Print Q88   
IMO/VIN Callsign Flag Service Year
9323364 V7LO2 MARSHALL ISLANDS Tank Ship 2007
Activity# Port Date Activity - Description Deficiencies
7123705 STATEN ISLAND, New York Jan 13, 21 Vessel Inspection - Approved Inspection
6941296 Port Arthur, Texas Apr 20, 20 Vessel Inspection - Approved Inspection
6909473 Port Arthur, Texas Feb 14, 20 Boarding - Agency Action Complete
6906509 TEXAS CITY, Texas Feb 11, 20 Vessel Inspection - Agency Action Complete
6898569 Port Arthur, Texas Jan 31, 20 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high level alarm required by paragraph C1. Four cargo tanks are currently not alarming at high level (95%). Crew will conduct manual soundings on these tanks IAW shipboard procedures/sms. Request class visit to replace/calibrate all cargo tank leveling alarms as peroperating procedures.Mar 01, 20Yes
Resolved DateResolution
Feb 10, 20Received Class report. All high level alarms operational. See attached report.
SystemSubsystemCause
12 - Dangerous GoodsN/A - No SubsystemDamaged By Earlier Event
DescriptionDue DateResolved
Ships carrying cargoes in chapter 17 shall have onboard sufficient but not less than three complete sets of safety equipment. Ship currently has 02 out of 03 complete sets. Hole was spotted in the foot of one chemical suit, with no extras on board.Mar 01, 20Yes
Resolved DateResolution
Apr 20, 20Vessel purchased and provided onboard 02 Chemical Protective suits for use by the crew on to the satisfaction of the lead FCTV inspector. Cleared.
6621512 STATEN ISLAND, New York Feb 07, 19 Vessel Inspection - Agency Action Complete
6586557 Lake Charles, Louisiana Dec 01, 18 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
11104 - Before ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Rescue boat engine will not engage forward or reverse due to broken shift linkage.Dec 01, 18Yes
Resolved DateResolution
Dec 01, 18Vessel made repairs, class visited vessel to certify repairs.
6318341 NEW HAVEN, Connecticut Dec 05, 17 Vessel Inspection - Approved Inspection
6043558 STATEN ISLAND, New York Nov 18, 16 Vessel Inspection - Approved Inspection
5183091 STATEN ISLAND, New York Jul 13, 15 Vessel Inspection - Approved Inspection
4843606 STATEN ISLAND, New York Apr 25, 14 Vessel Inspection - Agency Action Complete
4820864 STATEN ISLAND, New York Mar 22, 14 Vessel Inspection - Approved Inspection
4590652 TEXAS CITY, Texas May 13, 13 Boarding - Agency Action Complete
4525252 Port Arthur, Texas Feb 04, 13 Vessel Inspection - Approved Inspection
3782031 STATEN ISLAND, New York Jul 01, 10 Vessel Inspection - Approved Inspection
3209625 Houston, Texas May 18, 08 Vessel Inspection - Agency Action Complete
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel July 1,2010 July 1,2012 N/A
Certificate of Fitness - Chemical Carrier September 12,2015 September 11,2020 LR
Classification Document September 12,2015 September 11,2020 LR
International Load Line Certificate September 12,2015 September 11,2020 LR
International Oil Pollution Prevention Certificate October 16,2018 September 11,2020 LR
ISM - Document Of Compliance February 20,2018 January 4,2020 LR
ISM - Safety Management Certificate February 20,2018 December 14,2022 LR
Minimum Safe Manning Document July 31,2007 MH
SOLAS Cargo Ship Safety Certificate September 10,2020 September 10,2025 LR
SOLAS Cargo Ship Safety Construction Certificate September 12,2015 September 11,2020 LR
SOLAS Cargo Ship Safety Equipment Certificate September 10,2020 September 11,2025 LR
SOLAS Cargo Ship Safety Radio Certificate July 10,2012 July 30,2017 LR
Tonnage Certificate, International July 13,2007 DNV