Riviera II
Print Q88   
IMO/VIN Callsign Flag Service Year
9333242 3EEK2 PANAMA Tank Ship 2006
Activity# Port Date Activity - Description Deficiencies
7613688 FPO, AP, Guam Jan 05, 23 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
AFTER ANY SURVEY OF THE SHIP HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE TO THE MACHINERY AND EQUIPMENT WITHOUT THE SANCTION OF THE ADMINISTRATION. MULTIPLE UNAPPROVED REPAIRS ON PORT AND STBD ANCHOR WASH PIPING WERE FOUND, WITH NO DOCUMENTATION FROM CLASS. 74 SOLAS (2020 ED.) I/11(B)Yes
Resolved DateResolution
Jan 06, 23Received survey for condition of Class. See Def documents.
6853390 Houston, Texas Nov 14, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 mm (.5 inch) diameter and is at least 25.4 mm (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern. Permanent studs at the fwd vapor line on the port side manifold and the aft vapor line on the starboard manifold were missing.Yes
Resolved DateResolution
Nov 21, 19Vessel provided pictures of repairs.
6594303 Honolulu, Hawaii Dec 17, 18 Vessel Inspection - Approved Inspection
6299587 Houston, Texas Nov 03, 17 Vessel Inspection - Approved Inspection
6040419 Houston, Texas Nov 15, 16 Vessel Inspection - Approved Inspection
5801052 BOSTON, Massachusetts Jan 21, 16 Vessel Transfer Monitor - Approved Inspection
5754014 STATEN ISLAND, New York Oct 30, 15 Vessel Inspection - Approved Inspection
5093832 Cape Canaveral, Florida Mar 31, 15 Vessel Inspection - Approved Inspection
5008558 Port Arthur, Texas Oct 23, 14 Vessel Inspection - Approved Inspection
4829824 STATEN ISLAND, New York Apr 05, 14 Vessel Inspection - Agency Action Complete
4800462 New Orleans, Louisiana Feb 16, 14 Vessel Operational Control - Agency Action Complete
4739231 Alameda, California Oct 22, 13 Enforcement - Payment Received
4729036 Seattle, Washington Oct 09, 13 Vessel Inspection - Approved Inspection
4718041 JBER, Alaska Sep 18, 13 Vessel Inspection - Forwarded
  1
SystemSubsystemCause
DocumentationSafety/Response Plans/ProgramsInvalid
DescriptionDue DateResolved
03 SEP 2013 the vessel YAYOI EXPRESS transited from Yeosu, Republic of Korea through the Western Alaska Captain of the Port Zone to Cherry Hill, WA without an approved Western Alaska Geographic-Specific Appendix in their Vessel Response Plan as required by 33 CFR 155.1030.Sep 18, 13Yes
Resolved DateResolution
Sep 18, 13The operating company has been issued a Notice of Violation.
4454904 San Francisco, California Oct 02, 12 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
1899-Tankers using inert gas system should maintain their cargo tanks in a non-flammable condition at all times. The following tanks were above 8% oxygen on 02OCT12 10:00 LT: 3S, 3P, 2S, 2P, 7S and 7P. Due to the hazard condition the certificate of compliance renewal exam was suspended until class verifies compliance.Oct 02, 12Yes
Resolved DateResolution
Oct 03, 12Received satisfactory NKK class survey report, dated 03OCT2012.
SystemSubsystemCause
DocumentationSafety Management System
DescriptionDue DateResolved
2500-The company should establish procedures for key shipboard operations concerning the safety of personnel, ship and protection of the environment. The vessel is not following their SMS operation-crude product manual section 5.2.2 that the oxygen levels is 5% or less and fill out form INSP. 002. The forms filled out on 01OCT12 shows oxygen levels at 5.3% or greater.Oct 02, 12Yes
Resolved DateResolution
Oct 03, 12Received satisfactory NKK class survey report, dated 03OCT2012.
3450516 San Pedro, California Apr 11, 09 Vessel Inspection - Agency Action Complete
3174907 San Pedro, California Mar 31, 08 Vessel Inspection - Agency Action Complete
2936103 San Francisco, California May 21, 07 Vessel Inspection - Approved Inspection
2916721 San Francisco, California Apr 27, 07 Boarding - Agency Action Complete
2915853 San Francisco, California Apr 26, 07 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
Accommodation/Occupational SafetyMedical/First Aid
DescriptionDue DateResolved
Controlled drugs were found in the refrigerator in the hospital space. The door to the refrigerator was not locked. According to the World Health Organization the recommendation is that the drugs (Atropine) should be kept refrigerated. The drugs were taken out and placed in the Captain’s safe until the ship's crew can place a hasp and lock on the door, ILO 147.Apr 27, 07Yes
Resolved DateResolution
Apr 27, 07The drugs were removed and a hasp and lock will be placed on the refrigerator door.
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
Mixed garbage was found in various parts of the vessel. Also the garbage plan did not address the disposal of medicines, batteries or containment of ash. All of these items were being kept on board and segregated but they have not been identified in their plan.Apr 27, 07Yes
Resolved DateResolution
Apr 27, 07Changes were being made to the plan to include the items listed. The plan will be sent off to the management company for approval.
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
The Ballast Water Management Plan is not ship specific. The plan is a mixture of items form the IMO Res. 868 (20), and incorporating items relating to the ship. But it doesn’t come close to being ship specific. Crew training is not being done, safety measures of when not to exchange ballast have not been addressed and the specific number of tanks or pumps are not listed.Yes
Resolved DateResolution
May 21, 07Received a copy of the ship''s specific BWM plan from the company superintendent.
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
The cargo and bunker transfer procedures were not in accordance with the Code of Federal Regulations.Apr 27, 07Yes
Resolved DateResolution
Apr 27, 07Copies of the regulations were given to the Master and Chief Officer. Changes were being made to the ship''s plan to include the items listed as per 33 CFR.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
The Sewage System is not being maintained as per the manufacturer's requirements. Weekly inspection are not being done.Apr 27, 07Yes
Resolved DateResolution
Apr 27, 07Changes were being made to the plan to include the items listed. The plan will be sent off to the management company for approval.
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel January 5,2023 January 5,2025 USCG
Certificate of Fitness - Chemical Carrier September 27,2018 February 27,2021 ABS
Classification Document August 16,2021 February 27,2026 ABS
COC-TVE Annual October 24,2014 October 24,2016 N/A
COC-TVE Renewal October 24,2014 October 24,2016 N/A
International Certificate of Fitness - Chemical August 16,2021 February 27,2026 ABS
International Load Line Certificate June 7,2022 February 27,2026 ABS
International Oil Pollution Prevention Certificate August 16,2021 February 27,2026 ABS
ISM - Document Of Compliance September 3,2020 September 9,2025 LR
ISM - Safety Management Certificate September 6,2018 July 17,2021 NKK
Minimum Safe Manning Document April 1,2020 PA
SOLAS Cargo Ship Safety Construction Certificate December 18,2015 February 27,2021 ABS
SOLAS Cargo Ship Safety Equipment Certificate August 16,2021 February 27,2026 ABS
SOLAS Cargo Ship Safety Radio Certificate May 26,2021 February 27,2026 ABS
Tonnage Certificate, International March 31,2021 ABS