IMO/VIN
Callsign
Flag
Service
Year
9236999
OXBL2
DENMARK
Tank Ship
2003
Activity#
Port
Date
Activity - Description
Deficiencies
5200861
Mobile, Alabama
Jul 30, 15
Vessel Inspection - Approved Inspection
5139536
PHILADELPHIA, Pennsylvania
May 30, 15
Vessel Operational Control - Agency Action Complete
5100294
Mobile, Alabama
Apr 14, 15
Vessel Inspection - Approved Inspection
4839195
New Orleans, Louisiana
Apr 19, 14
Vessel Inspection - Approved Inspection
4809452
Houston, Texas
Mar 08, 14
Vessel Inspection - Approved Inspection
4812097
TEXAS CITY, Texas
Mar 08, 14
Boarding - Agency Action Complete
4811865
TEXAS CITY, Texas
Mar 07, 14
Vessel Inspection - Approved Inspection
3350181
PHILADELPHIA, Pennsylvania
Oct 23, 08
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Engineering Generator (propulsion/auxiliary-electric) Unknown
Description Due Date Resolved 1499- Vessel's batteries for emergency generator have lost charge and cannot supply proper charge to start the emergency generator in the case of a loss of power. Yes
Resolved Date Resolution Oct 28, 08 vessel has new batteries on board, batteries tested and working properly.
3090737
Houston, Texas
Oct 31, 07
Vessel Inspection - Approved Inspection
3090110
Houston, Texas
Oct 30, 07
Vessel Operational Control - Approved Inspection
3086472
Port Arthur, Texas
Oct 24, 07
Vessel Operational Control - Agency Action Complete
3086469
Port Arthur, Texas
Oct 24, 07
Boarding - Agency Action Complete
3085335
Port Arthur, Texas
Oct 24, 07
Vessel Inspection - Approved Inspection
5
0
System Subsystem Cause Pollution Prevention/Response Prevention Equipment
Description Due Date Resolved On 18Oct2007, while cleaning the oil discharge monitoring and control system, a glass tube in the system was broken renedering the system inoperative. Make proper repairs to the satisfaction of the IOPP certificate issuing authority prior to departure. Oct 27, 07 Yes
Resolved Date Resolution Oct 27, 07 Per Vessel Classification Society Report dated 27OCT07: Repair parts have been ordered, conditional MARPOL certificate issued, ODME ops prohibited, retention of all contaminated water oboard via No. 7 Starboard/Slop tank for return voyage to Europe.
System Subsystem Cause Communications Radio Communications
Description Due Date Resolved The battery on the ship's EPIRB has expired. Provide a current battery for the EPIRB to the satifaction of the CSSR certificate issuing authority prior to departure. Oct 27, 07 Yes
Resolved Date Resolution Oct 27, 07 Per Vessel Class Report 27Oct07: Vessels second EPIRB with battery expiration date of 31Oct2007 placed on bridge; Two new EPIRB''''s ordered to be delivered prior to 31OCT07; Both new EPIRBS clearing customs hold as of 27Oct07.
System Subsystem Cause Construction/Loadline Markings
Description Due Date Resolved The port and starboard loadlines are not easily identifyable due to rust. Paint the port and starboard loadlines in contrasting colors to the satisfaction of the ILLC issuing authority prior to 25Nov2007. Nov 25, 07 Yes
Resolved Date Resolution Oct 27, 07 Per Vessel Class Report, 27Oct2007: Port and Starboard loadline marks have been repainted in contrasting color to vessel hull.
System Subsystem Cause Accommodation/Occupational Safety Refrigeration (stores)
Description Due Date Resolved The ship's freezer is inoperative. Make repairs to the satisfaction of the ship's flag state prior to departure. Oct 27, 07 Yes
Resolved Date Resolution Oct 27, 07 Per Vessel Class Report 27Oct2007: Danish Maritime Authority granting single voyage back to Europe until repairs can be made to freezer; (3) 700 Litre chest type freezers provided for this voyage.
System Subsystem Cause Pollution Prevention/Response Prevention Equipment
Description Due Date Resolved While conducting a functional test on the oily water separator, the system could not properly demonstrate the recirculation/shut down function and it displayed an error code. Make proper repairs to the satisfaction of the IOPP issuing authority. Yes
Resolved Date Resolution Oct 26, 07 A relay in the system was identified as the problem and was replaced. The system was tested twice by USCG Marine Inspector with successful results.
2769068
Jacksonville, Florida
Sep 05, 06
Vessel Inspection - Agency Action Complete
2599802
PHILADELPHIA, Pennsylvania
Mar 10, 06
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Inert Gas System Unknown
Description Due Date Resolved Support bracket for the Inert Gas Generator fuel nozzle housing is cracked at the bottom.
Cite: SOLAS 74 A Ch. II-1/26.1 Mar 17, 06 Yes
Resolved Date Resolution Mar 13, 06 Witnessed swatisfactory repairs.
2452156
Staten Island, New York
Aug 05, 05
Boarding - Agency Action Complete
2439298
Houston, Texas
Jul 16, 05
Boarding - Approved Inspection
2373210
Miami Beach, Florida
May 30, 05
Vessel Operational Control - Agency Action Complete
2340514
San Juan, Puerto Rico
Apr 22, 05
Vessel Inspection - Approved Inspection
2250075
CORPUS CHRISTI, Texas
Nov 30, 04
Boarding - Agency Action Complete
2128677
STATEN ISLAND, New York
Jul 11, 04
Vessel Inspection - Approved Inspection
2033305
Christiansted, Virgin Islands
Mar 28, 04
Boarding - Agency Action Complete
2027327
STATEN ISLAND, New York
Mar 19, 04
Vessel Inspection - Administrative Action
2025234
STATEN ISLAND, New York
Mar 16, 04
Vessel Inspection - Agency Action Complete
2024453
STATEN ISLAND, New York
Mar 15, 04
Vessel Inspection - Agency Action Complete
2
0
System Subsystem Cause Navigation Collision/Grounding Avoidance Placed in Improper Service
Description Due Date Resolved ARPA labels missing, provide receipt for same prior to departing the port of NY. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA) Mar 15, 04 Yes
Resolved Date Resolution Mar 19, 04 LABELS NOW AFFIXED TO THE SATISFACTION OF CLASS.
System Subsystem Cause Pollution Prevention/Response Prevention Equipment Improper Installation
Description Due Date Resolved ODME is not functional and must be repaired prior to departing the port of NY. LEGACY COMPONENT DESC: Cargo Monitor/Control System Mar 15, 04 Yes
Resolved Date Resolution Mar 19, 04 ODME WAS TESTED AND FOUND SATISFACTORY BY CLASS.
Documents
Issued
Expires
Agency
Certificate of Compliance - Tank Vessel
March 15,2004
March 15,2006
USCG
Classification Document
May 25,2013
May 29,2018
LR
COC-TVE Annual
October 28,2008
October 25,2009
N/A
COC-TVE Renewal
October 25,2007
October 25,2009
N/A
International Load Line Certificate
May 19,2015
May 29,2018
LR
International Oil Pollution Prevention Certificate
August 6,2014
May 29,2018
LR
ISM - Document Of Compliance
November 7,2003
November 3,2008
LR
ISM - Safety Management Certificate
September 1,2012
September 6,2016
LR
Minimum Safe Manning Document
May 27,2003
DK
NLS Certificate
May 30,2003
May 29,2008
LR
SOLAS Cargo Ship Safety Construction Certificate
May 25,2013
May 29,2018
LR
SOLAS Cargo Ship Safety Equipment Certificate
September 7,2013
May 29,2018
LR
SOLAS Cargo Ship Safety Radio Certificate
May 25,2013
May 29,2018
LR
Tonnage Certificate, International
April 30,2003
LR