IMO/VIN
Callsign
Flag
Service
Year
9418145
V7SL8
MARSHALL ISLANDS
Tank Ship
2009
Activity#
Port
Date
Activity - Description
Deficiencies
7480123
San Pedro, California
Jun 17, 22
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause 02 - Structural Conditions N/A - No Subsystem Improper/Lack of Maintenance
Description Due Date Resolved IN TANKERS, ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED SILICONE AROUND THE DECK WATER SEAL LOW LEVEL ALARM HOUSING AND WIRING COMPONENTS.
74 SOLAS (14) II-1.45.11 Yes
Resolved Date Resolution Jun 18, 22 Tech report recieved attesting to sufficient repair
System Subsystem Cause 07 - Fire Safety N/A - No Subsystem Invalid
Description Due Date Resolved THE INERT GAS SYSTEM REFERRED TO IN PARAGRAPH 5.5.3.1 SHALL BE DESIGNED, CONSTRUCTED AND TESTED IN ACCORDANCE WITH THE FIRE SAFETY SYSTEM CODE. PSCO OBSERVED PIN HOLE LEAK ON IGG SCRUBBER SPRINKLER SYSTEM. PIN HOLE LEAK IS LOCATED ON THE WATER SUPPLY LINE (200A/8"), BETWEEN THE IGG COOL S.W. PUMP AND VALVE V-307.
74 SOLAS (14) II-2 4.5.5.3.1 Yes
Resolved Date Resolution Jun 18, 22 Tech report provided attesting to sufficient repair of water supply line
7122151
Houston, Texas
Jan 10, 21
Vessel Inspection - Agency Action Complete
7122150
Houston, Texas
Jan 08, 21
Boarding - Agency Action Complete
6938961
Seattle, Washington
Apr 14, 20
Vessel Inspection - Administrative Action
6934024
San Francisco, California
Apr 01, 20
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause 07 - Fire Safety N/A - No Subsystem
Description Due Date Resolved General arrangement plans shall be permanently exhibited for the guidance of the ships officers showing clearly for each deck the various fore sections enclosed by A class divisions. The fire control plans did not clearly show A class divisions.
74 SOLAS (14) II-2/15.2.4.1
50a/c Apr 30, 20 Yes
Resolved Date Resolution Apr 05, 20 Fire Control Plan was replaced with spare Fire Control Plan.
System Subsystem Cause 07 - Fire Safety N/A - No Subsystem
Description Due Date Resolved The inert gas system referred to in paragraph 5.5.3.1 shall be designed, constructed and tested in accordance with the Fire Safety System Code. PSCO observed pin hole leak on IGG scrubber sprinkler system, and unsecured leaking sight glass on PV breaker.
74 SOLAS (14) II-2/4.5.5.3.1
50a/c Apr 30, 20 Yes
Resolved Date Resolution Apr 05, 20 End plate of sprinkler manifold was renewed. Repairs were checked during IGG operation with normal working pressure and found satisfactory. Sight glass of PV breaker was repaired.
6528900
New Orleans, Louisiana
Sep 04, 18
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 11 - Life Saving Appliances N/A - No Subsystem Placed in Improper Service
Description Due Date Resolved Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. P/S lifeboat supplied air relief valve not correctly set and not holding pressure. STBD lifeboat air regulating valve not properly set according to manufacture instructions. PSCO unable to verify accuracy of 10 minute air supply as adjusted by crew.
SOLAS 74 a (2014 Cons) III/20.2 16a Yes
Resolved Date Resolution Sep 07, 18 Received, reviewed and accepted class report from LR stating the deficiency was rectified. Relief valve correctly set and holding pressure, air regulating valve set to .6 to .8 MPA as per manufacturer w/instructions posted.
6246284
New Orleans, Louisiana
Aug 20, 17
Vessel Inspection - Agency Action Complete
6247567
WASHINGTON, District of Columbia
Aug 20, 17
Incident Investigation - Agency Action Complete
6223427
Houston, Texas
Aug 03, 17
Vessel Inspection - Approved Inspection
5922829
CORPUS CHRISTI, Texas
Jul 06, 16
Vessel Inspection - Approved Inspection
5928997
PORT ARANSAS, Texas
Jul 02, 16
Boarding - Agency Action Complete
5925965
CORPUS CHRISTI, Texas
Jul 01, 16
Vessel Operational Control - Agency Action Complete
5075107
Wilmington, North Carolina
Feb 26, 15
Vessel Inspection - Approved Inspection
5004693
Houston, Texas
Oct 16, 14
Vessel Inspection - Approved Inspection
4734940
Port Arthur, Texas
Oct 18, 13
Vessel Inspection - Approved Inspection
3732183
New Orleans, Louisiana
May 12, 10
Vessel Inspection - Approved Inspection
Documents
Issued
Expires
Agency
Certificate of Fitness - Chemical Carrier
November 24,2014
September 29,2019
LR
Classification Document
November 24,2014
September 29,2019
LR
COC-TVE Renewal
May 12,2010
May 12,2012
NEWMS
International Certificate of Fitness - Chemical
April 20,2010
September 29,2014
LR
International Load Line Certificate
October 19,2019
September 29,2024
LR
International Oil Pollution Prevention Certificate
June 18,2020
September 29,2024
LR
ISM - Document Of Compliance
May 4,2016
June 14,2021
ABS
ISM - Safety Management Certificate
February 18,2010
July 17,2010
LR
Minimum Safe Manning Document
September 30,2009
MH
SOLAS Cargo Ship Safety Construction Certificate
January 7,2020
September 29,2024
LR
SOLAS Cargo Ship Safety Equipment Certificate
September 16,2015
September 29,2019
LR
SOLAS Cargo Ship Safety Radio Certificate
August 13,2014
September 29,2019
LR
Tonnage Certificate, International
July 30,2009
LR