Vinjerac
Print Q88   
IMO/VIN Callsign Flag Service Year
9489194 9AA7771 CROATIA Tank Ship 2011
Activity# Port Date Activity - Description Deficiencies
7068902 STATEN ISLAND, New York Sep 30, 20 Boarding - Agency Action Complete
7065508 STATEN ISLAND, New York Sep 26, 20 Vessel Operational Control - Approved Inspection
6956433 New Orleans, Louisiana May 22, 20 Vessel Inspection - Approved Inspection
6638768 TEXAS CITY, Texas Mar 12, 19 Vessel Inspection - Approved Inspection
5959592 San Juan, Puerto Rico Aug 01, 16 Vessel Inspection - Approved Inspection
5942270 San Juan, Puerto Rico Jul 28, 16 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Fire FightingFiremans OutfitImproper/Lack of Maintenance
DescriptionDue DateResolved
The material condition of the two firesuits has started to peel/deteriorate in several areas, making suits not as protective to the personnel. 74SOLAS(2009) II-2/10.1 FSS CODE CHAPTER 3.2.1.1.1 17cJul 28, 16Yes
Resolved DateResolution
Aug 01, 16Vessel's master provided invoice and pictures of 02 new fire fighting suits.
5135571 Miami Beach, Florida May 26, 15 Vessel Inspection - Approved Inspection
4737590 Mobile, Alabama Oct 24, 13 Vessel Inspection - Approved Inspection
4718809 Mobile, Alabama Sep 21, 13 Vessel Inspection - Approved Inspection
4675686 Mobile, Alabama Aug 13, 13 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
46 CFR 153.409(b)&(d). Where Table I refers to 46 CFR 153.409, the cargo's containment system must have a high level alarm that can be seen and heard on the open deck. The vessel is certified to carry Table I cargoes that refer to 46 CFR 153.409 and does not have a high level alarm that is visible and audible on the open deck.Yes
Resolved DateResolution
Oct 24, 13USCG Examiner attended vessel to test alarms. High level alarm is now audible and visual on deck. Deficiency cleared from Act #4675686
SystemSubsystemCause
CommunicationsVisual Communication
DescriptionDue DateResolved
46 CFR 153.955. When transferring cargo while fast to a dock, the master shall ensure that the tankship displays a warning sign at the gangway. The warning sign shall be marked as described in 46 CFR 153.955. The warning sign was not present during the exam.Yes
Resolved DateResolution
Sep 21, 13Received photo of properly displayed warning sign in accordance with 46CFR153.955.
4411525 Houston, Texas Aug 15, 12 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel May 28,2015 May 28,2016 N/A
Certificate of Fitness - Chemical Carrier June 1,2014 October 25,2016 HR
Classification Document April 27,2017 October 25,2021 CRS
International Certificate of Fitness - Chemical May 7,2018 October 25,2021 CRS
International Load Line Certificate April 27,2017 October 25,2021 CRS
International Oil Pollution Prevention Certificate April 27,2017 October 25,2021 CRS
ISM - Document Of Compliance December 13,2017 January 22,2023 CRS
ISM - Safety Management Certificate January 11,2017 October 25,2021 CRS
Minimum Safe Manning Document March 23,2016 HR
SOLAS Cargo Ship Safety Construction Certificate April 27,2017 October 25,2021 CRS
SOLAS Cargo Ship Safety Equipment Certificate April 27,2017 October 25,2021 CRS
SOLAS Cargo Ship Safety Radio Certificate January 11,2017 October 25,2021 CRS
Tonnage Certificate, International October 17,2011 CRS