IMO/VIN
Callsign
Flag
Service
Year
9416408
D5DN7
LIBERIA
Tank Ship
2014
Activity#
Port
Date
Activity - Description
Deficiencies
6382681
STATEN ISLAND, New York
Apr 01, 18
Vessel Inspection - Approved Inspection
5787340
TEXAS CITY, Texas
Dec 29, 15
Vessel Inspection - Approved Inspection
5750688
New Orleans, Louisiana
Oct 26, 15
Vessel Inspection - Agency Action Complete
5073164
Houston, Texas
Feb 23, 15
Vessel Inspection - Approved Inspection
5062179
Houston, Texas
Feb 01, 15
Vessel Inspection - Approved Inspection
5037215
Savannah, Georgia
Dec 10, 14
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause Engineering Diesel Engine (propulsion-reduction gear)
Description Due Date Resolved The main starting air arrangements for main propulsion internal combustion engine shall be adequately protected against the effects of backfiring. The main engine burst disk(relief valve) of the starting air valve of cylinder #3 burst (relieved) resulting in reduced in main propulsion capabilities. Class to attest to root cause and repairs to main propulsion engine.74/78 SOLAS 09 CON./CH II-1/34.2 Yes
Resolved Date Resolution Feb 23, 15 Received class report attesting to rectified deficiency, class report attached to documents of act 5073164.
5041721
WASHINGTON, District of Columbia
Dec 10, 14
Incident Investigation - Agency Action Complete
5034293
Jacksonville, Florida
Dec 08, 14
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Deck/Cargo Holds/Tanks Improper/Lack of Maintenance
Description Due Date Resolved Radar ullage device system at cargo tank(stb1) indicates 99%of capacity, manual gauging indicates 98%. Class shall attest to proper operation of ullage system. 74SOLAS(09)CHII-2/4.5.5.3.3 Yes
Resolved Date Resolution Feb 01, 15 Received, reviewed and accepted class report from DNV/GL attesting to the proper operation of the ullage radar system. System has been serviced and recalibrated by technicians, and software has been amended to correct values. All tested and found sat.
System Subsystem Cause Deck/Cargo Cargo Heating Improper/Lack of Maintenance
Description Due Date Resolved Vessel high level and overflow alarm did not operate correctly at time of testing.
74Solas(09)CHVII/Reg10.1
IBC Chapter 15.19
46CFR 39.20-7 Dec 08, 14 Yes
Resolved Date Resolution Dec 08, 14 Alarms were restored to proper working order.
Documents
Issued
Expires
Agency
Certificate of Fitness - Chemical Carrier
August 26,2014
July 7,2019
DNV
Classification Document
November 17,2017
September 7,2019
Class
International Certificate of Fitness - Chemical
December 1,2017
September 7,2019
Class
International Load Line Certificate
November 17,2017
September 7,2019
Class
International Oil Pollution Prevention Certificate
November 17,2017
September 7,2019
Class
ISM - Document Of Compliance
April 6,2017
May 22,2022
LR
ISM - Safety Management Certificate
July 15,2014
January 6,2015
N/A
Minimum Safe Manning Document
July 6,2014
LR
SOLAS Cargo Ship Safety Construction Certificate
November 17,2017
September 7,2019
Class
SOLAS Cargo Ship Safety Equipment Certificate
November 17,2017
September 7,2019
Class
SOLAS Cargo Ship Safety Radio Certificate
November 17,2017
September 7,2019
Class
Tonnage Certificate, International
April 9,2014
DNV