Miss Marina
Print Q88   
IMO/VIN Callsign Flag Service Year
9528380 9HA2820 MALTA Tank Ship 2011
Activity# Port Date Activity - Description Deficiencies
6664688 Houston, Texas Apr 17, 19 Vessel Inspection - Approved Inspection
6643272 Houston, Texas Apr 01, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
01 - Certificates & Documentation011 - Ships Certificates
DescriptionDue DateResolved
An International Certificate of Fitness for the carriage of Dangerous Chemicals in Bulk shall be issued. Such a certificate shall be drawn up in the form corresponding to the model given in the appendix. The form for the COF in the appendix lists section 6.1 as "only in accordance with loading conditions verified compliant with intact and damage stability requirements using the approved stability instrument fitted in accordance with paragraph 2.2.6 of the Code." Vessel's COF, certificate No. 87618-V021-014A, issued 11AUG2016 (after applicability of stability instrument requirement in IBC 2.2.6) has section 6.1 as "only in accordance with the loading conditions provided in the approved loading manual, stamped and dated 08APR2011 and signed by a responsible officer in the RINA." Vessel's COF is in the incorrect form and does not attest to the ship having a stability instrument that meets IBC 2.2.6. 74 SOLAS (14) VII/10.1 REF IBC 1.5.4 50acMay 01, 19Yes
Resolved DateResolution
Apr 17, 19SEC HOU GAL RECIEVED SATISFACTORY DOCUMENTATION FROM RINA TO CLOSE THE DEFICIENCY.
6363300 Mobile, Alabama Feb 28, 18 Vessel Inspection - Approved Inspection
6359508 Mobile, Alabama Feb 27, 18 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Construction/LoadlineMarkingsInvalid
DescriptionDue DateResolved
Code 0120 The International Load Line Certificate (1966) shall not be delivered to the ship until the officer or surveyor acting under the provisions of article 13 of the present convention has certified that the marks are correctly and permanently indicated on the ships sides. PSCO noted the Load line markings on the sides of the ship do not match the issued Load Line Certificate. ICLL Ch.1 Reg 9 Action taken 17acYes
Resolved DateResolution
Feb 28, 18PSCO noted the correct loadline was marked on the sides of the ship to match the current Load Line Certificate which was certified by the classification society RINA.
6026595 STATEN ISLAND, New York Oct 21, 16 Vessel Inspection - Approved Inspection
5790421 BOSTON, Massachusetts Jan 04, 16 Vessel Inspection - Approved Inspection
5786365 Woods Hole, Massachusetts Dec 23, 15 Vessel Inspection - Agency Action Complete
5780617 BOSTON, Massachusetts Dec 13, 15 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
DocumentationCertificates/DocumentsDesign Flaw
DescriptionDue DateResolved
0120- Load Lines shall be permanently marked on the sides of the ship to the satisfaction of the administration. The load line is not marked in accordance with the ILLC.Jan 04, 16Yes
Resolved DateResolution
Dec 27, 15The Load Line was corrected in accordance with the ILLC. Pictures were provided to Sector Boston.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention EquipmentInvalid
DescriptionDue DateResolved
1740- The administration shall have regard to the specification recommendedby the organization. The calibration seal on the oil content meter is broken making it void. Resolution (MEPC.107(49)Jan 04, 16Yes
Resolved DateResolution
Dec 27, 15Received class report attesting to the calibration of the OCM.
4998234 Miami Beach, Florida Oct 03, 14 Vessel Inspection - Administrative Action
4997417 Miami Beach, Florida Oct 02, 14 Vessel Inspection - Approved Inspection
4545477 STATEN ISLAND, New York Mar 09, 13 Vessel Inspection - Approved Inspection
4331052 Brownsville, Texas Jun 01, 12 Vessel Inspection - Approved Inspection
4189960 Brownsville, Texas Nov 16, 11 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Operations/ManagementEPA Vessel General Permit (VGP)
DescriptionDue DateResolved
Vessel is required to maintain a vessel general permit and submit a Notice of intent. A vessel general permit is not provided on board nor is there evidence that a Notice of Intent has been submitted.Yes
Resolved DateResolution
Jun 01, 12Verified vessel has submitted an NOI and currently maintains a VGP on board. (verified via e-mail)
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel October 6,2014 October 6,2016 N/A
Certificate of Fitness - Chemical Carrier August 10,2011 July 25,2016 N/A
Classification Document August 11,2016 July 25,2021 RINA
International Certificate of Fitness - Chemical August 11,2016 July 25,2021 RINA
International Load Line Certificate August 11,2016 July 25,2021 RINA
International Oil Pollution Prevention Certificate August 11,2016 July 25,2021 RINA
ISM - Document Of Compliance June 19,2017 March 23,2022 RINA
ISM - Safety Management Certificate March 21,2017 January 6,2022 RINA
Minimum Safe Manning Document July 11,2016 July 24,2021 MT
SOLAS Cargo Ship Safety Construction Certificate August 11,2016 July 25,2021 RINA
SOLAS Cargo Ship Safety Equipment Certificate August 11,2016 July 25,2021 RINA
SOLAS Cargo Ship Safety Radio Certificate August 11,2016 July 25,2021 RINA
Tonnage Certificate, International May 3,2012 MT