Torm Ragnhild
Print Q88   
IMO/VIN Callsign Flag Service Year
9290579 9V3905 DENMARK Tank Ship 2005
Activity# Port Date Activity - Description Deficiencies
7412125 San Pedro, California Mar 15, 22 Vessel Inspection - Approved Inspection
7188546 Houston, Texas May 04, 21 Vessel Operational Control - Approved Inspection
7143052 STATEN ISLAND, New York Feb 19, 21 Vessel Inspection - Approved Inspection
6925906 STATEN ISLAND, New York Mar 13, 20 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemDamaged By Earlier Event
DescriptionDue DateResolved
Tankers fitted with an inert gas system shall be provided with a closed ullage system. The ullage sensor on the no. 3 starboard cargo tank is inoperable and shows an inaccurate reading. Must be repaired prior to loading cargo. cite: 74 SOLAS (14) II-2/4.5.5.3Mar 13, 20Yes
Resolved DateResolution
Feb 20, 21
6925402 STATEN ISLAND, New York Mar 12, 20 Boarding - Agency Action Complete
6922443 STATEN ISLAND, New York Mar 08, 20 Vessel Operational Control - Agency Action Complete
6628811 Houston, Texas Feb 25, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Parties responsible for fir extinguishing shall be organized. These parties shall have the capacity to complete their duties at all times while the ship is in service (15.2.1.3). Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire fighting systems and appliances that they may be called upon to use (15.2.2.1). PSCO observed crewman improperly donning SCBA mask, allowing air to escape due to improper seal of mask. Crewman then approached fire engaged in fire fighting efforts with no air pressure left in bottle. Additionally, crew attempted to fight simulated oil fire on cargo deck with fire hose connected to fire hydrant instead of foam applicator to foam line. 74 SOLAS (14) II-2/15.2Feb 25, 19Yes
Resolved DateResolution
Feb 25, 19PSCO subsequently observed second fire drill to the satisfaction of the PSCO.
6362539 San Francisco, California Feb 27, 18 Vessel Inspection - Approved Inspection
6348069 San Francisco, California Feb 03, 18 Vessel Inspection - Approved Inspection
  9
SystemSubsystemCause
Fire FightingStructural - A Class DivisionsImproper Installation
DescriptionDue DateResolved
A grinding workshop was found within the air conditioning room which is not classified as a high risk service space. (74 SOLAS II-2/9.2.4.2.2.2(9)Feb 03, 18Yes
Resolved DateResolution
Feb 03, 18Crew removed grinder from space.
SystemSubsystemCause
ElectricalElectric Generation Source (service)Improper Installation
DescriptionDue DateResolved
Grounding wire for the fuel oil supply pump number one was found unattached within the purifier room. Wiring for the number two supply pump within the purifier room found frayed.(74 SOLAS II-1/45.5.5)Feb 03, 18Yes
Resolved DateResolution
Feb 03, 18Crew attached grounding wire and replaced frayed wire.
SystemSubsystemCause
Deck/CargoInert Gas SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Main supply pump to deck water seal was found to be corroded and leaking where supply line exits engine room. (74 SOLAS II-2/4.5.5.3.2) Prior to conducting cargo.Feb 03, 18Yes
Resolved DateResolution
Feb 05, 18Crew inspected corroded flange area and found the gasket wasted. Gasket replaced.
SystemSubsystemCause
Accommodation/Occupational SafetyVentilationImproper Installation
DescriptionDue DateResolved
Modified ventilation ducting is installed on lube oil pump and compressor control unit in engine room. (74 SOLAS II-1/35)Mar 03, 18Yes
Resolved DateResolution
Feb 27, 18Received class report attesting to removal of temporary ducting.
SystemSubsystemCause
Deck/CargoInert Gas SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Multiple areas of corrosion and leaking were found on the inert gas cooling line and inert gas cooling drain line. (74 SOLAS II-2/4.5.5.3.2). Prior to conducting cargo.Feb 03, 18Yes
Resolved DateResolution
Feb 05, 18Crew replaced leaking portions of pipe.
SystemSubsystemCause
EngineeringSteam System (auxiliary)Improper/Lack of Maintenance
DescriptionDue DateResolved
Scupper line on boiler deck outside containment found leaking. (74 SOLAS I-11)Mar 03, 18Yes
Resolved DateResolution
Feb 05, 18Crew replaced pipe.
SystemSubsystemCause
Deck/CargoHolds/TanksImproper/Lack of Maintenance
DescriptionDue DateResolved
The gas sampling main pump for the void and ballast spaces was found to be inoperable. (74 SOLAS II-2/4.5.7.2.2)Feb 03, 18Yes
Resolved DateResolution
Feb 03, 18Crew repaired and brought pump back into service.
SystemSubsystemCause
Deck/CargoHolds/TanksImproper/Lack of Maintenance
DescriptionDue DateResolved
The infrared sensor for the gas detection equipment was found out of calibration and requires manufacturer servicing per the manufacturers manual. (74 SOLAS II-2/4.5.7.2.2)Mar 03, 18Yes
Resolved DateResolution
Feb 27, 18Received class report attesting to proper servicing/calibration.
SystemSubsystemCause
Construction/LoadlineStructuresImproper/Lack of Maintenance
DescriptionDue DateResolved
Wasted metal door frame leading into engine room funnel from port side ventilation. (74 SOLAS I-11)Mar 03, 18Yes
Resolved DateResolution
Feb 27, 18Received class report attesting to proper repairs.
6286811 New Orleans, Louisiana Oct 13, 17 Vessel Inspection - Agency Action Complete
6169566 Lewes, Delaware Jun 12, 17 Vessel Inspection - Approved Inspection
6170857 PHILADELPHIA, Pennsylvania Jun 10, 17 Vessel Operational Control - Agency Action Complete
6127567 WASHINGTON, District of Columbia Jan 18, 17 Incident Investigation - Agency Action Complete
6069246 Savannah, Georgia Jan 11, 17 Vessel Inspection - Approved Inspection
5236397 New Orleans, Louisiana Sep 06, 15 Vessel Inspection - Approved Inspection
5147441 Lewes, Delaware Jun 08, 15 Vessel Inspection - Approved Inspection
4915734 Seattle, Washington Jun 30, 14 Vessel Inspection - Approved Inspection
4869880 San Pedro, California May 28, 14 Vessel Inspection - Approved Inspection
4736650 Miami Beach, Florida Oct 18, 13 Vessel Inspection - Agency Action Complete
4266766 Brownsville, Texas Mar 19, 12 Vessel Inspection - Approved Inspection
2867980 Houston, Texas Feb 06, 07 Vessel Inspection - Agency Action Complete
2734435 Honolulu, Hawaii Aug 02, 06 Vessel Inspection - Agency Action Complete
2532407 STATEN ISLAND, New York Nov 10, 05 Vessel Operational Control - Agency Action Complete
2528787 STATEN ISLAND, New York Nov 05, 05 Boarding - Agency Action Complete
2528776 STATEN ISLAND, New York Nov 05, 05 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Deck covering in the engine control room has lifted and buckeled which poses a high risk of tripping. Make the decking flat so not to pose a tripping hazard. Repair by 05Dec05 to the satisfaction of the Administration.Dec 05, 05Yes
Resolved DateResolution
Aug 02, 06The deck covering in the engine control room has now been renewed and found satisfactory in accordance with the vessel''s classification society.
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel October 18,2013 October 18,2015 N/A
Certificate of Fitness - Chemical Carrier October 19,2012 October 26,2015 N/A
Classification Document May 9,2015 April 26,2020 LR
COC-TVE Renewal February 19,2021 February 19,2023 N/A
International Load Line Certificate December 10,2020 April 26,2025 LR
International Oil Pollution Prevention Certificate March 4,2017 March 3,2022 LR
ISM - Document Of Compliance April 20,2018 May 1,2023 LR
ISM - Safety Management Certificate May 31,2014 September 7,2015 LR
Minimum Safe Manning Document February 13,2019 SG
SOLAS Cargo Ship Safety Construction Certificate December 10,2020 April 26,2025 LR
SOLAS Cargo Ship Safety Equipment Certificate December 10,2020 April 26,2025 LR
SOLAS Cargo Ship Safety Radio Certificate November 20,2018 April 26,2020 LR
Tonnage Certificate, International April 27,2005 April 26,2010 LR