IMO/VIN
Callsign
Flag
Service
Year
9264465
9V9680
SINGAPORE
Tank Ship
2002
Activity#
Port
Date
Activity - Description
Deficiencies
7369629
Wilmington, North Carolina
Jan 04, 22
Vessel Inspection - Approved Inspection
6938780
Savannah, Georgia
Apr 16, 20
Vessel Inspection - Approved Inspection
6938946
Savannah, Georgia
Apr 13, 20
Vessel Operational Control - Agency Action Complete
6915087
New Orleans, Louisiana
Feb 25, 20
Vessel Inspection - Administrative Action
6903394
Portsmouth, Virginia
Feb 08, 20
Vessel Inspection - Agency Action Complete
6666897
Houston, Texas
Apr 22, 19
Vessel Inspection - Approved Inspection
6666665
Houston, Texas
Apr 21, 19
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 14 - Pollution Prevention 141 - MARPOL Annex I Invalid
Description Due Date Resolved Contents of transfer procedures required by 33 CFR 155.750 must contain: (7) Procedures for topping off tanks. PSCOs attended vessel because the vessel was conducting bunker operations and during topping off 2S FO tank, approximately 125 gallons of FO spilled on deck and 40 gallons discharged into US waters. PSCOs requested topping off procedures from the CE. CE presented procedures that do not specify crew member responsibilities/roles/procedures after 90% volume is surpassed. Vessel is prohibited from conducting bunker operations until transfer procedures for topping off are provided.
33 CFR 155.750(a)(7) Yes
Resolved Date Resolution Apr 22, 19 Recieved bunkering procedure and e-mail corespondence from master stating procedures for bunkering contained all pertenant information.
6667473
WASHINGTON, District of Columbia
Apr 20, 19
Incident Investigation - Agency Action Complete
6543326
STATEN ISLAND, New York
Sep 19, 18
Vessel Inspection - Approved Inspection
5102326
New Orleans, Louisiana
Apr 13, 15
Vessel Operational Control - Agency Action Complete
4940835
Brownsville, Texas
Aug 18, 14
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Fire Fighting Firemans Outfit
Description Due Date Resolved Ships shall carry at least two firefighting outfits. In addition, on tankers, two additional firefighting outfits shall be provided. Vessel is missing two out of four pair of pants, resulting in two of the required suits being incomplete. Aug 22, 14 Yes
Resolved Date Resolution Aug 19, 14 vessel provided proof of purchasing/obtaining 4 new and complete firefighting outfits IAW applicable requirements.
4284016
Baltimore, Maryland
Apr 10, 12
Vessel Inspection - Agency Action Complete
4011115
Baltimore, Maryland
May 14, 11
Vessel Inspection - Approved Inspection
3769672
ST PETERSBURG, Florida
Jun 18, 10
Vessel Inspection - Approved Inspection
3769672
Tampa, Florida
Jun 18, 10
Vessel Inspection - Approved Inspection
3713240
ST PETERSBURG, Florida
Apr 10, 10
Vessel Inspection - Approved Inspection
3713240
Tampa, Florida
Apr 10, 10
Vessel Inspection - Approved Inspection
3570430
STATEN ISLAND, New York
Aug 19, 09
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Engineering Fuel Oil Storage/Transfer System Improper/Lack of Maintenance
Description Due Date Resolved During inspection, found the D/O transfer bunkering manifold deck isolation valves wasted. Handle locking devices were inoperative and tied closed with polypro line. repair replace valve handles with new to the satisfaction of class surveyor. Solas (04) CH I/ reg11 Yes
Resolved Date Resolution Apr 16, 10 Received survey for the locking device.
System Subsystem Cause Fire Fighting Firemans Outfit
Description Due Date Resolved Two of four FF suits are worn and in need of replacement. To satisfaction of class society. Sep 19, 09 Yes
Resolved Date Resolution Aug 19, 09 Received purchase receipt that 2 FF suits were purchased.
3566823
STATEN ISLAND, New York
Aug 19, 09
Boarding - Agency Action Complete
3570369
STATEN ISLAND, New York
Aug 19, 09
Vessel Inspection - Approved Inspection
2266116
San Francisco, California
Dec 29, 04
Vessel Inspection - Approved Inspection
2195132
San Francisco, California
Sep 13, 04
Vessel Inspection - Approved Inspection
3
0
System Subsystem Cause Lifesaving Launching Appliances Improper/Lack of Maintenance
Description Due Date Resolved During the lifeboat drill one of the wire cables parted on the port lifeboat quick release. The crew as directed to replace the cable. Oct 14, 04 Yes
Resolved Date Resolution Dec 20, 04 Received documentation from vessel, via fax, attesting to renewal of the port lifeboat quick release wire.
System Subsystem Cause Electrical Electrical Distribution System (service) Unknown
Description Due Date Resolved The rubber matting around all the electrical panels throughout the vessel is inadequate. It does not meet the requirements of SOLAS 2001 II-1 Reg 40, 45-1.3 or 45-2. Required the company to look into this and supply rubber matting for the protection of all personnel that come into contact with any electrial panel 440V and over. Oct 14, 04 Yes
Resolved Date Resolution Dec 20, 04 Rubber matting received and placed onboard.
System Subsystem Cause Pollution Prevention/Response Prevention Equipment Improper/Lack of Maintenance
Description Due Date Resolved The Sewage Treatment plant has not been properly maintained or serviced by the crew. They only add tablets when entering a US ports. Required the crew to start maintaining and servicing the system as required by the manufacturer. Oct 14, 04 Yes
Resolved Date Resolution Dec 20, 04 Received documentation via fax from vessel attesting to training of crew on the use of the Sewage Treatment Plant and proper maintainance of the Sewage Treatment Plant via Sewage log book.
1776251
CORPUS CHRISTI, Texas
Apr 18, 03
Vessel Inspection - Agency Action Complete
1774387
CORPUS CHRISTI, Texas
Apr 18, 03
Vessel Inspection - Agency Action Complete
Documents
Issued
Expires
Agency
Certificate of Compliance - Chemical Carrier
April 18,2003
April 18,2005
N/A
Certificate of Compliance - Tank Vessel
May 14,2011
May 14,2012
USCG
Certificate of Fitness - Chemical Carrier
October 23,2017
September 9,2022
NKK
Classification Document
April 14,2019
September 9,2022
NKK
International Certificate of Fitness - Chemical
May 9,2014
September 9,2017
NKK
International Load Line Certificate
October 23,2017
September 9,2022
NKK
International Oil Pollution Prevention Certificate
April 14,2019
September 9,2022
NKK
ISM - Document Of Compliance
September 3,2021
September 16,2026
NKK
ISM - Safety Management Certificate
December 29,2016
November 17,2021
ABS
Minimum Safe Manning Document
August 28,2014
SG
SOLAS Cargo Ship Safety Construction Certificate
April 14,2019
September 9,2022
NKK
SOLAS Cargo Ship Safety Equipment Certificate
April 14,2019
September 9,2022
NKK
SOLAS Cargo Ship Safety Radio Certificate
October 23,2017
September 9,2022
NKK
Tonnage Certificate, International
November 22,2011
NKK