Telluride
Print Q88   
IMO/VIN Callsign Flag Service Year
9256248 V7PN8 MARSHALL ISLANDS Tank Ship 2003
Activity# Port Date Activity - Description Deficiencies
6434643 Christiansted, Virgin Islands Jun 05, 18 Vessel Inspection - Agency Action Complete
6354231 Christiansted, Virgin Islands Feb 21, 18 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoInert Gas SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
1830- The inert gas system shall be designed to the satisfaction of the Administration. The Deck water Seal Float switch is not operating as designed in accordance with the IGS manual chapter 12 Section 1.48.10 D.W.S low water level switch.74 SOLAS(2004 Cons Ed) II-2/5.5.1.1 FSS Code Ch 15.2.1.2 - Action Taken 40ACYes
Resolved DateResolution
Jun 05, 18Vessel provided Class report From Lloyds. Reference the attached report attesting to proper operation of the DWS.
6072749 CORPUS CHRISTI, Texas Jan 24, 17 Vessel Inspection - Approved Inspection
5968536 New Orleans, Louisiana Aug 10, 16 Vessel Inspection - Agency Action Complete
5800412 Houston, Texas Jan 24, 16 Vessel Inspection - Approved Inspection
5097718 TEXAS CITY, Texas Apr 01, 15 Vessel Inspection - Approved Inspection
5093628 TEXAS CITY, Texas Mar 31, 15 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Your vessel was involved in a marine casualty (grounding) at 29* 04.863 N/094* 15.891 W. Satisfactory flag/class survey must take place. 74SOLAS09 I/Reg 11aYes
Resolved DateResolution
Apr 01, 15Received survey report from class resulting from grounding.
5042951 Lewes, Delaware Dec 22, 14 Vessel Inspection - Approved Inspection
4779658 CORPUS CHRISTI, Texas Jan 09, 14 Vessel Inspection - Approved Inspection
4765777 TEXAS CITY, Texas Dec 19, 13 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Operations/ManagementVessel Safety ManagementImproper/Lack of Maintenance
DescriptionDue DateResolved
After any survey of the ship has been completed no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey without the sanction of the administration. The seawater overboard cooling line was found to have temp repairs due to wastage.Yes
Resolved DateResolution
Dec 21, 13Received class report attesting to proper repairs.
SystemSubsystemCause
Operations/ManagementVessel Safety ManagementImproper/Lack of Maintenance
DescriptionDue DateResolved
After any survey of the ship has been completed no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey without the sanction of the administration. Exhaust inlext pipe to scrubber was found to have a temp repair due to wastage.Yes
Resolved DateResolution
Dec 20, 13Permanent repairs made to the satisfaction of class. Conducted satisfactory test of the IGS.
4732591 San Pedro, California Oct 10, 13 Vessel Operational Control - Agency Action Complete
  1
SystemSubsystemCause
NavigationPiloting/Steering
DescriptionDue DateResolved
USCG Port State Control has issued a inbound Letter of deviation to T/V SN FEDERICA for a malfunctioning Gyro Compass on 09 OCT 2013.Oct 10, 13Yes
Resolved DateResolution
Oct 10, 13Class report received, reviewed and accepted. LOD has been cleared.
4684042 San Diego, California Aug 13, 13 Vessel Inspection - Approved Inspection
4517928 New Orleans, Louisiana Jan 22, 13 Vessel Inspection - Approved Inspection
4502989 San Pedro, California Dec 20, 12 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
1840: Suitable means shall be provided for the zero callibration of fixed O2 meter for IG. Crew could not demonstrate zero of sensor. SOLAS 74 (2001 cond ed) ChII-2 Reg 62.18.Yes
Resolved DateResolution
Jan 22, 13Received, reviewed, accepted tech report from QCC-Panama stating the deficiency has been rectified. Report states O2 analyzer has been calibrated as per manufacturer’s instructions.
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
1899: Special consideration shall be made to prevent flue gas leakages into enclosed spaces. Alteration of a drain fitting on both blowers failed allowing free communication of flue gas into IG flat. SOLAS 74 (2001 Cond) Ch II-2 Reg 62.8.1.Dec 20, 12Yes
Resolved DateResolution
Dec 20, 12Fitting removed and drain line capped.
4468921 San Pedro, California Oct 23, 12 Vessel Inspection - Agency Action Complete
4304362 San Francisco, California May 07, 12 Vessel Inspection - Approved Inspection
4303783 San Francisco, California May 07, 12 Vessel Operational Control - Agency Action Complete
4304517 WASHINGTON, District of Columbia May 06, 12 Incident Investigation - Agency Action Complete
4301157 San Pedro, California May 03, 12 Vessel Inspection - Agency Action Complete
4204045 FPO, AP, Guam Dec 11, 11 Vessel Inspection - Approved Inspection
4202304 FPO, AP, Guam Dec 09, 11 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoInert Gas SystemInvalid
DescriptionDue DateResolved
IGS line expansion joint compromised (leaking flue gas) with a tear along starboard side.Dec 11, 11Yes
Resolved DateResolution
May 03, 12IGS line expansion on the port side weather deck has been replaced.
SystemSubsystemCause
NavigationCollision/Grounding AvoidanceInvalid
DescriptionDue DateResolved
Monitor for the X-Band Radar is malfunctioning rendering radar inoperable. Attending technician was unable to repair inoperable monitor will receive new equipment at next U.S. Port.Dec 11, 11Yes
Resolved DateResolution
May 03, 12Deficiency was cleared as per tech report.
4204059 FPO, AP, Guam Dec 08, 11 Vessel Operational Control - Agency Action Complete
3870646 New Orleans, Louisiana Oct 15, 10 Vessel Operational Control - Agency Action Complete
3872559 New Orleans, Louisiana Oct 15, 10 Vessel Inspection - Administrative Action
  1
SystemSubsystemCause
EngineeringDiesel Engine (propulsion-direct drive)
DescriptionDue DateResolved
The vessel experienced a Propulsion Irregularity while in the Mississippi River due to the fuel pump pneumatic control for the #2 cylinder vibrating loose.Oct 15, 10Yes
Resolved DateResolution
Oct 15, 10Received, reviewed and accepted class report from RINA stating the pump pneumatic control was tightened, tested and found satisfactory.
3872037 WASHINGTON, District of Columbia Oct 15, 10 Incident Investigation - Agency Action Complete
3794729 STATEN ISLAND, New York Jul 13, 10 Vessel Operational Control - Agency Action Complete
3782083 New Orleans, Louisiana Jul 01, 10 Vessel Inspection - Administrative Action
  1
SystemSubsystemCause
NavigationPiloting/Steering
DescriptionDue DateResolved
The Gyro Compass was reported not operational.Jul 01, 10Yes
Resolved DateResolution
Jul 01, 10Received, reviewed and accepted technician report from Sperry Marine stating the gyro compass was repaired, tested and found satisfactory.
3716346 Coram, New York Apr 13, 10 Vessel Inspection - Approved Inspection
3678327 STATEN ISLAND, New York Feb 10, 10 Vessel Operational Control - Agency Action Complete
3649321 TEXAS CITY, Texas Dec 17, 09 Vessel Inspection - Approved Inspection
3596695 New Orleans, Louisiana Sep 17, 09 Vessel Inspection - Administrative Action
3474224 New Orleans, Louisiana May 13, 09 Vessel Operational Control - Agency Action Complete
3474379 New Orleans, Louisiana May 13, 09 Vessel Inspection - Administrative Action
  1
SystemSubsystemCause
EngineeringFuel Oil Service System
DescriptionDue DateResolved
Received class report stating that the Fuel pump gear including Fuel Pump Roller Guide and Link for reversing had suffered damage.May 13, 09Yes
Resolved DateResolution
May 17, 09Received class report stating that repairs were made and the Main Engine was tested satisfactorily in both ahead and astern modes.
3427057 STATEN ISLAND, New York Mar 03, 09 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoInert Gas SystemUnknown
DescriptionDue DateResolved
Vessel is to permanently repair burst steam inlet pipe in way of deck seal heating coil, Vessels SMS procedures state heating system must be operating when temperatures are below 0 degrees Celsius, Class to attend vessel on 04 March 2009 and approve repairs.Mar 04, 09Yes
Resolved DateResolution
Mar 05, 09Received report from class attesting to the temporary repair of the steam line, condition of class issued, deficiency cleared.
SystemSubsystemCause
EngineeringFuel Oil Service SystemUnknown
DescriptionDue DateResolved
Vessel's #1 booster pump seal is to be replaced to the satisfaction of class, additionally the surrounding area in the fuel oil purifying room shall be cleaned to satisfaction of class.Apr 04, 09Yes
Resolved DateResolution
May 12, 09Received Class Report from ABS stating that the seal on the Fuel Oil Booster Pump was replaced. Pump was tried out and found satisfactory.
3425220 Jacksonville, Florida Feb 27, 09 Vessel Inspection - Agency Action Complete
3399094 New Orleans, Louisiana Jan 23, 09 Vessel Inspection - Administrative Action
3322739 Wilmington, North Carolina Sep 11, 08 Vessel Inspection - Agency Action Complete
3267681 New Orleans, Louisiana Jul 14, 08 Vessel Inspection - Approved Inspection
3155353 CORPUS CHRISTI, Texas Mar 03, 08 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Fire FightingFiremans Outfit
DescriptionDue DateResolved
Firemans outfit was torn and delaminated, not serviceable. Three remain in good condition. Solas 2004 Cons ed. II-2 Reg. 10.2.3Yes
Resolved DateResolution
Mar 04, 08Receipt of fireman outfit.
3092402 New Orleans, Louisiana Nov 03, 07 Vessel Inspection - Administrative Action
3008728 San Juan, Puerto Rico Jul 27, 07 Vessel Inspection - Approved Inspection
2910848 Christiansted, Virgin Islands Apr 19, 07 Vessel Inspection - Approved Inspection
2873733 Christiansted, Virgin Islands Feb 18, 07 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
LifesavingVisual Distress Signals (General)
DescriptionDue DateResolved
Properly service EPIRB. EPIRB battery has expired.Yes
Resolved DateResolution
Feb 26, 07Received invoice from agent via fax attesting satisfactory replacment of the EPIRB.
2592900 San Francisco, California Feb 27, 06 Boarding - Agency Action Complete
2592514 San Francisco, California Feb 27, 06 Vessel Inspection - Approved Inspection
2553307 Houston, Texas Dec 18, 05 Vessel Operational Control - Agency Action Complete
  1
SystemSubsystemCause
StabilityWatertight Integrity
DescriptionDue DateResolved
17DEC05 Vessel grounded in the Galveston Bay. Operational control was issued requiring the vessel to have an hull survey, locating any damage to the satisfaction of the vessel's Class Society prior to entry into the Port of Houston-Galveston and report findings to local COTP.Yes
Resolved DateResolution
Dec 17, 0517DEC05 received Classification Survey Report confirming vessel''''s structural integrity and sea worthiness. Vessel released by operational control on 17DEC05. 1 def. issued, 1 def cleared.
2552638 Houston, Texas Dec 16, 05 Vessel Inspection - Agency Action Complete
2562010 WASHINGTON, District of Columbia Dec 16, 05 Incident Investigation - Agency Action Complete
2405903 San Pedro, California Jun 27, 05 Boarding - Agency Action Complete
2306853 Houston, Texas Mar 08, 05 Boarding - Approved Inspection
2265047 San Francisco, California Dec 27, 04 Vessel Inspection - Approved Inspection
2127118 San Francisco, California Jul 09, 04 Vessel Inspection - Approved Inspection
2039140 CORPUS CHRISTI, Texas Apr 07, 04 Boarding - Agency Action Complete
2037575 CORPUS CHRISTI, Texas Apr 05, 04 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
IGS blower removed from vessel for repairs. Vessel required to class verify proper repair and installation of IGS blower. SOLAS 74 Ammend CH II-2 reg 62 LEGACY COMPONENT DESC: blowerApr 06, 04Yes
Resolved DateResolution
Apr 08, 04Rcvd class report verifing repairs.
2008508 CORPUS CHRISTI, Texas Feb 18, 04 Vessel Inspection - Agency Action Complete
1981696 STATEN ISLAND, New York Jan 12, 04 Vessel Inspection - Agency Action Complete
1981309 STATEN ISLAND, New York Jan 11, 04 Vessel Inspection - Agency Action Complete
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel January 11,2004 January 11,2005 N/A
Classification Document April 21,2003 January 31,2004 RINA
COC-TVE Annual March 4,2009 March 3,2010 USCG
COC-TVE Renewal March 3,2008 March 3,2010 N/A
International Load Line Certificate September 13,2003 January 31,2004 RINA
International Oil Pollution Prevention Certificate September 13,2003 January 31,2004 RINA
ISM - Document Of Compliance October 6,2014 November 3,2015 IT
ISM - Safety Management Certificate March 18,2011 November 18,2013 IT
Minimum Safe Manning Document October 29,2009 October 28,2011 IT
SOLAS Cargo Ship Safety Construction Certificate September 13,2003 January 31,2004 RINA
SOLAS Cargo Ship Safety Equipment Certificate May 29,2009 May 28,2011 IT
SOLAS Cargo Ship Safety Radio Certificate April 10,2006 July 9,2007 IT
Tonnage Certificate, International December 16,2015 LR