Advantage Point
Print Q88   
IMO/VIN Callsign Flag Service Year
9327384 C4KC2 MARSHALL ISLANDS Tank Ship
Activity# Port Date Activity - Description Deficiencies
7162543 NEW HAVEN, Connecticut Mar 25, 21 Vessel Inspection - Agency Action Complete
7162102 Belfast, Maine Mar 24, 21 Vessel Operational Control - Agency Action Complete
7159055 Belfast, Maine Mar 19, 21 Vessel Inspection - Approved Inspection
7142303 CORPUS CHRISTI, Texas Feb 17, 21 Vessel Operational Control - Agency Action Complete
7140304 PHILADELPHIA, Pennsylvania Feb 13, 21 Vessel Operational Control - Approved Inspection
7137304 PHILADELPHIA, Pennsylvania Feb 09, 21 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
Where the atmosphere in double hull spaces cannot be reliably measured using flexible gas sampling hoses, such spaces shall be fitted with permanent gas sampling lines. PSCO observed the fixed gas detection system is not operating as intended. During testing of LEL alarm the system kept receiving flow fault alarms. 74SOLAS(14) II-2/4.5.7.2.2Yes
Resolved DateResolution
Feb 10, 21USCG satisfied with class survey reports
4455637 STATEN ISLAND, New York Oct 02, 12 Vessel Inspection - Approved Inspection
4118661 TEXAS CITY, Texas Aug 23, 11 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
LifesavingLifeboat
DescriptionDue DateResolved
0610 Life boats are not ready for immediate use. Stern launch lifeboat's batteries will not start the engine due to both batterie's explosion proof seals being wasted. Solas 2004 Cons. Reg 20.2 and LSA Ch. IV 4.4.6.2Yes
Resolved DateResolution
Aug 24, 11Recieved Class Report attesting to the repair of the life boat
SystemSubsystemCause
EngineeringGenerator (propulsion/auxiliary-electric)
DescriptionDue DateResolved
0610-All electrical auxillary instalations shall be in operational conditional condition. The emergency gaenerator will start but will not shut down. Crew had to shut the fuel valve to shut down the emergency generator. Solas 2004 Cons. CH II-1 Reg 40.1 10CAug 23, 11Yes
Resolved DateResolution
Aug 23, 11Crew fixed prior to the PSCE left the vessel.
3816675 San Juan, Puerto Rico Aug 06, 10 Vessel Inspection - Approved Inspection
3711783 San Juan, Puerto Rico Apr 11, 10 Boarding - Agency Action Complete
3556896 Wilmington, North Carolina Aug 11, 09 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
ElectricalElectric Generation Source (emergency)Unknown
DescriptionDue DateResolved
Emergency generator automatic start is inoperable due to unknown reasons. Emergency generator must start automatically upon failure of the main source of electrical power.Yes
Resolved DateResolution
Aug 12, 09Vessel replaced batteries for the emergency generator. All tests satisfactory.
2827666 New Orleans, Louisiana Nov 24, 06 Vessel Inspection - Approved Inspection
2826511 New Orleans, Louisiana Nov 21, 06 Vessel Inspection - Approved Inspection
2820497 TEXAS CITY, Texas Nov 14, 06 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
Deck/CargoCargo Stowage
DescriptionDue DateResolved
All cargo tanks exceeded 98.5% volume capacity. This volume of cargo exceeded the 98% setting on the overfill alarms and is exceeds US maximum cargo tank capcity regulations per 33 CFR 155.775. Conduct training on cargo loading procedures.Yes
Resolved DateResolution
Nov 24, 06Received class report from DNV satisfying requirement.
SystemSubsystemCause
Deck/CargoInert Gas SystemUnknown
DescriptionDue DateResolved
IGG motor for remote operation of the IGG from the Cargo Control Room is inoperative. Repair or replace motor. Until the item is repaired a live watch must be placed at the local IGG operating console w/ comms with the Person in Charge of cargo operations whenever the IGG is operated.Dec 14, 06Yes
Resolved DateResolution
Aug 11, 09Class Reports reviewed and verified.
SystemSubsystemCause
Deck/CargoInert Gas SystemDamaged By Earlier Event
DescriptionDue DateResolved
PV Breaker has a deep fracture in the upper left corner of the viewing glass. Replace viewing glass.Dec 14, 06Yes
Resolved DateResolution
Aug 11, 09Class Reports reviewed and verified.
2820839 Houston, Texas Nov 14, 06 Boarding - Agency Action Complete
Documents Issued Expires Agency
Certificate of Fitness - Chemical Carrier September 17,2020 N/A
Classification Document July 28,2011 June 8,2016 DNV
COC-TVE Annual August 6,2010 August 11,2011 N/A
COC-TVE Renewal August 11,2009 August 11,2011 N/A
International Certificate of Fitness - Chemical June 20,2011 June 8,2016 DNV
International Load Line Certificate July 3,2018 June 8,2021 DNV GL
International Oil Pollution Prevention Certificate July 28,2011 June 8,2016 DNV
ISM - Document Of Compliance July 19,2019 July 5,2023 DNV GL
ISM - Safety Management Certificate October 12,2009 September 17,2014 ABS
Minimum Safe Manning Document June 1,2006 CY
SOLAS Cargo Ship Safety Construction Certificate December 23,2019 June 8,2021 DNV GL
SOLAS Cargo Ship Safety Equipment Certificate April 10,2019 June 8,2021 DNV GL
SOLAS Cargo Ship Safety Radio Certificate July 28,2011 June 8,2016 DNV
Tonnage Certificate, International April 26,2006 DNV