9416408 D5DN7 LIBERIA Tank Ship 2014
Activity# Port Date Activity - Description Deficiencies
6382681 STATEN ISLAND, New York Apr 01, 18 Vessel Inspection - Approved Inspection
5787340 TEXAS CITY, Texas Dec 29, 15 Vessel Inspection - Approved Inspection
5750688 New Orleans, Louisiana Oct 26, 15 Vessel Inspection - Agency Action Complete
5073164 Houston, Texas Feb 23, 15 Vessel Inspection - Approved Inspection
5062179 Houston, Texas Feb 01, 15 Vessel Inspection - Approved Inspection
5037215 Savannah, Georgia Dec 10, 14 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringDiesel Engine (propulsion-reduction gear)
DescriptionDue DateResolved
The main starting air arrangements for main propulsion internal combustion engine shall be adequately protected against the effects of backfiring. The main engine burst disk(relief valve) of the starting air valve of cylinder #3 burst (relieved) resulting in reduced in main propulsion capabilities. Class to attest to root cause and repairs to main propulsion engine.74/78 SOLAS 09 CON./CH II-1/34.2Yes
Resolved DateResolution
Feb 23, 15Received class report attesting to rectified deficiency, class report attached to documents of act 5073164.
5041721 WASHINGTON, District of Columbia Dec 10, 14 Incident Investigation - Agency Action Complete
5034293 Jacksonville, Florida Dec 08, 14 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoHolds/TanksImproper/Lack of Maintenance
DescriptionDue DateResolved
Radar ullage device system at cargo tank(stb1) indicates 99%of capacity, manual gauging indicates 98%. Class shall attest to proper operation of ullage system. 74SOLAS(09)CHII-2/4.5.5.3.3Yes
Resolved DateResolution
Feb 01, 15Received, reviewed and accepted class report from DNV/GL attesting to the proper operation of the ullage radar system. System has been serviced and recalibrated by technicians, and software has been amended to correct values. All tested and found sat.
SystemSubsystemCause
Deck/CargoCargo HeatingImproper/Lack of Maintenance
DescriptionDue DateResolved
Vessel high level and overflow alarm did not operate correctly at time of testing. 74Solas(09)CHVII/Reg10.1 IBC Chapter 15.19 46CFR 39.20-7Dec 08, 14Yes
Resolved DateResolution
Dec 08, 14Alarms were restored to proper working order.
Documents Issued Expires Agency
Certificate of Fitness - Chemical Carrier August 26,2014 July 7,2019 DNV
Classification Document November 17,2017 September 7,2019 Class
International Certificate of Fitness - Chemical December 1,2017 September 7,2019 Class
International Load Line Certificate November 17,2017 September 7,2019 Class
International Oil Pollution Prevention Certificate November 17,2017 September 7,2019 Class
ISM - Document Of Compliance April 6,2017 May 22,2022 LR
ISM - Safety Management Certificate July 15,2014 January 6,2015 N/A
Minimum Safe Manning Document July 6,2014 LR
SOLAS Cargo Ship Safety Construction Certificate November 17,2017 September 7,2019 Class
SOLAS Cargo Ship Safety Equipment Certificate November 17,2017 September 7,2019 Class
SOLAS Cargo Ship Safety Radio Certificate November 17,2017 September 7,2019 Class
Tonnage Certificate, International April 9,2014 DNV