Print Q88   
IMO/VIN Callsign Flag Service Year
1189655 UNITED STATES Tank Barge 2006
Activity# Port Date Activity - Description Deficiencies
7442955 Portsmouth, Virginia May 03, 22 Vessel Inspection - Approved Inspection
7396202 Baltimore, Maryland Feb 15, 22 Vessel Inspection - Approved Inspection
7362335 Portsmouth, Virginia Dec 04, 21 Facility Transfer Monitor - Agency Action Complete
7154994 Baltimore, Maryland Mar 11, 21 Vessel Inspection - Approved Inspection
6930078 Baltimore, Maryland Mar 05, 20 Vessel Inspection - Approved Inspection
6718959 Baltimore, Maryland Jun 07, 19 Vessel Inspection - Approved Inspection
6427382 Baltimore, Maryland May 29, 18 Vessel Inspection - Approved Inspection
6160309 Baltimore, Maryland May 24, 17 Facility Transfer Monitor - Agency Action Complete
6188383 Baltimore, Maryland May 04, 17 Vessel Inspection - Approved Inspection
6116808 Baltimore, Maryland Apr 03, 17 Vessel Inspection - Approved Inspection
6099605 Baltimore, Maryland Mar 09, 17 Vessel Inspection - Approved Inspection
5931329 Baltimore, Maryland Jul 06, 16 Vessel Inspection - Approved Inspection
5867393 WASHINGTON, District of Columbia May 02, 16 Incident Investigation - Agency Action Complete
5819732 Jacksonville, Florida Feb 22, 16 Vessel Inspection - Approved Inspection
5109408 Savannah, Georgia Apr 23, 15 Vessel Inspection - Agency Action Complete
5090211 Savannah, Georgia Mar 25, 15 Vessel Inspection - Approved Inspection
4883893 Jacksonville, Florida Jun 17, 14 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
NavigationCollision/Grounding AvoidanceImproper Installation
DescriptionDue DateResolved
Prove proper operation of port navigation light.Jul 01, 14Yes
Resolved DateResolution
Jun 17, 14
SystemSubsystemCause
EngineeringFuel Oil Storage/Transfer SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Provide double clamps on hoses of vital systems throughout vessel engines. Replace chaffed hydraulic hose on bow thrusters.Jul 01, 14Yes
Resolved DateResolution
Jun 19, 14
SystemSubsystemCause
Deck/CargoCargo StowageImproper/Lack of Maintenance
DescriptionDue DateResolved
Renew damaged gasket along #3 cargo tank ullage opening.Yes
Resolved DateResolution
Jun 17, 14
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)Improper/Lack of Maintenance
DescriptionDue DateResolved
Repair/Renew port cargo pump engine guard bracket.Jul 01, 14Yes
Resolved DateResolution
Jun 19, 14
4816182 WASHINGTON, District of Columbia Mar 11, 14 Incident Investigation - Agency Action Complete
4814617 Jacksonville, Florida Mar 10, 14 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Make proper repairs IWO #6 starboard void side shell, transverse frame, and lonitudinals.Yes
Resolved DateResolution
Mar 14, 14Examined repairs and conducted NDT of side shell welds, all sat.
4713377 Savannah, Georgia Sep 12, 13 Vessel Inspection - Approved Inspection
4610550 Jacksonville, Florida Jun 04, 13 Vessel Inspection - Approved Inspection
4342859 Savannah, Georgia Jun 07, 12 Vessel Inspection - Approved Inspection
4272244 Jacksonville, Florida Apr 06, 12 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
ALL PV VALVES MUST BE BENCH TESTED.May 06, 12Yes
Resolved DateResolution
Jun 04, 12Received Test Cert
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
INSTALL A ACCESS LADDER IN THE FWD RAKE FOR ACCESS TO CONDUCT ISE OF THE HEADLOG AND FRAME 1. THE LADDER IS REQUIRED TO BE COMPLETED BY 15 JUN 2014 OR AT NEXT DRYDOCK FOR CAUSE.Jun 15, 14Yes
Resolved DateResolution
Aug 08, 12
SystemSubsystemCause
DocumentationMarkings/Placards
DescriptionDue DateResolved
WARNING SIGN MUST BE RENEWED OR REPLACED.May 06, 12Yes
Resolved DateResolution
Aug 08, 12Conversation with vessel rep.
4045293 Jacksonville, Florida Jun 15, 11 Vessel Inspection - Approved Inspection
4040380 Jacksonville, Florida Jun 14, 11 Vessel Inspection - Approved Inspection
3985698 Jacksonville, Florida Apr 13, 11 Enforcement - Agency Action Complete
3979199 Jacksonville, Florida Apr 05, 11 Enforcement - Agency Action Complete
3969741 WASHINGTON, District of Columbia Mar 22, 11 Incident Investigation - Agency Action Complete
3748311 Jacksonville, Florida May 25, 10 Vessel Inspection - Approved Inspection
3735629 Jacksonville, Florida May 11, 10 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
Crop and renew to original scantling from 6 inches forward of FR. 25 aft 14 ft. 6 in., the shear strake, by 92-1/2 inches high in way of STBD Void #5.Jul 11, 10Yes
Resolved DateResolution
Jun 04, 10Renewal as directed.
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
In STBD Void #5, crop and renew FR. 26 truss to original scantling.Jul 11, 10Yes
Resolved DateResolution
Jun 04, 10Renewed as required.
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
In STBD Void #5, crop and renew the horizontal flat plate stiffeners, 34 in. x 6 in. x 3/8 in., in way of FR. 25.Jul 11, 10Yes
Resolved DateResolution
Jun 04, 10Renewed as required.
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
In STBD Void #5, crop and renew the horizontal side shell stiffeners #3, 4, 5 and 6 from FR. 25 aft 14 feet to FR. 27. The stiffeners are to be 4 in. x 3 in. x 5/16 in. minimum.Jul 11, 10Yes
Resolved DateResolution
Jun 04, 10Renewed as required.
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
In STBD Void #5, in way of FR. 26, crop and renew the outboard 40 in. x 28 in. x 3/8 in. section of the transverse frame.Jul 11, 10Yes
Resolved DateResolution
Jun 04, 10Renewed as required.
3707081 Jacksonville, Florida Apr 02, 10 Vessel Inspection - Approved Inspection
3506505 Jacksonville, Florida Jun 17, 09 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational SafetyUnknown
DescriptionDue DateResolved
Install a personnel guard in way of the bow thruster drive shaft, or, provide signage outside the Bow Thruster Void that reads NO ENTRY PERMITTED WHEN BOW THRUSTER IS IN USE.Aug 18, 09Yes
Resolved DateResolution
Jun 17, 09Signage applied.
SystemSubsystemCause
EngineeringBilge Water Management SystemImproper Installation
DescriptionDue DateResolved
Remove the PVC bilge piping and the electric submersible bilge pump from the Bow Thruster Void.Jun 30, 09Yes
Resolved DateResolution
Jun 17, 09PVC piping and pump removed.
3398347 Jacksonville, Florida Jan 15, 09 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Crop and renew the port side , FR. 3, vertical stiffeners #3 and #4, from the bottom shell 6 in. x 4 in. x 3/8 in. x 32 in.Yes
Resolved DateResolution
Jan 16, 09Insert satisfactory.
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Crop and renew the port side slope sheet in way of FR. 2 and the side shell. Insert plate to be 12 inches aft of FR. 2 to 24 inches forward of FR. 2. The plate width to be 18 inches starting at the sideshell / slope sheet butt weld. Plate thickness to be not less than 1/2 inch.Yes
Resolved DateResolution
Jan 16, 09Insert satisfactory.
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Crop and renew the port side, FR. 3, bottom longs #3 and #4, from FR. 3 5 in. x 3 in. x 1/4 in. x 36 in. and the associated triangular bracket.Yes
Resolved DateResolution
Jan 16, 09Insert satisfactory.
3172197 Wilmington, North Carolina Mar 27, 08 Vessel Inspection - Approved Inspection
2927668 BATON ROUGE, Louisiana May 11, 07 Vessel Inspection - Approved Inspection
2937053 Louisville, Kentucky Mar 22, 07 Vessel Inspection - Agency Action Complete
2826044 Savannah, Georgia Nov 21, 06 Vessel Inspection - Agency Action Complete
2801605 Washington, District of Columbia Oct 16, 06 Vessel Inspection - Security Plan Approved by MSC
Documents Issued Expires Agency
CERTIFICATE OF DOCUMENTATION October 6,2021 October 31,2022 USCG
Certificate of Inspection March 9,2017 March 9,2022 USCG
Certificate of Inspection - Amended March 9,2017 March 9,2022 USCG