Marlin Shikoku
Print Q88   
IMO/VIN Callsign Flag Service Year
9841627 9V5874 SINGAPORE Tank Ship 2019
Activity# Port Date Activity - Description Deficiencies
7299277 San Pedro, California Aug 29, 21 Vessel Inspection - Agency Action Complete
6915407 New Orleans, Louisiana Mar 01, 20 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemPlaced in Improper Service
DescriptionDue DateResolved
06199-Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between bolt holes, and in line with the bolt holes pattern. PSCO observed 04 vapor line header pins did not have permanent studs. Rectify before loading cargoes that require vapor control. 46 CFR 39.2001(i)Yes
Resolved DateResolution
Mar 12, 20Pin was welded as per CFR, ABS provided class report and pictures
Documents Issued Expires Agency
COC-TVE Renewal March 1,2020 March 1,2022 NEWMS
International Load Line Certificate September 2,2019 March 21,2024 ABS
ISM - Safety Management Certificate August 13,2019 August 12,2024 ABS
SOLAS Cargo Ship Safety Construction Certificate September 2,2019 March 21,2024 ABS
SOLAS Cargo Ship Safety Equipment Certificate September 2,2019 March 21,2024 ABS