Double Skin 302
Print Q88   
IMO/VIN Callsign Flag Service Year
1201304 WDJ2229 UNITED STATES Public Tankship/Barge 2007
Activity# Port Date Activity - Description Deficiencies
7011305 STATEN ISLAND, New York Jul 20, 20 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
(a) The owner, master, or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. The pressure gauge of the Fire Extinguisher on deck read zero pressure. Recommend creating a monthly maintenance schedule to inspect the condition of on board extinguishers.Aug 03, 20Yes
Resolved DateResolution
Jul 28, 20Received evidence that the unsatisfactory extingusher has been replaced with RFI unit.
6810517 STATEN ISLAND, New York Sep 13, 19 Vessel Inspection - Approved Inspection
6570882 STATEN ISLAND, New York Oct 30, 18 Vessel Inspection - Approved Inspection
6549339 WASHINGTON, District of Columbia Sep 26, 18 Incident Investigation - Agency Action Complete
6495768 STATEN ISLAND, New York Jul 30, 18 Vessel Inspection - Approved Inspection
6240063 STATEN ISLAND, New York Aug 14, 17 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Washed out welds identified during dry dock exam, documented on worklist. To be cleared by credit dry dock exam.Aug 31, 17Yes
Resolved DateResolution
Aug 31, 17Welds have been repaired.
6026011 WASHINGTON, District of Columbia Oct 20, 16 Incident Investigation - Agency Action Complete
5982290 STATEN ISLAND, New York Aug 25, 16 Vessel Inspection - Approved Inspection
5193049 STATEN ISLAND, New York Jul 23, 15 Vessel Inspection - Approved Inspection
4966670 STATEN ISLAND, New York Aug 27, 14 Vessel Inspection - Approved Inspection
4742333 WASHINGTON, District of Columbia Oct 16, 13 Incident Investigation - Agency Action Complete
4711160 STATEN ISLAND, New York Sep 10, 13 Vessel Inspection - Agency Action Complete
  3
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
Demonstrate high level/overfill alarm system alarms in the event of a loss of power. 46 CFR 39.20-7 (b) (2)Oct 03, 13Yes
Resolved DateResolution
Oct 01, 13Vessel demonstrated loss of power alarm (audible/visual). On/off switch inside APM-2 alarm panel is used to simulate loss of power and demonstrate operation of this safety feature.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Demonstrate proper operation of the ground detection system for the 120v panel in the machinery space. 46 CFR 111.05-21(c)Oct 03, 13Yes
Resolved DateResolution
Oct 01, 13Vessel had a ground in the stern void, electrician corrected the problem and inspectors witnessed 120v panel with no ground fault indication with all breakers on.
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
Vessel must demonstrate proper testing of intrinsically safe overfill control system. 46 CFR 39.20-9(b)(3)Oct 03, 13Yes
Resolved DateResolution
Oct 01, 13Using a multi-meter, tested continuity in the high level and overfill circuits. Using the #3 P/S cargo tank sensors, witnessed proper break in continuity indicating successful signal delivery to the overfill control system connection.
4465200 STATEN ISLAND, New York Oct 16, 12 Vessel Inspection - Administrative Action
4403504 STATEN ISLAND, New York Aug 06, 12 Vessel Inspection - Agency Action Complete
  13
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
# 1 Portside void, bay 2 from Aft, 2nd long from top V/W as marked.Nov 06, 12Yes
Resolved DateResolution
Oct 25, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
# 1 STBD void 4 cracked welds. #3 bay from fwd side longs # 2, 3, 6 , from bottom. V/W # 4 bay from Fwd. #6 side long from bottom V/W as marked.Nov 06, 12Yes
Resolved DateResolution
Oct 25, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
# 2 portside void bay 2 from Aft, 3rd long from bottom , V/W as marked.Nov 06, 12Yes
Resolved DateResolution
Oct 25, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
# 3 portside void Bay 4 from Aft, 6rd long from top, V/W as marked.Oct 25, 12Yes
Resolved DateResolution
Oct 25, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
# 3 portside void Bay 4, and Bay 6, from Aft, 6rd long from top, V/W as marked.Nov 06, 12Yes
Resolved DateResolution
Oct 25, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
# 4 STBD void, 3 frames from aft bulkhead, on fwd side, middle bottom long V/W.Nov 06, 12Yes
Resolved DateResolution
Oct 30, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
# 7 port side void bay 2 from forward, 3rd long from bottom R/WNov 06, 12Yes
Resolved DateResolution
Oct 25, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
#2 portside void Bay 3 and Bay 4 from Aft, 3rd long from bottom , V/W as marked.Nov 06, 12Yes
Resolved DateResolution
Oct 25, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
#3 STBD void had 3 cracked welds. Located 1st bay from forward along the side long as marked and 2nd bay from side longs, V/W.Nov 06, 12Yes
Resolved DateResolution
Oct 25, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
#6 STBD void 2 side shell stiffeners from aft bulkhead, 3 longs from bottom V/W broken weld as markedOct 25, 12Yes
Resolved DateResolution
Oct 25, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
2 STBD void, 3 frames from aft bulkhead, re attach weld on 3 longs from bottom, as marked.Nov 06, 12Yes
Resolved DateResolution
Oct 25, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
2 STBD void, 4 frames from aft bulkhead, re-attached welds on 1 and 2 longs from bottom and middle bottom longs.Nov 06, 12Yes
Resolved DateResolution
Oct 25, 12
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Have all void space hatch covers removed and ready for USCG inspection.Nov 06, 12Yes
Resolved DateResolution
Oct 25, 12
4398165 PHILADELPHIA, Pennsylvania Aug 01, 12 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Cargo hose not labeled with "Oil Service"Sep 02, 12Yes
Resolved DateResolution
Aug 06, 12Corrected on the spot by stenciling cargo hose.
SystemSubsystemCause
LifesavingLifebuoys
DescriptionDue DateResolved
During annual USCG audit, both life rings were found poorly stenciled, and the forward life ring's plug was deteriorated.Aug 06, 12Yes
Resolved DateResolution
Aug 06, 12
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
Flame screen missing hold down screwMar 10, 12Yes
Resolved DateResolution
Feb 09, 12Corrected on site, added screen to flame screen.
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
Vapor hose missing red color stenciling.Feb 16, 12Yes
Resolved DateResolution
Feb 20, 12Colored vapor hose appropriately.
4263325 PHILADELPHIA, Pennsylvania Mar 14, 12 Vessel Inspection - Approved Inspection
4111593 PHILADELPHIA, Pennsylvania Aug 10, 11 Vessel Inspection - Administrative Action
3833914 PHILADELPHIA, Pennsylvania Aug 26, 10 Vessel Inspection - Approved Inspection
3624788 PHILADELPHIA, Pennsylvania Oct 28, 09 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Provide verification that the cargo pump engine wiring harness is compliant with the Class 1 Division 1 requirements as described in 46 CFR 111.105-31.Sep 30, 15Yes
Resolved DateResolution
Sep 10, 13Vessel replaced cargo pump engines were replaced on the weather deck to meet the Class 1 Division 1 requirements as described in 46 CFR 111.105.31.
3561553 PHILADELPHIA, Pennsylvania Aug 11, 09 Vessel Inspection - Approved Inspection
3320816 PHILADELPHIA, Pennsylvania Sep 09, 08 Vessel Inspection - Approved Inspection
3129997 PHILADELPHIA, Pennsylvania Jan 14, 08 Vessel Inspection - Approved Inspection
3130115 WASHINGTON, District of Columbia Jan 12, 08 Incident Investigation - Agency Action Complete
3176082 PHILADELPHIA, Pennsylvania Dec 06, 07 Vessel Inspection - Approved Inspection
3016345 NASHVILLE, Tennessee Aug 08, 07 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)Design Flaw
DescriptionDue DateResolved
provide proof of cargo pump engine wiring harness meeting 46 cfr 111.50 NEC Class1/Div 1 per D8 (m) policy letter dated 02-2005 NLT 01 Aug 08. Historically archived due to inactivity.Oct 31, 08Yes
Resolved DateResolution
Aug 17, 17Reissued under activity 3624788.
Documents Issued Expires Agency
Cargo Authority Attachment October 7,2013 N/A
CERTIFICATE OF DOCUMENTATION July 29,2020 August 31,2021 USCG
Certificate of Inspection September 8,2017 September 8,2022 USCG
Certificate of Inspection - Amended September 8,2017 September 8,2022 USCG