Polyaigos
Print Q88   
IMO/VIN Callsign Flag Service Year
9306574 SXVZ GREECE Tank Ship 2005
Activity# Port Date Activity - Description Deficiencies
7072228 Mobile, Alabama Oct 12, 20 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
Each tankship with a VCS must be fitted with a pressure sensing device which has a high pressure and low pressure alarm that gives an audible and visual warning on the vessel where the cargo transfer is controlled. PSCO noted that the high and low audible and visual alarms were inoperable when tested.No
6923074 WASHINGTON, District of Columbia Feb 21, 20 Incident Investigation - Agency Action Complete
6831518 San Pedro, California Oct 16, 19 Vessel Inspection - Approved Inspection
6542609 CORPUS CHRISTI, Texas Sep 21, 18 Vessel Inspection - Approved Inspection
6543103 CORPUS CHRISTI, Texas Sep 18, 18 Vessel Inspection - Administrative Action
6462011 Mobile, Alabama Jul 13, 18 Vessel Inspection - Approved Inspection
6461991 Mobile, Alabama Jul 01, 18 Vessel Inspection - Approved Inspection
6356738 PHILADELPHIA, Pennsylvania Feb 17, 18 Vessel Inspection - Agency Action Complete
6269195 Port Arthur, Texas Sep 19, 17 Vessel Inspection - Approved Inspection
6240485 WASHINGTON, District of Columbia Jul 26, 17 Incident Investigation - Agency Action Complete
6002897 STATEN ISLAND, New York Sep 17, 16 Vessel Inspection - Approved Inspection
5725814 New Orleans, Louisiana Sep 29, 15 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
PersonnelCertificates/Documents/LicensesInvalid
DescriptionDue DateResolved
0220-CERTIFICATES OF COMPENTENCY- Each administration shall ensure that the provisions of this regulation are complied with by endorsement in accordance with regulation I/2, paragraph 7, a certificate issued by or under the authority of another Party to a Master, Officer or Radio operator. PSCO observed that the 2nd Engineer did not have Greek endorsement on board.- STCW Annex I/10Sep 29, 15Yes
Resolved DateResolution
Sep 30, 15Received, reviewed and accepted Endorsement from Hellenic Republic.
5235154 WASHINGTON, District of Columbia Sep 03, 15 Incident Investigation - Agency Action Complete
4978096 Ponce, Puerto Rico Sep 13, 14 Vessel Inspection - Approved Inspection
4673990 CORPUS CHRISTI, Texas Aug 15, 13 Vessel Inspection - Approved Inspection
4630188 WASHINGTON, District of Columbia Jun 23, 13 Incident Investigation - Agency Action Complete
4611980 New Orleans, Louisiana Jun 05, 13 Vessel Inspection - Administrative Action
4547578 PORT ARANSAS, Texas Mar 11, 13 Boarding - Agency Action Complete
4544384 CORPUS CHRISTI, Texas Mar 06, 13 Vessel Operational Control - Agency Action Complete
4525967 New Orleans, Louisiana Jan 31, 13 Vessel Inspection - Administrative Action
4503135 New Orleans, Louisiana Dec 29, 12 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
0715 - Detection - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO noted while in Cargo Control Room that the fixed gas detection system is alarming when turned on. SOLAS 74a I/11Jan 12, 13Yes
Resolved DateResolution
Jan 31, 13Received class report from Lloyd''s Register satisfying requirement.
SystemSubsystemCause
Operations/ManagementPollution
DescriptionDue DateResolved
2430 - >1% m/m Sulfur Content - While ships are operating within an emission control area (ECA), the sulfur content used on board ships shall not exceed 1%. The PSCO discovered that the vessel has been operating within the North American ECA from 22/12/12 to 29/12/12 utilizing fuel oil that does not comply with the MARPOL Annex VI ECA sulfur limits. MARPOL Annex VI, Reg 14.4; 40CFR1043.60Dec 29, 12Yes
Resolved DateResolution
Dec 29, 12Documentation was provided to the PSCO from the master showing attempts to obtain compliant fuel and that compliant fuel will be taken onboard while in the ECA.
4481523 WASHINGTON, District of Columbia Nov 01, 12 Incident Investigation - Agency Action Complete
4474612 Port Arthur, Texas Oct 29, 12 Vessel Inspection - Approved Inspection
4444370 San Pedro, California Sep 26, 12 Vessel Inspection - Agency Action Complete
  5
SystemSubsystemCause
LifesavingEmbarkation Appliances/Stations
DescriptionDue DateResolved
0520 Muster and embarkation stations shall be adequately illuminated by lighting supplied by the emergency source of electrical power. Lighting located at embarkation station did not illuminate. Crew changed light bulb and lighting now operational. 74 SOLAS (09 Cons) CH.III/ 11.4 10cSep 26, 12Yes
Resolved DateResolution
Oct 26, 12Crew Changed light bulbs. Lighting operational. Deficiency rectified on the spot.
SystemSubsystemCause
LifesavingLifebuoys
DescriptionDue DateResolved
0650 Not less than half of the total number of life buoys shall be provided with self ignighting lighta. 04 out of the 14 life buoys are fitted with self ignighting lights. 74 SOLAS (09 Cons) CH. III/7.1.3 16COct 10, 12Yes
Resolved DateResolution
Oct 29, 12Received Class Report attesting to proper repairs.
SystemSubsystemCause
Fire FightingFiremans Outfit
DescriptionDue DateResolved
0735: Fire fighting outfits shall comply with the fire safety systems code. The protective clothing of 03 of the 04 fire fighting out fits can no longer protect the skin from the heat radiating from the fire. Fix prior to cargo operations. 74 SOLAS (09 cons) CH. II-2/ 10.10.1 17A/CYes
Resolved DateResolution
Sep 27, 12Received satisfactory CLASS Report #DOC09271-019 attesting to the delivery of 03 fire fighting outfits onboard vessel and ready for service.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
1099 On a tank ship, each cargo tank must be equipped with an overfill device that meets the requirements for tank overfill alarms under 46 CFR 39.20-7. Overfill alarm label is not visible from cargo deck area. Fix prior to loading cargo.Oct 28, 12Yes
Resolved DateResolution
Oct 29, 12Received Class Report attesting to proper repairs.
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
1850 After any survey under regulations 7,8,9, or 10 has been completed, no change shall be made in the structural arangements, machinery and equipment. Scrubber has been welded on lower part as per Hamworthy Moss AS daily report and no class surrvey has been completed after repairs. Scubber sight glass leaking water. Wet filter has plastic zip-tie fasteners; some broken. 74 SOLAS (09 Cons) I/11Yes
Resolved DateResolution
Oct 22, 12Received Class Report attesting to proper repairs.
4258235 PHILADELPHIA, Pennsylvania Mar 07, 12 Vessel Inspection - Approved Inspection
4239144 CORPUS CHRISTI, Texas Feb 06, 12 Vessel Inspection - Approved Inspection
4155916 San Pedro, California Oct 04, 11 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringDiesel Engine (propulsion-direct drive)
DescriptionDue DateResolved
Code 1410: Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. While approaching anchorage, engine did not respond to dead slow astern command, nor to multiple further attempts, all while operating on MGO/DMA fuel.Oct 04, 11Yes
Resolved DateResolution
Oct 04, 11Class Lloyd''s Register report received attesting to satisfactory condition of machinery; cause attributed to MGO operation. Upon recommendation by manufacturer, digital governor unit setting adjusted; satisfactory tests start, ahead, astern, & stop.
4162480 WASHINGTON, District of Columbia Oct 03, 11 Incident Investigation - Agency Action Complete
4120939 Port Arthur, Texas Aug 19, 11 Boarding - Agency Action Complete
3931782 CORPUS CHRISTI, Texas Jan 21, 11 Vessel Inspection - Approved Inspection
3866535 TEXAS CITY, Texas Oct 12, 10 Vessel Inspection - Agency Action Complete
3855722 TEXAS CITY, Texas Sep 28, 10 Boarding - Agency Action Complete
3746363 STATEN ISLAND, New York May 24, 10 Vessel Inspection - Administrative Action
3708480 New Orleans, Louisiana Apr 04, 10 Vessel Inspection - Administrative Action
3594578 TEXAS CITY, Texas Oct 04, 09 Vessel Inspection - Approved Inspection
3361645 ST PETERSBURG, Florida Nov 12, 08 Vessel Inspection - Approved Inspection
3361645 Tampa, Florida Nov 12, 08 Vessel Inspection - Approved Inspection
3344761 San Francisco, California Oct 14, 08 Vessel Inspection - Approved Inspection
3171779 New Orleans, Louisiana Mar 26, 08 Vessel Inspection - Administrative Action
3126654 Coram, New York Jan 07, 08 Vessel Inspection - Agency Action Complete
3089764 San Francisco, California Oct 30, 07 Vessel Inspection - Approved Inspection
3082832 San Francisco, California Oct 18, 07 Boarding - Agency Action Complete
3067576 Christiansted, Virgin Islands Sep 27, 07 Enforcement - Payment Received
3067213 Christiansted, Virgin Islands Sep 26, 07 Boarding - Agency Action Complete
3066719 Christiansted, Virgin Islands Sep 26, 07 Vessel Operational Control - Agency Action Complete
3063095 Christiansted, Virgin Islands Sep 26, 07 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
Vessel has no record of calibration on installed gas detection system. Prove proper calibration of installed gas detection system to the satisfaction of the attending Marine Inspector within 7 days.Oct 04, 07Yes
Resolved DateResolution
Oct 01, 07CWO Mahony attended vessel and cleared def.
2906700 Jacksonville, Florida Apr 12, 07 Boarding - Agency Action Complete
2904633 Jacksonville, Florida Apr 09, 07 Vessel Operational Control - Agency Action Complete
2866545 TEXAS CITY, Texas Feb 03, 07 Vessel Inspection - Approved Inspection
2861286 Port Arthur, Texas Jan 24, 07 Boarding - Agency Action Complete
2827021 CORPUS CHRISTI, Texas Nov 22, 06 Vessel Inspection - Approved Inspection
2803398 New Orleans, Louisiana Oct 24, 06 Boarding - Agency Action Complete
2577227 STATEN ISLAND, New York Feb 01, 06 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
ElectricalLighting (service)
DescriptionDue DateResolved
Forward mast cargo deck lights not working. Prove proper operation of the lights to the satisfaction of Class.Mar 01, 06Yes
Resolved DateResolution
Feb 04, 06Received report from American Bureau Of Shipping, #679126, showing that item has been dealt with.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Storm damage to hydraulic control lines support run for Framo pumps. Prior the vessel departing the port vessel to have control lines examine by Class and provide report to the USCG.Feb 01, 06Yes
Resolved DateResolution
Feb 04, 06Received report from American Bureau Of Shipping, #679126, showing that item has been dealt with.
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Vessel had storm damage in way of frame 90 forward, which resulted in damage to catwalk, electrical pipe run, support brackets, COW piping, and #1 port cargo P/V vent bent. Prior to the vessel's departure from port, vessel to have class examine this are to ensure that ship is fit for route and service.Feb 01, 06Yes
Resolved DateResolution
Feb 04, 06Received report from American Bureau Of Shipping, #679126, showing that item has been dealt with.
2577193 STATEN ISLAND, New York Feb 01, 06 Boarding - Agency Action Complete
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel September 21,2018 September 21,2020 N/A
Classification Document December 16,2015 November 21,2020 LR
COC-TVE Annual September 29,2015 September 29,2016 N/A
COC-TVE Renewal September 26,2007 September 26,2009 N/A
International Load Line Certificate December 16,2015 November 21,2020 LR
International Oil Pollution Prevention Certificate July 15,2016 November 21,2020 LR
ISM - Document Of Compliance October 25,2019 November 4,2024 LR
ISM - Safety Management Certificate September 13,2007 March 12,2008 N/A
Minimum Safe Manning Document June 16,2017 N/A
SOLAS Cargo Ship Safety Construction Certificate December 10,2010 November 22,2015 LR
SOLAS Cargo Ship Safety Equipment Certificate December 16,2015 November 21,2020 LR
SOLAS Cargo Ship Safety Radio Certificate December 5,2015 November 21,2020 LR
Tonnage Certificate, International September 12,2007 December 11,2007 N/A