Victorious
Print Q88   
IMO/VIN Callsign Flag Service Year
9290919 V7A2490 MARSHALL ISLANDS Tank Ship 2005
Activity# Port Date Activity - Description Deficiencies
6828495 Houston, Texas Oct 12, 19 Vessel Inspection - Approved Inspection
6824911 Houston, Texas Sep 30, 19 Boarding - Agency Action Complete
6824894 Houston, Texas Sep 30, 19 Boarding - Agency Action Complete
6644569 STATEN ISLAND, New York Mar 18, 19 Vessel Operational Control - Agency Action Complete
6556507 CORPUS CHRISTI, Texas Oct 13, 18 Vessel Inspection - Approved Inspection
4501531 Port Arthur, Texas Dec 20, 12 Vessel Inspection - Approved Inspection
4231387 TEXAS CITY, Texas Jan 30, 12 Vessel Inspection - Approved Inspection
3864729 Houston, Texas Oct 06, 10 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
As currently constructed the ventilation system in the engine room around the O2 censoring equipment to the inert gas generator is not operating as appropriate for the purpose of that machinery space. Temporary ventilation piping has been installed to prevent O2 sensor failure. cite: SOLAS 74/2004 cons. II-I, Reg 35Yes
Resolved DateResolution
Oct 10, 10Recieved class report. Temporary piping installed for ventilation has been removed. O2 sensing equipment for inert gas generator was tested sat.
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
Each operation in the oil record book shall be fully recorded without delay, so that all entries in the book appropriate to that operation and completed. The max capacitity of the oily water separator is 5.0m3/hour. On July 19 2010 the Oil record book records start 1300 end 1600 and processed 18m3; On July 31 2010 started 1400 end 1700 and processed 17m3. This exceeds the maximum output of 5 m3/hrNov 05, 10Yes
Resolved DateResolution
Oct 10, 10Recieved Flag report. Attested to correction of oil record book and proper operation of ows.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Ignition sources shall be restricted. The fire bricks inside the incinerator have collapsed and no longer protect the incinerator casing creating a significant fire hazard. cite: SOLAS 74/2004 cons. II-I Reg 4.1.4Yes
Resolved DateResolution
Oct 10, 10Recieved class report. Fire bricks inside of incinerator were repaired in accordance with manufacturer recommendation and found sat.
SystemSubsystemCause
EngineeringFuel Oil Service System
DescriptionDue DateResolved
The machinery and associated piping shall be of a design and construction adequate for the service for which they are intended. The fuel oil leakage piping on main engine has an additional line installed which is not indicated on approved fuel oil service system diagram. cite: SOLAS 74/2004 cons. II-I Reg 26.1Nov 05, 10Yes
Resolved DateResolution
Oct 10, 10Recieved class report. Relevent piping removed from main engine fuel oil system and flanges blanked.
3861073 TEXAS CITY, Texas Oct 05, 10 Boarding - Agency Action Complete
3425279 Port Arthur, Texas Feb 27, 09 Vessel Inspection - Approved Inspection
3416040 New Orleans, Louisiana Feb 15, 09 Vessel Inspection - Approved Inspection
3368322 WASHINGTON, District of Columbia Nov 24, 08 Incident Investigation - Agency Action Complete
3365367 Houston, Texas Nov 18, 08 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
PersonnelManning/QualificationsUnknown
DescriptionDue DateResolved
The Captain of the Port Sector Houston Galveston has been notified of the marine casualty aboard your vessel with regards to the ships master. Prior to the vessels departed from the Port of Houston, submit to this office: Documentation attesting to the proper manning of the vessel.Yes
Resolved DateResolution
Nov 20, 08PSCO received documentation of proper manning, new master onboard. The vessel has been released from OPCON.
3360657 Houston, Texas Nov 10, 08 Vessel Inspection - Agency Action Complete
2897065 SOUTH PORTLAND, Maine Mar 28, 07 Vessel Inspection - Approved Inspection
2842920 Christiansted, Virgin Islands Dec 19, 06 Vessel Inspection - Approved Inspection
2821540 Port Arthur, Texas Nov 15, 06 Boarding - Agency Action Complete
2806149 SOUTH PORTLAND, Maine Oct 23, 06 Vessel Operational Control - Agency Action Complete
2807789 SOUTH PORTLAND, Maine Oct 21, 06 Boarding - Agency Action Complete
2676144 ST PETERSBURG, Florida Jun 11, 06 Vessel Inspection - Agency Action Complete
2676144 Tampa, Florida Jun 11, 06 Vessel Inspection - Agency Action Complete
2673368 Port Arthur, Texas Jun 07, 06 Vessel Inspection - Approved Inspection
2612894 Houston, Texas Mar 30, 06 Vessel Inspection - Agency Action Complete
2561910 PHILADELPHIA, Pennsylvania Jan 06, 06 Vessel Inspection - Approved Inspection
2525811 CORPUS CHRISTI, Texas Oct 31, 05 Enforcement - Payment Received
2494008 CORPUS CHRISTI, Texas Sep 16, 05 Boarding - Agency Action Complete
2502122 WASHINGTON, District of Columbia Sep 16, 05 Incident Investigation - Agency Action Complete
2339415 San Juan, Puerto Rico Apr 21, 05 Vessel Inspection - Approved Inspection
2323758 North Charleston, South Carolina Mar 31, 05 Vessel Inspection - Approved Inspection
2321921 San Juan, Puerto Rico Mar 28, 05 Vessel Inspection - Approved Inspection
  6
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational SafetyImproper/Lack of Maintenance
DescriptionDue DateResolved
Both portable oxygen analysers inop due to dead batteries. Machines left on during last use.Yes
Resolved DateResolution
Mar 28, 05New batteries installed.
SystemSubsystemCause
DocumentationCertificates/DocumentsUnknown
DescriptionDue DateResolved
Flag or Class to indicate vessel type on Page 1 of the IOPP. Currently "Type of Ship" is not indicated.Yes
Resolved DateResolution
Apr 21, 05
SystemSubsystemCause
Deck/CargoVapor Control SystemsImproper Installation
DescriptionDue DateResolved
Install permanently fixed stud on all manifold Vapor Control Flanges. Adjustable studs are not acceptable.Yes
Resolved DateResolution
Apr 02, 05all sat.
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Provide attachment for Category C & D Oil- Like NLS cargoes as per IOPP Form B. Vsl shall not carry Oil-like NLS cargoes until attachement is on board. See Act 2321921 for details.Yes
Resolved DateResolution
Apr 21, 05
SystemSubsystemCause
DocumentationManuals/Policy DocumentationUnknown
DescriptionDue DateResolved
Provide current copies of 46 CFR 35, 150, and 150 as per 46CFR 153.905.Yes
Resolved DateResolution
Apr 02, 05copies of 46 CFR present, all sat.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention EquipmentImproper Installation
DescriptionDue DateResolved
Remove the crossover connection at the OWS overboard discharge piping, after the 3-way valve that was installed in the shipyard during new construction. Piping arrangement differs from manufacturer's specifications. See Act 2321921 for details.Yes
Resolved DateResolution
Apr 02, 05piping removed, all sat
2320128 San Juan, Puerto Rico Mar 26, 05 Vessel Operational Control - Agency Action Complete
Documents Issued Expires Agency
Certificate of Fitness - Chemical Carrier June 30,2019 November 29,2019 DNV GL
Classification Document June 30,2019 September 29,2020 DNV GL
International Certificate of Fitness - Chemical October 13,2017 January 2,2020 LR
International Load Line Certificate June 30,2019 January 2,2020 DNV GL
International Oil Pollution Prevention Certificate June 30,2019 July 15,2022 DNV GL
ISM - Document Of Compliance January 17,2019 May 21,2023 DNV GL
ISM - Safety Management Certificate July 16,2017 July 15,2022 ABS
Minimum Safe Manning Document February 11,2017 February 10,2022 BS
SOLAS Cargo Ship Safety Certificate June 30,2019 January 20,2020 DNV GL
SOLAS Cargo Ship Safety Construction Certificate February 11,2017 January 2,2020 LR
SOLAS Cargo Ship Safety Equipment Certificate June 30,2019 January 2,2020 DNV GL
SOLAS Cargo Ship Safety Radio Certificate June 30,2019 January 2,2020 DNV GL
Tonnage Certificate, International July 1,2019 DNV GL