Ag Mars
Print Q88   
IMO/VIN Callsign Flag Service Year
9337315 V7JZ9 LIBERIA Tank Ship 2006
Activity# Port Date Activity - Description Deficiencies
6876592 NEW HAVEN, Connecticut Dec 25, 19 Vessel Inspection - Approved Inspection
6593578 Mobile, Alabama Dec 07, 18 Vessel Inspection - Approved Inspection
6539968 New Orleans, Louisiana Sep 14, 18 Vessel Inspection - Agency Action Complete
6527096 PHILADELPHIA, Pennsylvania Aug 30, 18 Vessel Inspection - Agency Action Complete
5851845 San Juan, Puerto Rico Apr 14, 16 Vessel Inspection - Approved Inspection
5815745 Houston, Texas Feb 16, 16 Vessel Inspection - Approved Inspection
5804453 Mobile, Alabama Jan 27, 16 Vessel Inspection - Approved Inspection
5772834 San Juan, Puerto Rico Dec 08, 15 Vessel Inspection - Approved Inspection
4889949 San Juan, Puerto Rico Jun 13, 14 Vessel Inspection - Approved Inspection
4907041 WASHINGTON, District of Columbia Jun 13, 14 Incident Investigation - Agency Action Complete
4877989 San Juan, Puerto Rico Jun 06, 14 Vessel Inspection - Agency Action Complete
4770019 New Orleans, Louisiana Dec 16, 13 Vessel Inspection - Approved Inspection
4593781 STATEN ISLAND, New York May 10, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Operations/ManagementBallast Water Managment
DescriptionDue DateResolved
Any vsl w/ BW tanks bound to US must report the required info to NBIC at least 24 hrs before arrival at the port or place of destination if the vsl's voyage exceeds 24 hrs. Vsl did not submit required info to NMIC on voyage to Port of NY.May 10, 13Yes
Resolved DateResolution
May 10, 13Vsl was given guidance on submittal of report to NBIC and deficiency was rectified on the spot.
4330753 New Orleans, Louisiana Jun 01, 12 Vessel Inspection - Approved Inspection
4327073 New Orleans, Louisiana Jun 01, 12 Boarding - Agency Action Complete
4329855 New Orleans, Louisiana May 31, 12 Vessel Inspection - Administrative Action
4212204 Wilmington, North Carolina Dec 21, 11 Vessel Inspection - Agency Action Complete
4066299 San Juan, Puerto Rico Jul 03, 11 Vessel Operational Control - Approved Inspection
  1
SystemSubsystemCause
EngineeringCompressed Air System (start air)Design Flaw
DescriptionDue DateResolved
MDE shut-off several times during outbound transit. Pilots reported the incident to command center.Jul 03, 11Yes
Resolved DateResolution
Jul 03, 11MDEstarting air distributor and related control air system solenoid valves (2) were replaced with spares. Classification Society verified and approved repairs.
4069684 Ponce, Puerto Rico Jun 30, 11 Vessel Inspection - Approved Inspection
4055992 Ponce, Puerto Rico Jun 25, 11 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
CommunicationsRadio Communications
DescriptionDue DateResolved
EPIRB battery expired. Replace battery prior to departure. Provide Masters statement attesting to the replacement of battery.Jun 28, 11Yes
Resolved DateResolution
Jun 30, 11Received signed statement from Master attesting to proper installation of EPIRB battery.
3718193 STATEN ISLAND, New York Apr 16, 10 Vessel Inspection - Approved Inspection
3576202 TEXAS CITY, Texas Aug 26, 09 Vessel Inspection - Approved Inspection
3420824 STATEN ISLAND, New York Feb 20, 09 Vessel Inspection - Approved Inspection
3157959 STATEN ISLAND, New York Mar 04, 08 Vessel Inspection - Approved Inspection
3140733 San Francisco, California Feb 02, 08 Vessel Operational Control - Agency Action Complete
2981741 CORPUS CHRISTI, Texas Jul 03, 07 Vessel Inspection - Administrative Action
2947837 BOSTON, Massachusetts Jun 02, 07 Boarding - Agency Action Complete
2912781 New Orleans, Louisiana Apr 22, 07 Vessel Inspection - Administrative Action
2869882 New Orleans, Louisiana Feb 09, 07 Vessel Inspection - Administrative Action
2868022 New Orleans, Louisiana Feb 07, 07 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoInert Gas SystemUnknown
DescriptionDue DateResolved
PIPING DIAGRAM GDZ-1709 CORRESPONDS TO THE INSTALLED IGS SYSTEM'S NON-RETURN VALVE ON THE CARGO SIDE OF THE DECK WATER SEAL. HOWEVER, THE DIAGRAM DOES NOT PROPERLY CORRESPOND TO THE INSTALLED POSITIVE STOPPING DEVICE.Mar 07, 07Yes
Resolved DateResolution
Feb 09, 07Received proper documentation from Det Norske Veritas satisfying requirement.
2862993 New Orleans, Louisiana Feb 06, 07 Boarding - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel May 10,2013 May 10,2015 SECNY
Certificate of Fitness - Chemical Carrier March 30,2018 November 3,2018 ABS
Classification Document March 30,2018 November 3,2021 ABS
International Certificate of Fitness - Chemical June 5,2013 November 3,2016 ABS
International Load Line Certificate March 30,2018 November 3,2021 ABS
International Oil Pollution Prevention Certificate March 30,2018 November 3,2021 ABS
ISM - Document Of Compliance October 15,2008 October 13,2013 DNV
ISM - Safety Management Certificate March 30,2018 September 29,2018 ABS
Minimum Safe Manning Document March 29,2018 LR
SOLAS Cargo Ship Safety Construction Certificate March 30,2018 November 3,2021 ABS
SOLAS Cargo Ship Safety Equipment Certificate March 30,2018 November 3,2021 ABS
SOLAS Cargo Ship Safety Radio Certificate March 30,2018 November 3,2021 ABS
Tonnage Certificate, International June 1,2018 LR