IMO/VIN
Callsign
Flag
Service
Year
9479838
3FWB6
PANAMA
Tank Ship
2011
Activity#
Port
Date
Activity - Description
Deficiencies
7121179
STATEN ISLAND, New York
Jan 07, 21
Vessel Operational Control - Agency Action Complete
7007631
WASHINGTON, District of Columbia
Jul 15, 20
Incident Investigation - Agency Action Complete
7005840
SOUTH PORTLAND, Maine
Jul 14, 20
Vessel Inspection - Approved Inspection
6998808
NEW HAVEN, Connecticut
Jul 06, 20
Vessel Inspection - Approved Inspection
6998032
STATEN ISLAND, New York
Jul 06, 20
Vessel Operational Control - Agency Action Complete
6750429
STATEN ISLAND, New York
Jul 15, 19
Vessel Inspection - Approved Inspection
6606115
Houston, Texas
Jan 06, 19
Vessel Inspection - Approved Inspection
6549008
New Orleans, Louisiana
Sep 26, 18
Vessel Inspection - Administrative Action
6521473
Lake Charles, Louisiana
Aug 30, 18
Vessel Inspection - Approved Inspection
6403977
TEXAS CITY, Texas
May 04, 18
Vessel Inspection - Approved Inspection
6386899
CORPUS CHRISTI, Texas
Apr 06, 18
Vessel Inspection - Agency Action Complete
6265375
Houston, Texas
Sep 12, 17
Vessel Inspection - Approved Inspection
6221668
NEW HAVEN, Connecticut
Jul 26, 17
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Vapor Control Systems Design Flaw
Description Due Date Resolved Cargo high level deck alarm (audible and visual)not present on vessel. Vessel shall not load certain Annex II cargoes in the United States, as indicated in 46CFR153.409. Oct 25, 17 Yes
Resolved Date Resolution Sep 12, 17 Sector Houston Galveston received Class Documentation and revised Certificate of Fitness, removing applicable 33CFR153.409 cargoes, thus eliminating the requirement to have on deck high level alarms.
6125528
Houston, Texas
Apr 20, 17
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Vapor Control Systems Design Flaw
Description Due Date Resolved 1899 - OTHER (TANKERS) - When Table 1 refers to this section or requires a cargo to have closed gauging system, them cargo's containment system must have a high level alarm that can be seen and heard where cargo transfer is controlled and on the open deck. Vessel is not fitted with high level alarm on the open deck. 46CFR153.409(b) 40c - Vessel is fitted with operational overfill alarm on deck. Yes
Resolved Date Resolution Jul 27, 17 Deficiency was amended, due to the vessel not being able to correct deficiency prior to next U.S. port after sailing foreign. See Activity 6221668 for further details.
5934190
STATEN ISLAND, New York
Jul 08, 16
Vessel Inspection - Approved Inspection
5844631
New Orleans, Louisiana
Mar 31, 16
Vessel Inspection - Administrative Action
5754318
STATEN ISLAND, New York
Oct 30, 15
Vessel Inspection - Approved Inspection
5750191
STATEN ISLAND, New York
Oct 25, 15
Vessel Operational Control - Agency Action Complete
5108758
Seattle, Washington
Apr 28, 15
Vessel Inspection - Approved Inspection
Documents
Issued
Expires
Agency
Certificate of Compliance - Tank Vessel
July 15,2019
July 15,2021
USCGNY
Certificate of Fitness - Chemical Carrier
August 7,2017
October 18,2021
NKK
Classification Document
November 11,2016
October 18,2021
NKK
COC-TVE Renewal
July 15,2019
July 15,2021
USCGNY
International Certificate of Fitness - Chemical
November 11,2016
October 18,2021
NKK
International Load Line Certificate
November 11,2016
October 18,2021
NKK
International Oil Pollution Prevention Certificate
October 26,2017
October 18,2021
NKK
ISM - Document Of Compliance
December 4,2019
December 21,2024
NKK
ISM - Safety Management Certificate
October 13,2016
September 15,2021
NKK
Minimum Safe Manning Document
January 17,2014
NKK
SOLAS Cargo Ship Safety Construction Certificate
November 11,2016
October 18,2021
NKK
SOLAS Cargo Ship Safety Equipment Certificate
November 11,2016
October 18,2021
NKK
SOLAS Cargo Ship Safety Radio Certificate
November 11,2016
October 18,2021
NKK
Tonnage Certificate, International
October 19,2011
NKK