Print Q88   
IMO/VIN Callsign Flag Service Year
9358280 9V7608 BELGIUM Tank Ship 2008
Activity# Port Date Activity - Description Deficiencies
6633175 TEXAS CITY, Texas Mar 14, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The condition of the ship and its equipment shall be maintained to comform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. It was observed that 03 supports for control lines for cargo line valves amidships were completely wasted. It was observed that due to lack of support the lines were braking free from sheathing and suffering damage. 74 SOLAS (14) I/11(a) 16cMar 28, 19Yes
Resolved DateResolution
Mar 22, 19Vessel submitted report/root cause analysis with pictures demonstrating the new cable trails that were installed to rectify the deficiency. See deficiency documents.
5806088 Morgan City, Louisiana Jan 29, 16 Vessel Inspection - Approved Inspection
5798044 Morgan City, Louisiana Jan 17, 16 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringSteering Gear SystemInvalid
DescriptionDue DateResolved
Vessel rudder not responding to steering operation. Vessel is unable to maneuver due to failure of rudder movement.Feb 16, 16Yes
Resolved DateResolution
Jan 29, 16Rudder function tested underway to the satisfaction of class.
4581485 Morgan City, Louisiana May 02, 13 Vessel Inspection - Approved Inspection
4140868 Morgan City, Louisiana Sep 12, 11 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
LifesavingRescue BoatImproper/Lack of Maintenance
DescriptionDue DateResolved
SOLAS 09 CH III/20.2 Before the ship leaves port and at all times during the voyage, all life-saving applicances shall be in working order and ready for immediate use. Rescue boat battery was not working, therefore it was not ready for immediate use.Yes
Resolved DateResolution
Sep 15, 11Vessel captain e-mailed MSU Morgan City personnel a receipt of delivery for the rescue boat battery.
3653684 TEXAS CITY, Texas Dec 21, 09 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Classification Document July 6,2018 September 26,2023 LR
COC-TVE Renewal September 12,2011 September 12,2013 N/A
International Load Line Certificate August 10,2018 September 26,2023 LR
International Oil Pollution Prevention Certificate August 29,2018 September 26,2023 BE
ISM - Document Of Compliance October 16,2017 March 9,2021 BE
ISM - Safety Management Certificate October 30,2017 March 29,2020 BE
Minimum Safe Manning Document August 29,2018 September 26,2023 BE
SOLAS Cargo Ship Safety Construction Certificate August 10,2018 September 26,2023 LR
SOLAS Cargo Ship Safety Equipment Certificate August 29,2018 September 26,2023 BE
SOLAS Cargo Ship Safety Radio Certificate August 29,2018 September 26,2023 BE
Tonnage Certificate, International January 11,2017 BE