Nord Inspiration
Print Q88   
IMO/VIN Callsign Flag Service Year
9441855 3FDJ3 PANAMA Tank Ship 2010
Activity# Port Date Activity - Description Deficiencies
6743809 San Pedro, California Jul 09, 19 Vessel Inspection - Approved Inspection
6567346 DUTCH HARBOR, Alaska Oct 29, 18 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemDamaged By Earlier Event
DescriptionDue DateResolved
Doors fitted in boundary bulkheads of machinery spaces of category A chall be reasonably gastight and self-closing. PSCOs foung the door leading into the machinery room to be warped, missing a lock, and would not self close. Cite SOLAS 2014 Ch. II-2 Reg 9.4.2.1 Action 40COct 31, 18Yes
Resolved DateResolution
Jul 10, 19Class cleared the DEF.
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. A few inches of water was discovered in the emergency fire pump space. PSCOs ran the pump and the water did not appear to accumulate but was unable to drain due to spring loaded plug failure. Cite: SOLAS 2014 CH1 Reg 11 (a) Action: 40aOct 31, 18Yes
Resolved DateResolution
Jul 10, 19Class cleared the DEF.
6260368 DUTCH HARBOR, Alaska Sep 08, 17 Vessel Inspection - Approved Inspection
5975570 New Orleans, Louisiana Sep 02, 16 Vessel Inspection - Approved Inspection
5726444 STATEN ISLAND, New York Sep 19, 15 Vessel Inspection - Approved Inspection
4687744 STATEN ISLAND, New York Aug 17, 13 Vessel Operational Control - Agency Action Complete
4687545 STATEN ISLAND, New York Aug 17, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringGenerator (propulsion/auxiliary-electric)
DescriptionDue DateResolved
2050 - Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration with a stored energy capability of at least three consecutive starts. Both sets of accumulating battery packs depleted and unable to start emergency generator. Ensure charging devices are in proper operation. 74 SOLAS 09 II-1/44.2Yes
Resolved DateResolution
Aug 18, 13Received, reviewed & accepted class report from Nippon Kaiji Kyokai stating the deficiency was rectififed. Technician found a blown fuse for the rectifier unit. Fuse replaced & charing unit was found in full working order & able to charge battery banks
4416551 Savannah, Georgia Aug 25, 12 Vessel Inspection - Approved Inspection
4229314 PHILADELPHIA, Pennsylvania Jan 22, 12 Boarding - Agency Action Complete
4090211 STATEN ISLAND, New York Jul 22, 11 Vessel Inspection - Approved Inspection
3928397 CORPUS CHRISTI, Texas Jan 19, 11 Vessel Inspection - Approved Inspection
3832592 New Orleans, Louisiana Aug 28, 10 Vessel Inspection - Approved Inspection
3779387 Miami Beach, Florida Jun 28, 10 Vessel Inspection - Agency Action Complete
Documents Issued Expires Agency
Classification Document June 18,2015 May 17,2020 NKK
COC-TVE Annual September 7,2017 September 7,2019 N/A
COC-TVE Renewal September 7,2017 September 7,2019 N/A
International Load Line Certificate June 18,2015 May 17,2020 NKK
International Oil Pollution Prevention Certificate May 18,2010 October 17,2010 NKK
ISM - Document Of Compliance May 26,2017 May 22,2022 N/A
ISM - Safety Management Certificate September 30,2015 October 16,2020 N/A
Minimum Safe Manning Document November 14,2013 PA
SOLAS Cargo Ship Safety Construction Certificate June 18,2015 May 17,2020 NKK
SOLAS Cargo Ship Safety Equipment Certificate July 4,2012 September 3,2012 NKK
SOLAS Cargo Ship Safety Radio Certificate June 18,2015 May 17,2020 NKK
Tonnage Certificate, International May 18,2010 NKK