DBL 78
Print Q88   
IMO/VIN Callsign Flag Service Year
1102126 WDB6235 UNITED STATES Tank Barge 2000
Activity# Port Date Activity - Description Deficiencies
7220598 Seattle, Washington Jun 10, 21 Vessel Inspection - Approved Inspection
7011533 Seattle, Washington Jul 24, 20 Vessel Inspection - Approved Inspection
6977191 PORTLAND, Oregon Jun 15, 20 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
All electrical installations in hazardous locations must comply with the general requirements of section 33 of IEEE 45-1998 (incorporated by reference; see 46 CFR 110.10-1), and with either Articles 500 through 505 of NFPA NEC 2002 (incorporated by reference; see 46 CFR 110.10-1) or with the IEC 60079 series (as defined in 46 CFR 111.105-1 and incorporated by reference; see 46 CFR 110.10-1). A cable penetration from the weatherdeck to the void underneath the administration office was not vapor tight. Deficiency is to be rectified prior to the carriage of cargo.Aug 09, 20Yes
Resolved DateResolution
Jul 24, 20Rocks block installed around cable.
6962576 Seattle, Washington May 28, 20 Vessel Inspection - Agency Action Complete
6792831 VALDEZ, Alaska Aug 22, 19 Facility Transfer Monitor - Agency Action Complete
6792520 VALDEZ, Alaska Aug 22, 19 Vessel Inspection - Approved Inspection
6751102 VALDEZ, Alaska Jul 15, 19 Vessel Inspection - Approved Inspection
6564696 Seattle, Washington Oct 20, 18 Vessel Inspection - Agency Action Complete
6390550 JBER, Alaska Apr 10, 18 Vessel Inspection - Approved Inspection
6368668 VALDEZ, Alaska Mar 09, 18 Vessel Inspection - Approved Inspection
6369184 JBER, Alaska Mar 09, 18 Vessel Inspection - Approved Inspection
6221580 VALDEZ, Alaska Jul 26, 17 Facility Transfer Monitor - Agency Action Complete
6190765 VALDEZ, Alaska Jul 14, 17 Vessel Inspection - Agency Action Complete
6101342 WASHINGTON, District of Columbia Mar 08, 17 Incident Investigation - Agency Action Complete
6022776 JBER, Alaska Oct 15, 16 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
Gouge out and drill stop crack on the weld seam IWO port side frame #1 - #2.Oct 14, 16Yes
Resolved DateResolution
Oct 20, 16proper repairs have been made to the damage on port side hull. Repairs also were observed by ABS surveyor Menryk Sienkiewiez.
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
Make proper repairs to port side shell and side long IWO frame #1 - #2.Nov 21, 16Yes
Resolved DateResolution
Oct 20, 16proper repairs have been made to the damage on port side hull. Repairs also were observed by ABS surveyor Menryk Sienkiewiez.
5963525 VALDEZ, Alaska Aug 05, 16 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringCompressed Air System (start air)
DescriptionDue DateResolved
Prove proper operation of start air relief valves. 46 CFR 54.15-10(g)Sep 05, 16Yes
Resolved DateResolution
Aug 25, 16
5907256 WASHINGTON, District of Columbia May 05, 16 Incident Investigation - Agency Action Complete
5797858 VALDEZ, Alaska Jan 14, 16 Facility Transfer Monitor - Agency Action Complete
5795558 WASHINGTON, District of Columbia Nov 13, 15 Incident Investigation - Agency Action Complete
5131573 Seattle, Washington May 20, 15 Vessel Inspection - Approved Inspection
  6
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Blanks must be provided for the openings located in the navigation light panelboard IAW 46 CFR 111.40-1Jul 07, 15Yes
Resolved DateResolution
Jul 07, 15Blanks installed
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Cargo hoses shall be stenciled with the most recent hydro test conducted on 19MAY2015 IAW 33 CFR 154.500(f).Jul 14, 15Yes
Resolved DateResolution
Jul 07, 15Hoses stenciled.
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
Navigation lights need to be replaced: stern light, (2) mast head lights not working properly. IAW COLREGS, no transitting after sunset.Jul 07, 15Yes
Resolved DateResolution
Jul 07, 15Navigation lights replaced.
SystemSubsystemCause
EngineeringDiesel Engine (propulsion-direct drive)
DescriptionDue DateResolved
Program software not available during time of inspection for shutdown/alarm testing of Detoit Diesel series 60 engines (#1 and #2). Service report must be provided, attesting to the satisfactory testing of both engines, or satisfactorily tested in the presence of a USCG marine inspector IAW 46 CFR 58.05-1.Jul 14, 15Yes
Resolved DateResolution
Jul 07, 15Third party report provided for inspection and testing.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Remote emergency shutdowns for cargo pump prime movers not operational. Solenoid valves need to be replaced. Upon repair, emergency shutdowns shall be tested in the presence of a USCG marine inspector IAW 46 CFR 32.50-35.Yes
Resolved DateResolution
Jul 07, 15Solenoids for intake air dampers replaced, operational test completed.
SystemSubsystemCause
Fire FightingMiscellaneous Items
DescriptionDue DateResolved
Vapor tightness for both machinery spaces compromised due to holes located on the rubber boots leading from the #1 and #2 cargo pumps to the machinery spaces housing for pump prime movers. Rubber boots need to be replaced and verified by the attending marine inspector IAW 46 CFR 111.105Yes
Resolved DateResolution
Jul 07, 15New boots installed.
5107125 Seattle, Washington Apr 09, 15 Vessel Inspection - Agency Action Complete
4973861 JBER, Alaska Oct 29, 14 Vessel Inspection - Approved Inspection
4982094 VALDEZ, Alaska Sep 12, 14 Vessel Inspection - Approved Inspection
4974440 VALDEZ, Alaska Sep 04, 14 Vessel Inspection - Approved Inspection
4948329 VALDEZ, Alaska Aug 08, 14 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)
DescriptionDue DateResolved
Secure exhaust leak on stb cargo pump.Sep 12, 14Yes
Resolved DateResolution
Sep 12, 14Installed new band clamps between turbo and exhaust piping.
SystemSubsystemCause
EngineeringCompressed Air System (control)
DescriptionDue DateResolved
Test #1 and #2 house air relief valves.Sep 12, 14Yes
Resolved DateResolution
Sep 12, 14Tested 2 relief valves. Vavles released at required PSI.
4811504 JBER, Alaska Mar 03, 14 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Submit proposal for permanent & proper repairs of forepeak lower void damage identified stbd of centerline (sideshell, deck & bottom longs, brackets, & transverse frame) & in way of #2 port transverse frame & sideshell aft of frame. Repairs to be completed prior to carrying cargo. Barge authorized transit to Seward, Alaska.Yes
Resolved DateResolution
Mar 15, 14Cleared CG-835 items. Port rake insert was cleared by ABS on 14MAR14 and Fwd rake insert was cleared 15MAR14 by CWO Nieves. Vaccum box was used to test all final welds on the fwd rake. All sat.
4808114 WASHINGTON, District of Columbia Feb 16, 14 Incident Investigation - Agency Action Complete
4772459 DUTCH HARBOR, Alaska Dec 20, 13 Vessel Transfer Monitor - Approved Inspection
4647458 Seattle, Washington Jul 08, 13 Enforcement - Agency Action Complete
4647372 WASHINGTON, District of Columbia Jun 28, 13 Incident Investigation - Agency Action Complete
4505164 ST PETERSBURG, Florida Dec 20, 12 Vessel Inspection - Approved Inspection
4505164 Tampa, Florida Dec 20, 12 Vessel Inspection - Approved Inspection
4461047 New Orleans, Louisiana Oct 10, 12 Vessel Inspection - Approved Inspection
4454356 ST PETERSBURG, Florida Oct 01, 12 Vessel Inspection - Approved Inspection
4454356 Tampa, Florida Oct 01, 12 Vessel Inspection - Approved Inspection
4377905 New Orleans, Louisiana Aug 09, 12 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Provide current COFR - 33 CFR 138 - Prior to entering EEZ of U.S.Yes
Resolved DateResolution
Oct 10, 12Electronically verified valid COFR received 03Oct12.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Provide required testing of piping & hoses onboard. 33 CFR 156.170 - Prior to transferring cargo in U.S.Yes
Resolved DateResolution
May 14, 13
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
Provide required testing of portable IM Tanks - 46 CFR 98 - Prior to usingYes
Resolved DateResolution
Mar 01, 13Witnessed pressure test/ internal/ external exam of the 3 IM tanks. See document secgtion for certificartion report from PE
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
Repair high level alarm on #3 starboard cargo tank. 46 CFR 39.20 - Prior to loading cargo in U.S.Yes
Resolved DateResolution
May 14, 13
4101611 New Orleans, Louisiana Aug 01, 11 Vessel Inspection - Approved Inspection
3781202 STATEN ISLAND, New York Jun 25, 10 Vessel Inspection - Agency Action Complete
3726342 NEW HAVEN, Connecticut Apr 28, 10 Vessel Transfer Monitor - Agency Action Complete
3689306 PHILADELPHIA, Pennsylvania Mar 04, 10 Vessel Inspection - Approved Inspection
3685300 NEW HAVEN, Connecticut Feb 24, 10 Enforcement - Payment Received
3672609 STATEN ISLAND, New York Jan 30, 10 Vessel Inspection - Agency Action Complete
3674276 WASHINGTON, District of Columbia Dec 24, 09 Incident Investigation - Agency Action Complete
3638572 STATEN ISLAND, New York Dec 03, 09 Vessel Inspection - Agency Action Complete
3617482 STATEN ISLAND, New York Oct 19, 09 Vessel Inspection - Agency Action Complete
3611979 New Castle, New Hampshire Oct 09, 09 Vessel Transfer Monitor - Approved Inspection
3551761 STATEN ISLAND, New York Jul 31, 09 Vessel Inspection - Agency Action Complete
3496161 STATEN ISLAND, New York Jun 05, 09 Vessel Inspection - Agency Action Complete
3363023 WASHINGTON, District of Columbia Oct 24, 08 Incident Investigation - Agency Action Complete
3247821 STATEN ISLAND, New York Jun 25, 08 Vessel Inspection - Agency Action Complete
3153061 STATEN ISLAND, New York Feb 25, 08 Vessel Inspection - Agency Action Complete
  7
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
1 Port wing tank, bay 4, V/W swash bulkhead IWO SSL 1 as marked.Mar 31, 08Yes
Resolved DateResolution
Mar 15, 08
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
3 Port wing tank, bay 5, C/R frame 5 as marked.Mar 31, 08Yes
Resolved DateResolution
Mar 15, 08
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
3 Port wing tank, bay 6, C/R frame 6 as marked.Mar 31, 08Yes
Resolved DateResolution
Mar 15, 08
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
C/R sideshell IWO 3 port back to good metal.Mar 31, 08Yes
Resolved DateResolution
Mar 15, 08
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Install tachometer for generator.Apr 03, 08Yes
Resolved DateResolution
Apr 03, 08
SystemSubsystemCause
Construction/LoadlineMarkings
DescriptionDue DateResolved
Re-mark load line IAW int'l load line certificate.Apr 03, 08Yes
Resolved DateResolution
Apr 03, 08
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Vessel is restricted to the carriage of grade A (max. 25 psia Reid) and Lower Grade Flammable or Combustible Liquids Identified in 46 CFR Table 30.25-1 as Pollution Category I and cargoes listed in the IBC Code identified as “Other Substances (OS)” until the Cargo Authority Attachment has been verified by the Marine Safety Center for suitability to carry cargoes regulated under MARPOL Annex II.Yes
Resolved DateResolution
Jun 25, 08the cargo authority was amended to allow cargoes authorized prior to Jan 07 to be continued to be carried on domestic routes while restricting cargoes to pollution cat 1 and OS''s on international routes.
3147948 NEW HAVEN, Connecticut Feb 15, 08 Facility Transfer Monitor - Agency Action Complete
3141713 WASHINGTON, District of Columbia Feb 03, 08 Incident Investigation - Agency Action Complete
3001510 STATEN ISLAND, New York Jul 20, 07 Vessel Transfer Monitor - Approved Inspection
2980685 STATEN ISLAND, New York Jul 02, 07 Vessel Inspection - Agency Action Complete
2922075 STATEN ISLAND, New York May 04, 07 Vessel Inspection - Approved Inspection
2854772 Belfast, Maine Jan 12, 07 Enforcement - Payment Received
2854655 Belfast, Maine Jan 12, 07 Vessel Transfer Monitor - Agency Action Complete
2854753 WASHINGTON, District of Columbia Jan 11, 07 Incident Investigation - Agency Action Complete
2720017 STATEN ISLAND, New York Jul 21, 06 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)Improper Installation
DescriptionDue DateResolved
Install lagging on both pump engines manifolds as discussed.Aug 21, 06Yes
Resolved DateResolution
Aug 15, 06Installed new lagging.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)Unknown
DescriptionDue DateResolved
Make temporary repairs to Port Navigation light kick pipe, at next drydock maker pernament repairs.Aug 21, 06Yes
Resolved DateResolution
Aug 15, 06Installed new kickpipe.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)Improper Installation
DescriptionDue DateResolved
Remove extension cords and install outlets where needed in ships office.Aug 21, 06Yes
Resolved DateResolution
Aug 15, 06Instaled new outlets.
2598777 STATEN ISLAND, New York Mar 08, 06 Vessel Inspection - Agency Action Complete
2582553 Woods Hole, Massachusetts Feb 09, 06 Vessel Transfer Monitor - Approved Inspection
2572339 STATEN ISLAND, New York May 31, 05 Vessel Inspection - Approved Inspection
2373673 STATEN ISLAND, New York May 31, 05 Vessel Inspection - Agency Action Complete
  4
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)Unknown
DescriptionDue DateResolved
#1 Stbd stripping pump missing drip shield.Jun 07, 05Yes
Resolved DateResolution
Jun 02, 05Drip shield installed
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational SafetyImproper/Lack of Maintenance
DescriptionDue DateResolved
Combustible materials stowed on top of the electrical switchboard.May 31, 05Yes
Resolved DateResolution
May 31, 05Combustibles removed.
SystemSubsystemCause
ElectricalElectric Generation Source (service)Unknown
DescriptionDue DateResolved
Lube oil gauge on generator inoperative.Jun 07, 05Yes
Resolved DateResolution
Jun 02, 05New gauge installed
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)Unknown
DescriptionDue DateResolved
Port and Stbd cargo pumps leaking at the hard pipe on deck.May 31, 05Yes
Resolved DateResolution
May 31, 05Fittings replaced.
2278441 STATEN ISLAND, New York Jan 21, 05 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
As per letter to Sector NY dated 12/23/05, Vsl's #'d relief valves # 1 P/S, 2P, and 4S and have not been tested IAW regs. Have valves properly hydro tested and submit proof of said test to Sector NY prior to usage of cargo pumps they cover. To the satisfaction of USCG Marine Inspector.Yes
Resolved DateResolution
Jul 21, 06Witnessed that this system was permanently disconnected from main system. Pumps will remain in place but will not operate.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
As per letter to Sector NY dated 12/23/05, junction box for #1 stbd cargo pump is not suitable for installation in the required hazard zone. After installation of proper junction box, submit proof to Sector NY prior to usage of cargo pump 1S which it covers. To the satisfaction of USCG Marine Inspector.Yes
Resolved DateResolution
Jul 21, 06Witnessed that this system was permanently disconnected from main system. Pumps will remain in place but will not operate.
2260015 Washington, District of Columbia Dec 15, 04 Vessel Inspection - Security Plan Approved by MSC
2207293 PHILADELPHIA, Pennsylvania Sep 28, 04 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Circuit not labeled.Oct 15, 04Yes
Resolved DateResolution
Oct 01, 04Vessel properly labeled the circuit breaker.
1816492 Baltimore, Maryland Jun 19, 03 Vessel Inspection - Approved Inspection
1667833 STATEN ISLAND, New York Aug 28, 02 Vessel Inspection - Agency Action Complete
1660645 STATEN ISLAND, New York Aug 13, 02 Vessel Inspection - Agency Action Complete
1437942 STATEN ISLAND, New York Aug 16, 01 Vessel Inspection - Agency Action Complete
  4
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Lubricate/free up release pin and hinge for anchor cable stay. Aug 22, 01Yes
Resolved DateResolution
Aug 23, 01
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
Permanently secure refrigerator to deck or bulkhead. Aug 22, 01Yes
Resolved DateResolution
Aug 23, 01
SystemSubsystemCause
DocumentationUnknown
DescriptionDue DateResolved
Provide original COD for USCG inspection. Aug 22, 01Yes
Resolved DateResolution
Aug 23, 01
SystemSubsystemCause
DocumentationUnknown
DescriptionDue DateResolved
Provide original IOPP certificate for USCG signature or apply for new one. Aug 22, 01Yes
Resolved DateResolution
Aug 23, 01
1412284 PHILADELPHIA, Pennsylvania May 11, 01 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineUnknown
DescriptionDue DateResolved
UPON ARRIVAL BROOKLYN, NEW YORK CONDUCT UNDERWATER SURVEY OF BARGE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR AND OCMI NEW YORK. May 16, 01Yes
Resolved DateResolution
May 16, 01
32389 WASHINGTON, District of Columbia May 11, 01 Incident Investigation - Agency Action Complete
1406857 STATEN ISLAND, New York Feb 13, 01 Vessel Inspection - Agency Action Complete
1058655 PHILADELPHIA, Pennsylvania Feb 12, 01 Vessel Inspection - Agency Action Complete
128112 WASHINGTON, District of Columbia Feb 11, 01 Incident Investigation - Agency Action Complete
17873 WASHINGTON, District of Columbia Feb 10, 01 Incident Investigation - Agency Action Complete
1466161 New Orleans, Louisiana Aug 31, 00 Vessel Inspection - Agency Action Complete
Documents Issued Expires Agency
Cargo Authority Attachment November 10,2009 N/A
CERTIFICATE OF DOCUMENTATION June 30,2021 July 31,2022 USCG
Certificate of Inspection May 31,2010 May 31,2015 N/A
Certificate of Inspection - Amended May 31,2010 May 31,2015 N/A
Classification Document July 1,2010 August 31,2015 ABS
International Load Line Certificate July 1,2010 August 31,2015 ABS
International Oil Pollution Prevention Certificate June 25,2008 May 31,2010 N/A
Int'l Oil Poll Prevention, Form B Supplement July 24,2020 July 24,2025 N/A
ISM - Document Of Compliance January 22,2015 May 25,2020 ABS
Load Line Certificate (Coastwise) February 8,2006 August 31,2010 ABS
Stability Letter May 20,2005 N/A
Tonnage Certificate, International May 25,2005 ABS