Pericles
Print Q88   
IMO/VIN Callsign Flag Service Year
9396488 5LBK7 LIBERIA Tank Ship 2007
Activity# Port Date Activity - Description Deficiencies
7279616 New Orleans, Louisiana Aug 15, 21 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemDamaged By Earlier Event
DescriptionDue DateResolved
For tankers of 20,000 tonnes deadweight and upwards, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the Fire Safety Systems Code. PSCO observed IG system not able to operate due to atmosphere purge valve failure. PSCO also observed crew attempting to electrically bypass the control at the purge valve actuator in an attempt to clear the common fault on the control panel, in order to force the system into operation. Vessel is restricted from conducting cargo operations of Annex I and II cargoes requiring inert gas. 74 SOLAs (14) II-2/4.5.5.1.1 40acNo
7189503 Houston, Texas May 05, 21 Vessel Inspection - Approved Inspection
7072286 Port Arthur, Texas Oct 08, 20 Vessel Inspection - Agency Action Complete
6909675 Mobile, Alabama Feb 15, 20 Vessel Inspection - Approved Inspection
6815611 New Orleans, Louisiana Sep 20, 19 Vessel Inspection - Approved Inspection
6559350 STATEN ISLAND, New York Oct 11, 18 Vessel Inspection - Agency Action Complete
6550462 STATEN ISLAND, New York Sep 28, 18 Vessel Operational Control - Agency Action Complete
6550647 WASHINGTON, District of Columbia Sep 28, 18 Incident Investigation - Agency Action Complete
6545863 STATEN ISLAND, New York Sep 21, 18 Vessel Operational Control - Agency Action Complete
6545538 STATEN ISLAND, New York Sep 21, 18 Vessel Inspection - Approved Inspection
  7
SystemSubsystemCause
03 - Water/Weathertight ConditionsN/A - No SubsystemInvalid
DescriptionDue DateResolved
Deck line shall be marked amidships on each side of the ship. Port side deckline is non-existent, it is not painted nor permanently marked. ICLL Reg 8Oct 21, 18Yes
Resolved DateResolution
Sep 22, 18Received class report attesting to repainting of port side deck line.
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemInvalid
DescriptionDue DateResolved
Doors required to be self-closing shall not be fitted with hold-back. Hold backs found and removed immediately. 74 SOLAS (2004) II-2/9.4.2.2Yes
Resolved DateResolution
Sep 21, 18
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemInvalid
DescriptionDue DateResolved
High Level alarm must be marked as described in 46CFR153.408(c)(6). High level signage is currently marked in red on white background.Oct 21, 18Yes
Resolved DateResolution
Sep 22, 18Received class report attesting to repainting of high level alarm lettering.
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Ship shall be maintained to proceed to sea without danger to persons on board. 1.) STBD bow mooring platform is wasted with temporary repair. 2.) STBD manifold platform top stair aft is wasted with temporary repair. 74 SOLAS (2004) I/11(a)Oct 21, 18Yes
Resolved DateResolution
Oct 11, 18RECEIVED CLASS REPORT ATTESTING TO PROPER REPAIRS, CLASS REPORT ATTACHED
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemInvalid
DescriptionDue DateResolved
Tank overflow must be identified with the legend "Tank Overflow Alarm" in lettering as specified for the warning sign in 46 CFR 153.955. Lettering is red on white background. 46 CFR 153.408(d)Oct 21, 18Yes
Resolved DateResolution
Sep 22, 18Received class report attesting to repainting of tank overflow alarm lettering.
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemInvalid
DescriptionDue DateResolved
The main steering gear and rudder stock shall be capable of putting the rudder over from 35 degrees on one side to 35 degrees on the other side. Steering gear on a single pump operation is incapable of traveling beyond 15 degrees port. 74 SOLAS (2004) II-1/29.3.2Yes
Resolved DateResolution
Sep 22, 18Received satisfactory class report attesting to the repairs of the steering gear.
SystemSubsystemCause
09 - Working and Living Conditions092 - Working ConditionsImproper/Lack of Maintenance
DescriptionDue DateResolved
The safety of passengers, crew and ship from electrical hazards will be ensured. Broken ground wire discovered STBD deck lighting. 74 SOLAS (2004) II-1/40.1.3Yes
Resolved DateResolution
Sep 21, 18
5108705 NEW HAVEN, Connecticut Apr 22, 15 Vessel Inspection - Approved Inspection
4507270 Savannah, Georgia Dec 27, 12 Vessel Inspection - Agency Action Complete
4499522 New Orleans, Louisiana Dec 12, 12 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
1730 - Oily water separating equipment- Filtering equipment shall be of a design approved by the administration. The 15ppm Bilge Alarm should record date, time and alarm status, The oil content meter records however, dates displayed are 11 months off the correct date. Marpol 73/78 Annex I/14, MEPC. 107(49)Dec 22, 12Yes
Resolved DateResolution
Dec 24, 12Recieved Class Report attesting to repairs.
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
The inert gas system shall be designed, constructed and tested in accordance with the Fire Safety System Code. Instrumentation shall be fitted for continuously indicating and permanently recording. Alarm/control panel in CCR does not properly indicate oxygen content. Vessel is prohibited from conducting cargo which requires inert gas. SOLAS 74 (a) II-2/4, FSS CH 15Dec 12, 12Yes
Resolved DateResolution
Dec 24, 12Recieved Class Report attesting to repairs
4065273 Houston, Texas Jul 02, 11 Vessel Inspection - Approved Inspection
3819171 STATEN ISLAND, New York Aug 09, 10 Vessel Inspection - Agency Action Complete
3739607 Houston, Texas May 16, 10 Vessel Inspection - Approved Inspection
3562616 CAPE MAY, New Jersey Aug 10, 09 Boarding - Agency Action Complete
3545471 Houston, Texas Jul 25, 09 Vessel Inspection - Approved Inspection
3337319 Christiansted, Virgin Islands Oct 02, 08 Vessel Inspection - Administrative Action
3245968 Houston, Texas Jun 23, 08 Vessel Operational Control - Approved Inspection
  1
SystemSubsystemCause
CommunicationsAlarms/Indicators
DescriptionDue DateResolved
23 Jun: Vessel suffered temporary loss of steering during I/B transit to Houston. Issued OPCON, require class report prior to departure from Port of Houston.Jun 23, 08Yes
Resolved DateResolution
Jun 24, 08Received satisfactory class report. System was function tested and visually inspected by surveyor with no defects noted. See narrative
3191886 STATEN ISLAND, New York Apr 25, 08 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel September 20,2019 September 20,2020 N/A
Certificate of Fitness - Chemical Carrier March 14,2013 November 30,2017 ABS
Classification Document May 23,2013 November 30,2017 ABS
International Certificate of Fitness - Chemical February 4,2009 November 30,2012 ABS
International Load Line Certificate April 3,2008 November 30,2012 DNV
International Oil Pollution Prevention Certificate January 21,2014 November 30,2017 ABS
ISM - Document Of Compliance July 13,2011 June 14,2016 ABS
ISM - Safety Management Certificate November 2,2012 May 1,2013 ABS
Minimum Safe Manning Document August 7,2018 MH
SOLAS Cargo Ship Safety Construction Certificate March 14,2013 November 30,2017 ABS
SOLAS Cargo Ship Safety Equipment Certificate March 14,2013 November 30,2017 ABS
SOLAS Cargo Ship Safety Radio Certificate March 14,2013 November 30,2017 ABS
Tonnage Certificate, International August 27,2018 ABS