessel Inspection - Approved Inspection
4481815 San Francisco, California Nov 09, 12 Boarding - Agency Action Complete
4304481 San Pedro, California May 15, 12 Vessel Inspection - Agency Action Complete
4036420 San Pedro, California Jun 08, 11 Vessel Inspection - Agency Action Complete
4000910 San Francisco, California May 03, 11 Boarding - Agency Action Complete
3928637 San Pedro, California Jan 19, 11 Vessel Inspection - Approved Inspection
3748591 San Francisco, California May 27, 10 Vessel Inspection - Approved Inspection
3678265 San Francisco, California Feb 10, 10 Boarding - Agency Action Complete
3539043 San Pedro, California Jul 19, 09 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringDiesel Engine (propulsion-direct drive)
DescriptionDue DateResolved
Vessel reported a loss of bridge main engine maneuvering control while transiting inbound to the Port of LA/LB. Vessel is to provide a technician's report and satisfactory class report attesting to the proper operation of the bridge main engine control system and final determination on the cause of the failure prior to departing the Port of LA/LB.Yes
Resolved DateResolution
Jul 22, 09Class report received attesting to the correct operational control of the MDE.
3538539 San Pedro, California Jul 18, 09 Boarding - Agency Action Complete
3533877 San Pedro, California Jul 13, 09 Vessel Operational Control - Agency Action Complete
3512929 San Francisco, California Jun 24, 09 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
DocumentationManuals/Policy Documentation
DescriptionDue DateResolved
2045 - Cargo transfer procedures not in accordance with US regulations. 10Jun 24, 09Yes
Resolved DateResolution
Jun 24, 09Electronic template provided to master.
SystemSubsystemCause
Operations/ManagementBallast Water Managment
DescriptionDue DateResolved
2510- Ballast Items - No record of crew training and familiarization. No Sampling Point list or diagram provided in plan. 70abcJun 26, 09Yes
Resolved DateResolution
Jul 22, 09Class report received attesting to the records for crew training and familiarization for ballast operations being onboard. Diagram listing the sampling points on the vessel are now onboard.
SystemSubsystemCause
DocumentationManuals/Policy Documentation
DescriptionDue DateResolved
2535 - SOLAS Training Manual not ship specific. Generic information provided. 70abcJun 26, 09Yes
Resolved DateResolution
Jul 22, 09Class report was received in which the surveyor attests to the SOLAS training manual being onboard.
Documents Issued Expires Agency
Classification Document September 19,2019 May 27,2024 ABS
COC-TVE Annual October 15,2019 October 15,2021 N/A
COC-TVE Renewal October 15,2019 October 15,2021 N/A
International Load Line Certificate September 19,2019 May 27,2024 ABS
International Oil Pollution Prevention Certificate September 9,2014 May 27,2019 ABS
ISM - Document Of Compliance June 29,2017 July 15,2022 N/A
ISM - Safety Management Certificate October 14,2019 November 16,2024 LR
Minimum Safe Manning Document March 29,2018 LR
SOLAS Cargo Ship Safety Construction Certificate September 19,2019 May 27,2024 ABS
SOLAS Cargo Ship Safety Equipment Certificate September 19,2019 May 27,2024 ABS
SOLAS Cargo Ship Safety Radio Certificate September 19,2019 May 27,2024 ABS
Tonnage Certificate, International June 1,2016 ABS