Chem Barcelona
Print Q88   
IMO/VIN Callsign Flag Service Year
9725835 D5KK6 LIBERIA Tank Ship 2016
Activity# Port Date Activity - Description Deficiencies
6858180 BOSTON, Massachusetts Nov 19, 19 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
01 - Certificates & Documentation013 - Documents
DescriptionDue DateResolved
The Master, Owner, Operator, Agent, or Person in Charge of a vessel bound for a port or place in the United States must ensure the maintenance of written or digital records that includes the information to be reported by 33CFR151.2060 of this subpart. Ballast Water Management Reports received by NBIC on 11SEP2019, 25SEP2019, and 30SEP2019 contain inaccurate location of the empty-refill exchange. Cite: 33CFR151.2070(a) Action Taken: 10cNov 19, 19Yes
Resolved DateResolution
Nov 19, 19
SystemSubsystemCause
99 - OtherN/A - No Subsystem
DescriptionDue DateResolved
To discharge ballast water into waters of the United States, the Master, Owner, Operator, Agent, or Person in Charge of a vessel subject to 33CFR151.2025 of this subpart must either ensure that the ballast water meets the Ballast Water Discharge Standard as defined in 33CFR151.2030(a), use an AMS as described in 33CFR151.2025(n)(3) or ballast exclusively with water from a U.S. public water system. On 18SEP2019, 24SEP2019, and 26SEP2019 the vessel discharged untreated ballast water into U.S. waters without using the approved Ballast Water Management System Cite: 33CFR151.2035(a) Action Taken: 10cNov 19, 19Yes
Resolved DateResolution
Nov 19, 19
6813759 Houston, Texas Sep 17, 19 Vessel Inspection - Approved Inspection
6796088 STATEN ISLAND, New York Aug 27, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
THE MASTER, OWNER, OPERATOR, OR PERSON IN CHARGE OF A VESSEL EQUIPPED WITH BALLAST TANKS THAT OPERATES ON THE NAVIGABLE WATERS OF THE U.S. MUST EMPLOY ONE OF THE FOLLOWING BALLAST WATER MANAGEMENT METHODS: INSTALL AND OPERATE A BALLAST WATER MANAGEMENT SYSTEM. VESSEL HAS ISNTALLED BWMS ONBOARD WHICH IN INOPERATIVE. VESSEL CAN NOT DISCHARGE BALLAST WATER IN THE U.S. UNTIL BWMS IS OPERABLE. 33CFR151.2025(a)(1) Action 15ac NPOC being Savannah, GA.Sep 03, 19Yes
Resolved DateResolution
Sep 17, 19REPAIRED BWTS AND CONDUCTED SATISFACTORY TEST.
6508736 Houston, Texas Aug 12, 18 Vessel Inspection - Approved Inspection
6413903 TEXAS CITY, Texas May 21, 18 Vessel Inspection - Approved Inspection
5969067 STATEN ISLAND, New York Aug 11, 16 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel May 21,2018 May 21,2020 N/A
Certificate of Fitness - Chemical Carrier February 16,2016 January 6,2021 NKK
Classification Document November 9,2017 January 6,2021 NKK
International Load Line Certificate February 16,2016 January 6,2021 NKK
International Oil Pollution Prevention Certificate February 16,2016 January 6,2021 NKK
ISM - Document Of Compliance May 19,2015 May 19,2020 N/A
ISM - Safety Management Certificate April 29,2017 April 28,2021 LR
Minimum Safe Manning Document November 9,2016 LR
SOLAS Cargo Ship Safety Construction Certificate February 16,2016 January 6,2021 NKK
SOLAS Cargo Ship Safety Equipment Certificate February 16,2016 January 6,2021 NKK
SOLAS Cargo Ship Safety Radio Certificate February 16,2016 January 6,2021 NKK
Tonnage Certificate, International January 7,2016 NKK