Maritime Suzanne
Print Q88   
IMO/VIN Callsign Flag Service Year
9221023 VRXL9 HONG KONG Tank Ship 2002
Activity# Port Date Activity - Description Deficiencies
6324897 TEXAS CITY, Texas Dec 28, 17 Vessel Inspection - Approved Inspection
6020228 Mobile, Alabama Oct 18, 16 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)Damaged By Earlier Event
DescriptionDue DateResolved
1930-tank washing equipment-THE EQUIPMENT AND OPERATIONS OF SHIPS CERTIFIED TO CARRY NLS IN BULK IDENTIFIED IN CHAP 17 OF THE IBC CODE SHALL BE IN COMPLIANCE WITH THE IBC CODE AND BE SURVEYED AND CERTIFIED AS PROVIDED FOR THAT CODE. THE TANK WASHING WATER SUPPULY LINE FOR TANK 3S HAS A SOFT PATCH FOR A TEMP REPAIR AND INDENTATION FROM PREVIOUS DAMAGE. -MARPOL ANNEX II/11 -40cOct 18, 16Yes
Resolved DateResolution
Oct 21, 16Pipe section replaced and tested; TEST SAT.
5720081 New Orleans, Louisiana Sep 11, 15 Vessel Operational Control - Agency Action Complete
5220248 WASHINGTON, District of Columbia Aug 17, 15 Incident Investigation - Agency Action Complete
5196248 Mobile, Alabama Jul 26, 15 Vessel Inspection - Approved Inspection
5011054 Mobile, Alabama Oct 26, 14 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
Construction/LoadlineStructuresImproper/Lack of Maintenance
DescriptionDue DateResolved
Code: 0510 Cite: 74SOLAS(2001) II-2/3.3 Action Taken: 40ac In combination carriers all cargo spaces and any enclosed spaces adjacent to cargo spaces shall be capable of mechanically ventilated. The mechanical ventilation for the sample locker room on the starboard side of the cargo deck was found inoperable.Yes
Resolved DateResolution
Aug 02, 15Deficiency was resolved to the satisfaction of the attending Coast Guard Marine Inspector.
SystemSubsystemCause
Construction/LoadlineStructuresImproper/Lack of Maintenance
DescriptionDue DateResolved
Code: 1270 Cite: ICLL(1966) II/12(1) Action Taken: 40ac All access openings in bulkheads at ends of enclosed superstructures shall be weathertight when closed. Both the port and starboard weathertight doors on the 2nd Poop Deck were found to not be weathertight.Yes
Resolved DateResolution
Aug 02, 15Deficiency was resolved to the satisfaction of the attending Coast Guard Marine Inspector.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational SafetyImproper/Lack of Maintenance
DescriptionDue DateResolved
Code: 1299 Cite: ICLL(1966) II/25(3) Action Taken: 40ac Guard rails fitted on superstructure and freeboard deck shall have at least three courses. Chains fitted between two fixed stanchions and/or bulwarks are acceptable in lieu of guard rails. Above the dehumidifier room on the port side, no chains are provided in lieu of guard rails. Deteriorated rails were found in way of PV breaker.Yes
Resolved DateResolution
Aug 02, 15Deficiency was resolved to the satisfaction of the attending Coast Guard Marine Inspector.
5008579 Houston, Texas Oct 20, 14 Vessel Inspection - Failure to Show
5002515 San Diego, California Oct 09, 14 Vessel Inspection - Approved Inspection
4535083 Houston, Texas Feb 18, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
ElectricalElectric Generation Source (emergency)
DescriptionDue DateResolved
0950 - Electrical equpiment in general - a second source of energy shall be provided for an additional three starts within 30 minutes unless manual starting can be demonstrated to be effective. Second means to start emergency generator failed. - 74SOLAS (01)II-1/44.2Yes
Resolved DateResolution
Feb 21, 13Vessel submitted class report attesting to the proper repair and operation of the emergency generator.
4192689 Victoria, Texas Nov 21, 11 Vessel Inspection - Approved Inspection
4176922 North Charleston, South Carolina Oct 27, 11 Vessel Inspection - Approved Inspection
4082588 PORT OCONNOR, Texas Jul 15, 11 Boarding - Agency Action Complete
3844242 Houston, Texas Sep 07, 10 Vessel Inspection - Approved Inspection
3387236 Houston, Texas Jan 01, 09 Vessel Operational Control - Approved Inspection
3172792 Houston, Texas Mar 28, 08 Vessel Inspection - Approved Inspection
3074661 New Orleans, Louisiana Oct 07, 07 Vessel Inspection - Administrative Action
3073617 New Orleans, Louisiana Oct 05, 07 Vessel Operational Control - Agency Action Complete
3071940 Houston, Texas Oct 03, 07 Vessel Operational Control - Agency Action Complete
3069488 Victoria, Texas Sep 30, 07 Vessel Inspection - Agency Action Complete
2880637 New Orleans, Louisiana Mar 05, 07 Boarding - Agency Action Complete
2865614 San Pedro, California Feb 01, 07 Boarding - Agency Action Complete
2862403 Warrenton, Oregon Jan 27, 07 Vessel Inspection - Approved Inspection
2496484 Victoria, Texas Sep 19, 05 Vessel Inspection - Approved Inspection
2366228 Houston, Texas May 20, 05 Vessel Inspection - Approved Inspection
2360488 Houston, Texas May 17, 05 Vessel Inspection - Approved Inspection
2184494 Victoria, Texas Sep 03, 04 Vessel Inspection - Agency Action Complete
2177075 Miami Beach, Florida Aug 26, 04 Vessel Inspection - Approved Inspection
1989561 Victoria, Texas Jan 20, 04 Vessel Inspection - Approved Inspection
1763693 TEXAS CITY, Texas Mar 27, 03 Vessel Inspection - Approved Inspection
1764306 TEXAS CITY, Texas Mar 26, 03 Boarding - Agency Action Complete
1681736 San Pedro, California Sep 27, 02 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Chemical Carrier September 3,2004 September 3,2006 N/A
Certificate of Compliance - Tank Vessel October 18,2016 October 18,2018 N/A
Certificate of Fitness - Chemical Carrier December 28,2017 October 18,2018 N/A
Classification Document June 15,2017 May 8,2022 ABS
COC-TVE Renewal January 27,2007 January 27,2009 N/A
International Certificate of Fitness - Chemical June 15,2017 May 8,2022 ABS
International Load Line Certificate June 15,2017 May 8,2022 ABS
International Oil Pollution Prevention Certificate June 15,2017 May 8,2022 ABS
ISM - Document Of Compliance March 12,2007 March 11,2008 N/A
ISM - Safety Management Certificate June 15,2017 September 3,2022 ABS
Minimum Safe Manning Document October 6,2014 HK
SOLAS Cargo Ship Safety Construction Certificate June 15,2017 May 8,2022 ABS
SOLAS Cargo Ship Safety Equipment Certificate June 15,2017 May 8,2022 ABS
SOLAS Cargo Ship Safety Radio Certificate June 15,2017 May 8,2022 ABS
Tonnage Certificate, International March 6,2002 HK