Activity# Port Date Activity - Description Deficiencies
7480123 San Pedro, California Jun 17, 22 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
IN TANKERS, ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED SILICONE AROUND THE DECK WATER SEAL LOW LEVEL ALARM HOUSING AND WIRING COMPONENTS. 74 SOLAS (14) II-1.45.11Yes
Resolved DateResolution
Jun 18, 22Tech report recieved attesting to sufficient repair
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemInvalid
DescriptionDue DateResolved
THE INERT GAS SYSTEM REFERRED TO IN PARAGRAPH 5.5.3.1 SHALL BE DESIGNED, CONSTRUCTED AND TESTED IN ACCORDANCE WITH THE FIRE SAFETY SYSTEM CODE. PSCO OBSERVED PIN HOLE LEAK ON IGG SCRUBBER SPRINKLER SYSTEM. PIN HOLE LEAK IS LOCATED ON THE WATER SUPPLY LINE (200A/8"), BETWEEN THE IGG COOL S.W. PUMP AND VALVE V-307. 74 SOLAS (14) II-2 4.5.5.3.1Yes
Resolved DateResolution
Jun 18, 22Tech report provided attesting to sufficient repair of water supply line
7122151 Houston, Texas Jan 10, 21 Vessel Inspection - Agency Action Complete
7122150 Houston, Texas Jan 08, 21 Boarding - Agency Action Complete
6938961 Seattle, Washington Apr 14, 20 Vessel Inspection - Administrative Action
6934024 San Francisco, California Apr 01, 20 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
General arrangement plans shall be permanently exhibited for the guidance of the ships officers showing clearly for each deck the various fore sections enclosed by A class divisions. The fire control plans did not clearly show A class divisions. 74 SOLAS (14) II-2/15.2.4.1 50a/cApr 30, 20Yes
Resolved DateResolution
Apr 05, 20Fire Control Plan was replaced with spare Fire Control Plan.
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
The inert gas system referred to in paragraph 5.5.3.1 shall be designed, constructed and tested in accordance with the Fire Safety System Code. PSCO observed pin hole leak on IGG scrubber sprinkler system, and unsecured leaking sight glass on PV breaker. 74 SOLAS (14) II-2/4.5.5.3.1 50a/cApr 30, 20Yes
Resolved DateResolution
Apr 05, 20End plate of sprinkler manifold was renewed. Repairs were checked during IGG operation with normal working pressure and found satisfactory. Sight glass of PV breaker was repaired.
6528900 New Orleans, Louisiana Sep 04, 18 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No SubsystemPlaced in Improper Service
DescriptionDue DateResolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. P/S lifeboat supplied air relief valve not correctly set and not holding pressure. STBD lifeboat air regulating valve not properly set according to manufacture instructions. PSCO unable to verify accuracy of 10 minute air supply as adjusted by crew. SOLAS 74 a (2014 Cons) III/20.2 16aYes
Resolved DateResolution
Sep 07, 18Received, reviewed and accepted class report from LR stating the deficiency was rectified. Relief valve correctly set and holding pressure, air regulating valve set to .6 to .8 MPA as per manufacturer w/instructions posted.
6246284 New Orleans, Louisiana Aug 20, 17 Vessel Inspection - Agency Action Complete
6247567 WASHINGTON, District of Columbia Aug 20, 17 Incident Investigation - Agency Action Complete
6223427 Houston, Texas Aug 03, 17 Vessel Inspection - Approved Inspection
5922829 CORPUS CHRISTI, Texas Jul 06, 16 Vessel Inspection - Approved Inspection
5928997 PORT ARANSAS, Texas Jul 02, 16 Boarding - Agency Action Complete
5925965 CORPUS CHRISTI, Texas Jul 01, 16 Vessel Operational Control - Agency Action Complete
5075107 Wilmington, North Carolina Feb 26, 15 Vessel Inspection - Approved Inspection
5004693 Houston, Texas Oct 16, 14 Vessel Inspection - Approved Inspection
4734940 Port Arthur, Texas Oct 18, 13 Vessel Inspection - Approved Inspection
3732183 New Orleans, Louisiana May 12, 10 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Fitness - Chemical Carrier November 24,2014 September 29,2019 LR
Classification Document November 24,2014 September 29,2019 LR
COC-TVE Renewal May 12,2010 May 12,2012 NEWMS
International Certificate of Fitness - Chemical April 20,2010 September 29,2014 LR
International Load Line Certificate October 19,2019 September 29,2024 LR
International Oil Pollution Prevention Certificate June 18,2020 September 29,2024 LR
ISM - Document Of Compliance May 4,2016 June 14,2021 ABS
ISM - Safety Management Certificate February 18,2010 July 17,2010 LR
Minimum Safe Manning Document September 30,2009 MH
SOLAS Cargo Ship Safety Construction Certificate January 7,2020 September 29,2024 LR
SOLAS Cargo Ship Safety Equipment Certificate September 16,2015 September 29,2019 LR
SOLAS Cargo Ship Safety Radio Certificate August 13,2014 September 29,2019 LR
Tonnage Certificate, International July 30,2009 LR