IMO/VIN
Callsign
Flag
Service
Year
9256248
V7PN8
MARSHALL ISLANDS
Tank Ship
2003
Activity#
Port
Date
Activity - Description
Deficiencies
6434643
Christiansted, Virgin Islands
Jun 05, 18
Vessel Inspection - Agency Action Complete
6354231
Christiansted, Virgin Islands
Feb 21, 18
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Inert Gas System Improper/Lack of Maintenance
Description Due Date Resolved 1830- The inert gas system shall be designed to the satisfaction of the Administration. The Deck water Seal Float switch is not operating as designed in accordance with the IGS manual chapter 12 Section 1.48.10 D.W.S low water level switch.74 SOLAS(2004 Cons Ed) II-2/5.5.1.1 FSS Code Ch 15.2.1.2 - Action Taken 40AC Yes
Resolved Date Resolution Jun 05, 18 Vessel provided Class report From Lloyds. Reference the attached report attesting to proper operation of the DWS.
6072749
CORPUS CHRISTI, Texas
Jan 24, 17
Vessel Inspection - Approved Inspection
5968536
New Orleans, Louisiana
Aug 10, 16
Vessel Inspection - Agency Action Complete
5800412
Houston, Texas
Jan 24, 16
Vessel Inspection - Approved Inspection
5097718
TEXAS CITY, Texas
Apr 01, 15
Vessel Inspection - Approved Inspection
5093628
TEXAS CITY, Texas
Mar 31, 15
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Your vessel was involved in a marine casualty (grounding) at 29* 04.863 N/094* 15.891 W. Satisfactory flag/class survey must take place. 74SOLAS09 I/Reg 11a Yes
Resolved Date Resolution Apr 01, 15 Received survey report from class resulting from grounding.
5042951
Lewes, Delaware
Dec 22, 14
Vessel Inspection - Approved Inspection
4779658
CORPUS CHRISTI, Texas
Jan 09, 14
Vessel Inspection - Approved Inspection
4765777
TEXAS CITY, Texas
Dec 19, 13
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Operations/Management Vessel Safety Management Improper/Lack of Maintenance
Description Due Date Resolved After any survey of the ship has been completed no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey without the sanction of the administration. The seawater overboard cooling line was found to have temp repairs due to wastage. Yes
Resolved Date Resolution Dec 21, 13 Received class report attesting to proper repairs.
System Subsystem Cause Operations/Management Vessel Safety Management Improper/Lack of Maintenance
Description Due Date Resolved After any survey of the ship has been completed no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey without the sanction of the administration. Exhaust inlext pipe to scrubber was found to have a temp repair due to wastage. Yes
Resolved Date Resolution Dec 20, 13 Permanent repairs made to the satisfaction of class. Conducted satisfactory test of the IGS.
4732591
San Pedro, California
Oct 10, 13
Vessel Operational Control - Agency Action Complete
1
0
System Subsystem Cause Navigation Piloting/Steering
Description Due Date Resolved USCG Port State Control has issued a inbound Letter of deviation to T/V SN FEDERICA for a malfunctioning Gyro Compass on 09 OCT 2013. Oct 10, 13 Yes
Resolved Date Resolution Oct 10, 13 Class report received, reviewed and accepted. LOD has been cleared.
4684042
San Diego, California
Aug 13, 13
Vessel Inspection - Approved Inspection
4517928
New Orleans, Louisiana
Jan 22, 13
Vessel Inspection - Approved Inspection
4502989
San Pedro, California
Dec 20, 12
Vessel Inspection - Agency Action Complete
2
0
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved 1840: Suitable means shall be provided for the zero callibration of fixed O2 meter for IG. Crew could not demonstrate zero of sensor. SOLAS 74 (2001 cond ed) ChII-2 Reg 62.18. Yes
Resolved Date Resolution Jan 22, 13 Received, reviewed, accepted tech report from QCC-Panama stating the deficiency has been rectified. Report states O2 analyzer has been calibrated as per manufacturer’s instructions.
System Subsystem Cause Deck/Cargo Inert Gas System
Description Due Date Resolved 1899: Special consideration shall be made to prevent flue gas leakages into enclosed spaces. Alteration of a drain fitting on both blowers failed allowing free communication of flue gas into IG flat. SOLAS 74 (2001 Cond) Ch II-2 Reg 62.8.1. Dec 20, 12 Yes
Resolved Date Resolution Dec 20, 12 Fitting removed and drain line capped.
4468921
San Pedro, California
Oct 23, 12
Vessel Inspection - Agency Action Complete
4304362
San Francisco, California
May 07, 12
Vessel Inspection - Approved Inspection
4303783
San Francisco, California
May 07, 12
Vessel Operational Control - Agency Action Complete
4304517
WASHINGTON, District of Columbia
May 06, 12
Incident Investigation - Agency Action Complete
4301157
San Pedro, California
May 03, 12
Vessel Inspection - Agency Action Complete
4204045
FPO, AP, Guam
Dec 11, 11
Vessel Inspection - Approved Inspection
4202304
FPO, AP, Guam
Dec 09, 11
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Deck/Cargo Inert Gas System Invalid
Description Due Date Resolved IGS line expansion joint compromised (leaking flue gas) with a tear along starboard side. Dec 11, 11 Yes
Resolved Date Resolution May 03, 12 IGS line expansion on the port side weather deck has been replaced.
System Subsystem Cause Navigation Collision/Grounding Avoidance Invalid
Description Due Date Resolved Monitor for the X-Band Radar is malfunctioning rendering radar inoperable. Attending technician was unable to repair inoperable monitor will receive new equipment at next U.S. Port. Dec 11, 11 Yes
Resolved Date Resolution May 03, 12 Deficiency was cleared as per tech report.
4204059
FPO, AP, Guam
Dec 08, 11
Vessel Operational Control - Agency Action Complete
3870646
New Orleans, Louisiana
Oct 15, 10
Vessel Operational Control - Agency Action Complete
3872559
New Orleans, Louisiana
Oct 15, 10
Vessel Inspection - Administrative Action
1
0
System Subsystem Cause Engineering Diesel Engine (propulsion-direct drive)
Description Due Date Resolved The vessel experienced a Propulsion Irregularity while in the Mississippi River due to the fuel pump pneumatic control for the #2 cylinder vibrating loose. Oct 15, 10 Yes
Resolved Date Resolution Oct 15, 10 Received, reviewed and accepted class report from RINA stating the pump pneumatic control was tightened, tested and found satisfactory.
3872037
WASHINGTON, District of Columbia
Oct 15, 10
Incident Investigation - Agency Action Complete
3794729
STATEN ISLAND, New York
Jul 13, 10
Vessel Operational Control - Agency Action Complete
3782083
New Orleans, Louisiana
Jul 01, 10
Vessel Inspection - Administrative Action
1
0
System Subsystem Cause Navigation Piloting/Steering
Description Due Date Resolved The Gyro Compass was reported not operational. Jul 01, 10 Yes
Resolved Date Resolution Jul 01, 10 Received, reviewed and accepted technician report from Sperry Marine stating the gyro compass was repaired, tested and found satisfactory.
3716346
Coram, New York
Apr 13, 10
Vessel Inspection - Approved Inspection
3678327
STATEN ISLAND, New York
Feb 10, 10
Vessel Operational Control - Agency Action Complete
3649321
TEXAS CITY, Texas
Dec 17, 09
Vessel Inspection - Approved Inspection
3596695
New Orleans, Louisiana
Sep 17, 09
Vessel Inspection - Administrative Action
3474224
New Orleans, Louisiana
May 13, 09
Vessel Operational Control - Agency Action Complete
3474379
New Orleans, Louisiana
May 13, 09
Vessel Inspection - Administrative Action
1
0
System Subsystem Cause Engineering Fuel Oil Service System
Description Due Date Resolved Received class report stating that the Fuel pump gear including Fuel Pump Roller Guide and Link for reversing had suffered damage. May 13, 09 Yes
Resolved Date Resolution May 17, 09 Received class report stating that repairs were made and the Main Engine was tested satisfactorily in both ahead and astern modes.
3427057
STATEN ISLAND, New York
Mar 03, 09
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Deck/Cargo Inert Gas System Unknown
Description Due Date Resolved Vessel is to permanently repair burst steam inlet pipe in way of deck seal heating coil, Vessels SMS procedures state heating system must be operating when temperatures are below 0 degrees Celsius, Class to attend vessel on 04 March 2009 and approve repairs. Mar 04, 09 Yes
Resolved Date Resolution Mar 05, 09 Received report from class attesting to the temporary repair of the steam line, condition of class issued, deficiency cleared.
System Subsystem Cause Engineering Fuel Oil Service System Unknown
Description Due Date Resolved Vessel's #1 booster pump seal is to be replaced to the satisfaction of class, additionally the surrounding area in the fuel oil purifying room shall be cleaned to satisfaction of class. Apr 04, 09 Yes
Resolved Date Resolution May 12, 09 Received Class Report from ABS stating that the seal on the Fuel Oil Booster Pump was replaced. Pump was tried out and found satisfactory.
3425220
Jacksonville, Florida
Feb 27, 09
Vessel Inspection - Agency Action Complete
3399094
New Orleans, Louisiana
Jan 23, 09
Vessel Inspection - Administrative Action
3322739
Wilmington, North Carolina
Sep 11, 08
Vessel Inspection - Agency Action Complete
3267681
New Orleans, Louisiana
Jul 14, 08
Vessel Inspection - Approved Inspection
3155353
CORPUS CHRISTI, Texas
Mar 03, 08
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Fire Fighting Firemans Outfit
Description Due Date Resolved Firemans outfit was torn and delaminated, not serviceable. Three remain in good condition. Solas 2004 Cons ed. II-2 Reg. 10.2.3 Yes
Resolved Date Resolution Mar 04, 08 Receipt of fireman outfit.
3092402
New Orleans, Louisiana
Nov 03, 07
Vessel Inspection - Administrative Action
3008728
San Juan, Puerto Rico
Jul 27, 07
Vessel Inspection - Approved Inspection
2910848
Christiansted, Virgin Islands
Apr 19, 07
Vessel Inspection - Approved Inspection
2873733
Christiansted, Virgin Islands
Feb 18, 07
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Lifesaving Visual Distress Signals (General)
Description Due Date Resolved Properly service EPIRB. EPIRB battery has expired. Yes
Resolved Date Resolution Feb 26, 07 Received invoice from agent via fax attesting satisfactory replacment of the EPIRB.
2592900
San Francisco, California
Feb 27, 06
Boarding - Agency Action Complete
2592514
San Francisco, California
Feb 27, 06
Vessel Inspection - Approved Inspection
2553307
Houston, Texas
Dec 18, 05
Vessel Operational Control - Agency Action Complete
1
0
System Subsystem Cause Stability Watertight Integrity
Description Due Date Resolved 17DEC05 Vessel grounded in the Galveston Bay. Operational control was issued requiring the vessel to have an hull survey, locating any damage to the satisfaction of the vessel's Class Society prior to entry into the Port of Houston-Galveston and report findings to local COTP. Yes
Resolved Date Resolution Dec 17, 05 17DEC05 received Classification Survey Report confirming vessel''''s structural integrity and sea worthiness. Vessel released by operational control on 17DEC05. 1 def. issued, 1 def cleared.
2552638
Houston, Texas
Dec 16, 05
Vessel Inspection - Agency Action Complete
2562010
WASHINGTON, District of Columbia
Dec 16, 05
Incident Investigation - Agency Action Complete
2405903
San Pedro, California
Jun 27, 05
Boarding - Agency Action Complete
2306853
Houston, Texas
Mar 08, 05
Boarding - Approved Inspection
2265047
San Francisco, California
Dec 27, 04
Vessel Inspection - Approved Inspection
2127118
San Francisco, California
Jul 09, 04
Vessel Inspection - Approved Inspection
2039140
CORPUS CHRISTI, Texas
Apr 07, 04
Boarding - Agency Action Complete
2037575
CORPUS CHRISTI, Texas
Apr 05, 04
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause Deck/Cargo Inert Gas System
Description Due Date Resolved IGS blower removed from vessel for repairs. Vessel required to class verify proper repair and installation of IGS blower.
SOLAS 74 Ammend CH II-2 reg 62 LEGACY COMPONENT DESC: blower Apr 06, 04 Yes
Resolved Date Resolution Apr 08, 04 Rcvd class report verifing repairs.
2008508
CORPUS CHRISTI, Texas
Feb 18, 04
Vessel Inspection - Agency Action Complete
1981696
STATEN ISLAND, New York
Jan 12, 04
Vessel Inspection - Agency Action Complete
1981309
STATEN ISLAND, New York
Jan 11, 04
Vessel Inspection - Agency Action Complete
Documents
Issued
Expires
Agency
Certificate of Compliance - Tank Vessel
January 11,2004
January 11,2005
N/A
Classification Document
April 21,2003
January 31,2004
RINA
COC-TVE Annual
March 4,2009
March 3,2010
USCG
COC-TVE Renewal
March 3,2008
March 3,2010
N/A
International Load Line Certificate
September 13,2003
January 31,2004
RINA
International Oil Pollution Prevention Certificate
September 13,2003
January 31,2004
RINA
ISM - Document Of Compliance
October 6,2014
November 3,2015
IT
ISM - Safety Management Certificate
March 18,2011
November 18,2013
IT
Minimum Safe Manning Document
October 29,2009
October 28,2011
IT
SOLAS Cargo Ship Safety Construction Certificate
September 13,2003
January 31,2004
RINA
SOLAS Cargo Ship Safety Equipment Certificate
May 29,2009
May 28,2011
IT
SOLAS Cargo Ship Safety Radio Certificate
April 10,2006
July 9,2007
IT
Tonnage Certificate, International
December 16,2015
LR