Louisiana
Print Q88   
IMO/VIN Callsign Flag Service Year
1267671 WDI7481 UNITED STATES Tank Barge 2016
Activity# Port Date Activity - Description Deficiencies
7659266 Baltimore, Maryland Mar 29, 23 Vessel Inspection - Approved Inspection
7397126 Wilmington, North Carolina Feb 16, 22 Vessel Inspection - Approved Inspection
7383509 Baltimore, Maryland Jan 11, 22 Vessel Inspection - Approved Inspection
7117380 ST PETERSBURG, Florida Dec 29, 20 Vessel Inspection - Approved Inspection
7117380 Tampa, Florida Dec 29, 20 Vessel Inspection - Approved Inspection
6949346 New Orleans, Louisiana May 14, 20 Vessel Inspection - Approved Inspection
6853839 ST PETERSBURG, Florida Nov 12, 19 Vessel Inspection - Approved Inspection
6853839 Tampa, Florida Nov 12, 19 Vessel Inspection - Approved Inspection
6618682 ST PETERSBURG, Florida Feb 01, 19 Vessel Inspection - Approved Inspection
6618682 Tampa, Florida Feb 01, 19 Vessel Inspection - Approved Inspection
6420136 New Orleans, Louisiana May 19, 18 Vessel Inspection - Approved Inspection
6410953 Wilmington, North Carolina May 10, 18 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringLubricating Oil Service System
DescriptionDue DateResolved
Nonmetallic flexible hose in lube oil systems must be in accordance with SAE J1942. The three cargo pump engines have non-approved hoses on the "Puradyn" oil centrifuge; replace the hoses in question with an approved type hose.May 24, 18Yes
Resolved DateResolution
May 18, 18Vessel Rep sent photos of the repared hose to Sector New Orleans. Cleared Outstanding 835
6359814 CORPUS CHRISTI, Texas Feb 23, 18 Vessel Inspection - Approved Inspection
6136558 New Orleans, Louisiana May 01, 17 Vessel Inspection - Approved Inspection
5940773 STURGEON BAY, Wisconsin Jul 01, 16 Vessel Inspection - Approved Inspection
5056681 STURGEON BAY, Wisconsin May 21, 14 Vessel Inspection - Approved Inspection
  11
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)Improper Installation
DescriptionDue DateResolved
Flexible fuel hoses are marked SAE J1527, not SAE J1942 per Sub F for the 2 large Gensets, & 3 cargo pump engines.Jun 16, 16Yes
Resolved DateResolution
May 19, 16Cleared 835 requirement after obtaining a copy of J1942 from MSC. All SAT.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Install plugs on the drain hole for the coamings around the stern fuel filling valve & teh black oily waste tank coaming.May 31, 16Yes
Resolved DateResolution
May 18, 16Plugs were installed.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Label all motor controllors and disconnect switches to their respective equipment.Jun 16, 16Yes
Resolved DateResolution
May 18, 16Electrical controllors & knife switches were marked.
SystemSubsystemCause
LifesavingLifebuoysImproper Installation
DescriptionDue DateResolved
Properly attach the waterlight to the ring buoy and install the correct batteries in the waterlight.May 31, 16Yes
Resolved DateResolution
May 18, 16Waterlight & throw bag were attached.
SystemSubsystemCause
Pollution Prevention/ResponseResponse Equipment
DescriptionDue DateResolved
Provide a pollution spill kit onboard the vessel.May 31, 16Yes
Resolved DateResolution
Jun 01, 16Pollution spill kit was verified
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Provide a valid COD.May 31, 16Yes
Resolved DateResolution
May 18, 16Vsl rep provided a copy of the COD, placed into vsl's documents.
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Provide a valid COFR.May 31, 16Yes
Resolved DateResolution
May 25, 16A valid COFR has been issued.
SystemSubsystemCause
EngineeringFuel Oil Service SystemImproper Installation
DescriptionDue DateResolved
Provide chafing gear on fuel return line for the in port/house genset, & secure the oil drain line from dangling inside the bilge of the genset.Jun 16, 16Yes
Resolved DateResolution
May 18, 16Fuel hose & oil drain line were secured.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Provide rubber matting in front & behind the main switchboard & the winch switchgear in the generator house.Jun 16, 16Yes
Resolved DateResolution
May 18, 16Matting installed, all Sat.
SystemSubsystemCause
Fire FightingFixed Fire Detection SystemInvalid
DescriptionDue DateResolved
Vsl to provide MSC approval for the fire detection system.Yes
Resolved DateResolution
May 24, 16Received MSC approval letter E2-1601947 for fire detection system
SystemSubsystemCause
Operations/ManagementCargo Transfer/LighteringInvalid
DescriptionDue DateResolved
Vsl's cargo loading/stability software system is under reivew with ABS; vsl to provide ABS approval for software system prior to use.Yes
Resolved DateResolution
Jun 01, 16Rcvd a copy of the ABS approval letter, dated 26May16 for the "CargoMax" loading software
Documents Issued Expires Agency
Cargo Authority Attachment December 21,2017 N/A
CERTIFICATE OF DOCUMENTATION December 8,2022 January 31,2024 USCG
Certificate of Inspection May 16,2016 May 16,2021 USCG
Certificate of Inspection - Amended May 16,2016 May 16,2021 N/A
Classification Document May 16,2016 October 15,2016 ABS
International Certificate of Fitness - Chemical May 16,2016 May 16,2021 N/A
International Load Line Certificate May 16,2016 October 15,2016 ABS
International Oil Pollution Prevention Certificate May 16,2016 October 15,2016 ABS
Int'l Oil Poll Prevention, Form B Supplement March 4,2019 March 4,2024 N/A
Stability Letter April 21,2016 ABS
Tonnage Certificate, International May 13,2016 ABS
Tonnage Certificate, U.S. May 13,2016 ABS