Gonsoulin 516
Print Q88   
IMO/VIN Callsign Flag Service Year
1226779 UNITED STATES Tank Barge 2010
Activity# Port Date Activity - Description Deficiencies
7017516 Houma, Louisiana Jul 27, 20 Vessel Inspection - Approved Inspection
7008864 Houma, Louisiana Jul 17, 20 Vessel Inspection - Approved Inspection
6810407 WASHINGTON, District of Columbia Sep 12, 19 Incident Investigation - Agency Action Complete
6593912 TEXAS CITY, Texas Dec 08, 18 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemDamaged By Earlier Event
DescriptionDue DateResolved
Barge is required to have a means to indicate visually the level of liquid in the cargo tank when the liquid is within a range of 1 meter of the top of the tank. Upon inspection, the 1 meter stick on the #2 starboard cargo tank was found to be broken and required replacement. Replace broken 1 meter stick with functional one.Dec 10, 18Yes
Resolved DateResolution
Dec 10, 18Broken 1 meter stick was replaced with spare onboard towing vessel.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemInvalid
DescriptionDue DateResolved
Vapor Collection System (VCS) piping is required to be fitted with a permanent stud projecting outward that is 0.5 inches in diameter and 1 inch long at the top of its vapor connection flange faces. Marine inspectors found the reducer on the port side VCS piping flange lacked the required stud. Remove the reducer on the port side VCS piping flange and replace reducer with one having the required permanently mounted stud.Dec 10, 18Yes
Resolved DateResolution
Dec 10, 18Reducer was removed and will be replaced with one having the required permanant stud.
6348609 Houma, Louisiana Jan 12, 18 Vessel Inspection - Approved Inspection
6045933 Vicksburg, Mississippi Nov 20, 16 Vessel Inspection - Approved Inspection
6045135 WASHINGTON, District of Columbia Nov 20, 16 Incident Investigation - Agency Action Complete
6034171 Houma, Louisiana Oct 20, 16 Vessel Inspection - Approved Inspection
5744178 Houma, Louisiana Oct 16, 15 Vessel Inspection - Approved Inspection
5030858 Houma, Louisiana Nov 05, 14 Vessel Inspection - Approved Inspection
4992874 WASHINGTON, District of Columbia Sep 22, 14 Incident Investigation - Agency Action Complete
4744014 Houston, Texas Oct 30, 13 Vessel Inspection - Approved Inspection
4743320 Houston, Texas Oct 29, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
Vessel required per PRIS to have p/v relieve at 1.5 psi. Current p/v installed on barge relieves at 2.5 psi. Prior to cargo ops replace p/v w/ correct psiNov 12, 13Yes
Resolved DateResolution
Oct 30, 13Verified vessel installed proper p/v valves IAW PRIS.
4672528 Mobile, Alabama Aug 01, 13 Vessel Inspection - Approved Inspection
4675499 WASHINGTON, District of Columbia Aug 01, 13 Incident Investigation - Agency Action Complete
4530286 NASHVILLE, Tennessee Feb 06, 13 Vessel Transfer Monitor - Agency Action Complete
4480061 Houma, Louisiana Sep 24, 12 Vessel Inspection - Approved Inspection
4166253 Houma, Louisiana Sep 09, 11 Vessel Inspection - Approved Inspection
4129911 WASHINGTON, District of Columbia Aug 20, 11 Incident Investigation - Agency Action Complete
3965663 Lake Charles, Louisiana Mar 16, 11 Facility Transfer Monitor - Agency Action Complete
3787487 Houma, Louisiana Apr 01, 10 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Cargo Authority Attachment May 3,2016 N/A
CERTIFICATE OF DOCUMENTATION July 30,2020 August 31,2021 USCG
Certificate of Inspection October 7,2010 October 7,2015 N/A
Certificate of Inspection - Amended October 7,2010 October 7,2015 N/A