Maersk Peary
Print Q88   
IMO/VIN Callsign Flag Service Year
1235135 WHKM UNITED STATES Tank Ship
Activity# Port Date Activity - Description Deficiencies
7371534 APO, AE, Dec 21, 21 Vessel Inspection - Agency Action Complete
7325974 APO, AE, Oct 04, 21 Vessel Inspection - Approved Inspection
7307998 APO, AE, Sep 09, 21 Vessel Inspection - Agency Action Complete
7277594 APO, AE, Aug 05, 21 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
01 - Certificates & Documentation011 - Ships Certificates
DescriptionDue DateResolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. The station license on board the vessel was expired. 47 CFR 80.13(a) COMSAR/Circ.32 1.7.1-.2Yes
Resolved DateResolution
Aug 27, 21Verified FCC station license was on board and the call sign remained the same.
SystemSubsystemCause
15 - Safety Management Systems (ISM)N/A - No Subsystem
DescriptionDue DateResolved
The company should ensure that each ship is appropriately manned in order to encompass all aspects of maintaining safe operations on board. The ship did not have a procedure on board to account for documenting STCW Work/Rest hours while the vessel was operating in the Periodically Unattended Machinery Space condition. SOLAS (2009 Cons) XI-1/5 ISM Code Part A 6.2.2Sep 27, 21Yes
Resolved DateResolution
Nov 10, 21Provided satisfactory ISM audit report capturing CG-835. See documents tab for report.
SystemSubsystemCause
15 - Safety Management Systems (ISM)N/A - No Subsystem
DescriptionDue DateResolved
The company should ensure that valid documents are available at all relevant locations and obsolete documents are properly removed. The station license was expired. Outdated/expired ship certificates, records, and security records were identified.Sep 27, 21Yes
Resolved DateResolution
Nov 10, 21Provided satisfactory ISM audit report capturing CG-835. See documents tab for report.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
The high-level alarm system shall be independent of the overflow-control system. A tank overflow-control system required by this section shall come into operation when the normal tank loading procedures fail to stop the tank liquid level exceeding the normal full condition. The high level alarm and overflow-control alarm in cargo tank 5 port were activating opposite to the regulation.Aug 27, 21Yes
Resolved DateResolution
Aug 27, 21The ship's crew adjusted the alarms to function properly.
SystemSubsystemCause
01 - Certificates & Documentation013 - Documents
DescriptionDue DateResolved
When a seafarer is on call, such as when a machinery space is unattended, the seafarer shall have an adequate compensatory rest period if the normal period of rest is disturbed by call-outs to work. During Periodically Unattended Machinery Space (PUMS) operations, the officer(s) in charge of engineering watches are not tracking night alarms in Watchkeeper, the program the ship uses to account for STCW Work/Rest hours. STCW (2020) Part A-VIII/1.6 CG-CVC Policy Letter 12-05Sep 27, 21Yes
Resolved DateResolution
Sep 24, 21Received documentation from vessel satisfying CG-835.
7237821 APO, AE, Jun 28, 21 Vessel Inspection - Agency Action Complete
7090061 APO, AE, Nov 17, 20 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. An SCBA harness had a broken harness clip logged in a maintenance log go unaddressed for an excess of 6 months. SOLAS (04)/II-2 14.2.2.1Nov 18, 20Yes
Resolved DateResolution
Nov 18, 20Vessel master produced a procurement receipt for harness clip.
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Measures shall be taken to the satisfaction of the administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. ECR engine room bilge remote operation was not operating properly. SOLAS (04)/II-1 46.2Nov 18, 20Yes
Resolved DateResolution
Nov 18, 20Remote operation was tested incorrectly. CHENG properly demonstrated operation of remote valve open and close.
SystemSubsystemCause
01 - Certificates & Documentation013 - DocumentsDesign Flaw
DescriptionDue DateResolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Update Fire and Safety plan to include Polar Code Code equipment. SOLAS (14)/I 11(a)Dec 19, 20Yes
Resolved DateResolution
Jan 27, 21ABS issued Finding 1256 on 27Jan2021.
6947752 WASHINGTON, District of Columbia May 03, 20 Incident Investigation - Agency Action Complete
6783090 APO, AE, Aug 14, 19 Vessel Inspection - Approved Inspection
  6
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
. Lifebuoy near port side inflatable liferafts is not properly markedOct 07, 19Yes
Resolved DateResolution
Sep 07, 19Lifering properly marked and verified
SystemSubsystemCause
08 - AlarmsN/A - No SubsystemImproper Installation
DescriptionDue DateResolved
Composite boiler panel had jury rigged alarm boxes, repair/replace alarm boxes and remove zip ties holding panels in place.Oct 07, 19Yes
Resolved DateResolution
Sep 07, 19Crew located and replaced proper brackest which vibrated loose.
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Electrical cable to composite boiler quick closing valve controller found missing bushing/connector to box, allowing connection to act as securing point of cable.Oct 07, 19Yes
Resolved DateResolution
Sep 07, 19Crew provided bushing/connector to junction box to support cable weight in the box.
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No SubsystemDesign Flaw
DescriptionDue DateResolved
HFO-MGO fuel solenoids found with zip ties holding them together, repair/replace parts to proper working order.Oct 07, 19Yes
Resolved DateResolution
Sep 09, 19Vessel procured 6 new solenoids and has replaced broken fittings.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The vessel’s inventory of required sampling equipment is not being stored at the required temperature making it invalidOct 07, 19Yes
Resolved DateResolution
Sep 09, 19Vessel procured a new, dedicated refrigerator for colormetric tube storage, as required by mftr.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The vessel’s stbd manifold vapor connection is improperly paintedSep 13, 19Yes
Resolved DateResolution
Sep 07, 19Vapor line was repainted with correct color/spacing
6677929 APO, AE, May 06, 19 Vessel Inspection - Approved Inspection
6637855 APO, AE, Mar 07, 19 Vessel Inspection - Approved Inspection
6534703 APO, AE, Sep 24, 18 Vessel Inspection - Approved Inspection
6522971 APO, AE, Sep 06, 18 Vessel Inspection - Approved Inspection
6469025 APO, AE, Jul 03, 18 Vessel Inspection - Approved Inspection
6445035 APO, AE, Jun 09, 18 Vessel Inspection - Agency Action Complete
6346735 WASHINGTON, District of Columbia Dec 26, 17 Incident Investigation - Agency Action Complete
6289948 APO, AE, Nov 14, 17 Vessel Inspection - Approved Inspection
6304307 WASHINGTON, District of Columbia Nov 10, 17 Vessel Inspection - Approved Inspection
6245747 APO, AE, Aug 20, 17 Vessel Inspection - Administrative Action
6228048 APO, AE, Aug 02, 17 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringSteering Gear System
DescriptionDue DateResolved
Replace No. 2 steering gear motor.Aug 02, 17Yes
Resolved DateResolution
Sep 01, 17ABS witnessed repairs.
6175409 APO, AE, Jun 14, 17 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
NavigationCollision/Grounding AvoidanceDesign Flaw
DescriptionDue DateResolved
Vessel submitted a CG-2692 for inoperable S Band Radar . 33CFR164.26(b), 74SOLAS V/19.2.7.1Jun 17, 17Yes
Resolved DateResolution
Jun 14, 1714JUN17, 14:36 Received technician report and repairs have been made to a faulty power supply.
6063033 APO, AE, Dec 28, 16 Vessel Inspection - Agency Action Complete
5965658 APO, AE, Aug 08, 16 Vessel Inspection - Approved Inspection
5858219 APO, AE, Apr 20, 16 Vessel Inspection - Approved Inspection
5828683 Portsmouth, Virginia Mar 08, 16 Vessel Inspection - Approved Inspection
5204407 FPO, AP, Aug 23, 15 Vessel Inspection - Approved Inspection
5144598 APO AP, Jun 05, 15 Vessel Inspection - Approved Inspection
5019310 FPO, AP, Nov 07, 14 Vessel Inspection - Approved Inspection
4985267 FPO, AP, Guam Sep 17, 14 Vessel Inspection - Administrative Action
4994437 APO AP, Sep 09, 14 Vessel Inspection - Approved Inspection
4975823 Honolulu, Hawaii Sep 05, 14 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
LifesavingLifeboat
DescriptionDue DateResolved
Provide serviceable air bottles for free-fall lifeboat prior to carrying cargo. Prove proper outfitting of free-fall lifeboat to the satisfaction of attending Coast Guard Marine Inspector.Yes
Resolved DateResolution
Sep 27, 14Received ABS Class report confirming proper outfitting of 3 serviceable air bottles for their free fall lifeboat. See Class report in Certs/Documentation for additional details.
4978018 WASHINGTON, District of Columbia Sep 05, 14 Incident Investigation - Agency Action Complete
4962789 APO AP, Sep 02, 14 Vessel Inspection - Approved Inspection
4896483 FPO, AP, Guam Jun 23, 14 Vessel Inspection - Agency Action Complete
4854353 Portsmouth, Virginia May 09, 14 Vessel Inspection - Approved Inspection
4826677 APO AP, Apr 01, 14 Vessel Inspection - Approved Inspection
4730836 Seattle, Washington Oct 07, 13 Enforcement - Agency Action Complete
4739676 Portsmouth, Virginia Sep 29, 13 Vessel Inspection - Approved Inspection
4705190 FPO, AP, Guam Sep 03, 13 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)Improper/Lack of Maintenance
DescriptionDue DateResolved
Demonstrate proper operation of the F/O guage on the local panel for thw #2 DGOct 04, 13Yes
Resolved DateResolution
Sep 25, 13Demonstrated proper operation of the F/O guage on the local panel for thw #2 DG
SystemSubsystemCause
EngineeringCompressed Air System (start air)
DescriptionDue DateResolved
Demonstrate proper operation of the relief valves for start air & deck service UPVs in the engine room or provide bench tests results for the same.Nov 04, 13Yes
Resolved DateResolution
Sep 25, 13Demonstrated proper operation of the relief valves for start air & deck service UPVs in the engine room or provide bench tests results for the same.
SystemSubsystemCause
Operations/ManagementDrug and Alcohol Testing
DescriptionDue DateResolved
Provide alcohol testing devices.Oct 04, 13Yes
Resolved DateResolution
Sep 19, 13ALCOSENSOR calibration gas provided.
SystemSubsystemCause
LifesavingRescue Boat Equipment
DescriptionDue DateResolved
Provide second paddle for rescue boat.Oct 04, 13Yes
Resolved DateResolution
Sep 05, 13Paddles provided.
SystemSubsystemCause
Construction/LoadlineStructuresImproper/Lack of Maintenance
DescriptionDue DateResolved
Replace FSD between steering space and engine room.Oct 04, 13Yes
Resolved DateResolution
Sep 19, 13FSD replaced.
4706562 WASHINGTON, District of Columbia Aug 19, 13 Incident Investigation - Agency Action Complete
4474831 FPO, AP, Oct 30, 12 Vessel Inspection - Approved Inspection
4396555 APO, AE, Sep 05, 12 Vessel Inspection - Approved Inspection
4337361 WASHINGTON, District of Columbia Jun 05, 12 Incident Investigation - Agency Action Complete
4333200 WASHINGTON, District of Columbia May 24, 12 Incident Investigation - Agency Action Complete
4199036 APO, AE, Dec 01, 11 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Operations/ManagementVessel Safety Management
DescriptionDue DateResolved
In reference to Vital Systems Automation Periodic Safety Test Procedures, Revision 1.5, dated October 24,2011: conduct procedures not accomplished during CG attendance, note corrections and submit necessary amendments (including those found during CG testing) to USCG MSC for review.Jun 11, 12Yes
Resolved DateResolution
Sep 05, 12verified latest revision of PSTP, all sat
4162609 WASHINGTON, District of Columbia Oct 06, 11 Vessel Inspection - Agency Action Complete
4163485 WASHINGTON, District of Columbia Oct 03, 11 Incident Investigation - Agency Action Complete
4133137 Portsmouth, Virginia Sep 01, 11 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
Repair and prove proper operation of the navigation light display and alarm panel IAW COLREGS.Nov 28, 11Yes
Resolved DateResolution
Sep 05, 12
SystemSubsystemCause
Accommodation/Occupational SafetyCooking Systems
DescriptionDue DateResolved
Vessel operator shall provide adequate cooking facilities sufficient in size for the crew and its intended voyage IAW ILO 147, Food and Catering (Ships' Crews) Convention, 1946 (No. 68) (Article 5) prior to sailing. Sep 28, 11Yes
Resolved DateResolution
Sep 30, 11Received e-mail confirmation from vessel Master that new galley stove and fryer were installed an operational. Cleared CG-835 based on Master''s confirmation.
SystemSubsystemCause
ElectricalLighting (service)
DescriptionDue DateResolved
Vessel shall complete installation of main deck perimeter security lighting, which is required per the ships approved security plan, and provide evidence that light fixtures meet requirements for installation in a hazardous location IAW 33 CFR 104.400 and SOLAS Ch.II-1, Reg 45.Nov 28, 11Yes
Resolved DateResolution
Oct 19, 11Received ABS class report attesting to the installation of security lighting and verification of its use in hazardous locations - requirement cleared based upon ABS report.
2672496 STATEN ISLAND, New York Jun 06, 06 Boarding - Agency Action Complete
2613925 San Pedro, California Mar 31, 06 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
Unable to verify calibration of IGS Oxygen sensor due to span gas bottle accuracy. Unable to verify calibration and accuracy of span gas bottle. Replace/calibrate span gas bottle for IGS Oxygen sensor to the satisfaction of the USCG. Oxygen level in tanks were below 5%. SOLAS 74 amended CH II-2 Reg 62Apr 03, 06Yes
Resolved DateResolution
Apr 05, 06Received faxed analysis report stating analysis is complete.
2609664 San Pedro, California Mar 26, 06 Vessel Operational Control - Agency Action Complete
2505146 DANIA, Florida Sep 30, 05 Boarding - Agency Action Complete
2504804 DANIA, Florida Sep 29, 05 Boarding - Agency Action Complete
2501815 Miami Beach, Florida Sep 26, 05 Vessel Operational Control - Agency Action Complete
2324635 JBER, Alaska Mar 31, 05 Boarding - Agency Action Complete
2350450 JBER, Alaska Mar 30, 05 Vessel Inspection - Approved Inspection
2314323 San Pedro, California Mar 19, 05 Vessel Inspection - Approved Inspection
2314008 San Pedro, California Mar 19, 05 Boarding - Agency Action Complete
2310156 San Pedro, California Mar 14, 05 Vessel Operational Control - Agency Action Complete
2613028 San Pedro, California Feb 01, 01 Boarding - Agency Action Complete
Documents Issued Expires Agency
CERTIFICATE OF DOCUMENTATION April 5,2022 March 31,2023 USCG
Certificate of Fitness - Chemical Carrier September 28,2016 September 20,2021 ABS
Certificate of Inspection August 18,2016 September 28,2021 USCG
Certificate of Inspection - Amended August 18,2016 September 28,2021 USCG
Classification Document September 21,2011 September 20,2016 ABS
International Certificate of Fitness - Chemical November 7,2013 September 20,2016 ABS
International Load Line Certificate November 11,2014 September 20,2016 ABS
International Oil Pollution Prevention Certificate September 28,2016 September 20,2021 ABS
ISM - Document Of Compliance January 11,2017 September 4,2018 ABS
ISM - Safety Management Certificate May 29,2005 May 8,2010 N/A
SOLAS Cargo Ship Safety Construction Certificate September 28,2016 September 20,2021 ABS
SOLAS Cargo Ship Safety Equipment Certificate September 28,2016 September 20,2021 ABS
SOLAS Cargo Ship Safety Radio Certificate September 26,2011 September 28,2012 N/A
Tonnage Certificate, International September 8,2011 ABS