Activity# Port Date Activity - Description Deficiencies
7199941 North Charleston, South Carolina May 23, 21 Vessel Inspection - Approved Inspection
6858256 WASHINGTON, District of Columbia Nov 19, 19 Incident Investigation - Agency Action Complete
6854174 BOSTON, Massachusetts Nov 12, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The main steering gear shall be capable of putting rudder from 30 degrees to 35 degrees at max service speed. While testing the Number 2 Steering Pump in follow-up mode, the rudder was not able to be returned to midship. 74 SOLAS (14) II-1/29.3.2Nov 12, 19Yes
Resolved DateResolution
Nov 14, 19A.G Marine replaced feedback potentiometer. Received class report.
6853815 SOUTH PORTLAND, Maine Nov 12, 19 Vessel Operational Control - Agency Action Complete
6700291 Houston, Texas Jun 14, 19 Vessel Inspection - Approved Inspection
6431468 New Orleans, Louisiana Jun 01, 18 Vessel Inspection - Agency Action Complete
6431434 New Orleans, Louisiana Jun 01, 18 Vessel Inspection - Approved Inspection
4484410 FPO, AP, Guam Nov 15, 12 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
All electrical cables and wiring external to equipment shall be at least a flame-retardant type and shall be so installed as to not impair their original flame-retarding properties. Electrical power supply wiring to IGG gas regulating valve and IGG temperature sensor exposed and chaffing.SOLAS74(04Cons) II-I/45.5.2Yes
Resolved DateResolution
Nov 15, 12Corrected on the spot.
4150781 Houston, Texas Sep 21, 11 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
LifesavingLaunching Appliances
DescriptionDue DateResolved
Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off power before davit arms reach the stops. Both limit switches on the starboard lifeboat were found to be inoperable. SOLAS 2004 CH. III/16.1 LSA CH. VI/6.1.2.7 70aYes
Resolved DateResolution
Nov 15, 12Witnessed satisfactoy abandon ship drill lowering starboard lifeboat to main deck. Verified function of both limit switches and found to be operating properly.
3945083 CAPE CANAVERAL, Florida Feb 14, 11 Boarding - Agency Action Complete
3943293 Jacksonville, Florida Feb 11, 11 Vessel Operational Control - Agency Action Complete
3930630 NEW HAVEN, Connecticut Jan 21, 11 Vessel Operational Control - Approved Inspection
3848760 Houston, Texas Sep 13, 10 Vessel Inspection - Approved Inspection
3830757 Houston, Texas Aug 22, 10 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
LifesavingLifeboat
DescriptionDue DateResolved
Each survival craft shall be stowed in a state of continuous readiness so that crew members can carry out preparations for embarkation and launching in less than 5 minutes. Survival craft release hooks in the released position. When the crew released the gripes to lower the lifeboat, unmanned, to embarkation deck, the hooks released and the lifeboat tumbled into the water.Aug 22, 10Yes
Resolved DateResolution
Aug 31, 10Received attestation that the lifeboat is repaired and be returned to the vessel.
SystemSubsystemCause
Deck/CargoMooring/Anchoring
DescriptionDue DateResolved
Piping for the mooring winch cooling lines in steering gear room spraying water from fittings. Piping systems discharge line shall be of a design and construction adequate for the services for which they are intended.Aug 22, 10Yes
Resolved DateResolution
Sep 13, 10The leaking mooring winch cooling lines was renewed with a new pipe (50A x 115mmL) and confirmed by the attending class surveyor.
SystemSubsystemCause
Deck/CargoMooring/Anchoring
DescriptionDue DateResolved
The brake pad on the port side winch is frayed presenting a danger to the ship or persons aboard. Equipment shall be maintained to conform with the provisions of the present regulation following survey.Aug 22, 10Yes
Resolved DateResolution
Sep 13, 10The frayed end of the brake pad on the port winch aws renewed with a new one and a brake holding power test (210bar) was conducted. The attending class surveyor confirmed that everything was in order.
3833342 WASHINGTON, District of Columbia Aug 22, 10 Incident Investigation - Agency Action Complete
3047497 San Pedro, California Sep 03, 07 Vessel Inspection - Approved Inspection
2640974 FPO, AP, Guam May 05, 06 Vessel Inspection - Approved Inspection
2527337 FPO, AP, Guam Nov 03, 05 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
DocumentationSafety/Response Plans/Programs
DescriptionDue DateResolved
Vessel Response Plan onboard but not approved by Commandant.Yes
Resolved DateResolution
May 05, 06
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel November 15,2012 November 15,2014 USCG
Classification Document February 26,2021 March 21,2025 KR
COC-TVE Annual June 14,2019 June 6,2020 HOUMS
COC-TVE Renewal September 3,2007 September 3,2009 N/A
International Load Line Certificate February 26,2021 March 21,2025 KR
International Oil Pollution Prevention Certificate May 20,2019 July 31,2022 KR
ISM - Document Of Compliance November 21,2017 December 31,2022 LR
ISM - Safety Management Certificate January 4,2018 January 3,2023 LR
Minimum Safe Manning Document July 31,2017 LR
NLS Certificate August 1,2017 March 20,2020 KR
SOLAS Cargo Ship Safety Construction Certificate February 26,2021 March 21,2025 KR
SOLAS Cargo Ship Safety Equipment Certificate February 26,2021 March 21,2025 KR
SOLAS Cargo Ship Safety Radio Certificate February 26,2021 March 21,2025 KR
Tonnage Certificate, International August 22,2005 ABS