9269257 9V2885 SINGAPORE Tank Ship 2003
Activity# Port Date Activity - Description Deficiencies
7429738 Cape Canaveral, Florida Apr 12, 22 Vessel Inspection - Agency Action Complete
7394306 Cape Canaveral, Florida Feb 16, 22 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
07126-Fire Safety-Means shall be provided to control leaks of flammable liquids. PSCO noticed excess fuel oil on SSDG #1 & #2 coming #7 cylinder & by fuel pumps. 74 SOLAS (14) II-2/4.1.1Mar 02, 22Yes
Resolved DateResolution
Feb 17, 22Lloyds provided documentation and proof of corrective actions that were up to USCG standards. Deficiency cleared.
SystemSubsystemCause
09 - Working and Living Conditions092 - Working Conditions
DescriptionDue DateResolved
09219-Working Conditions-Surfaces with temperatures of 220 C which may be impinged as a result of fuel system failure shall be properly insolated. PSCO noticed lagging missing from #3 SSDG exhaust manifold. 74 SOLAS (14) II-2/4.2.2.6.1Mar 16, 22Yes
Resolved DateResolution
Apr 12, 22
7394251 Cape Canaveral, Florida Feb 10, 22 Vessel Inspection - Agency Action Complete
6145755 STATEN ISLAND, New York May 14, 17 Vessel Inspection - Approved Inspection
  20
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
1" stud is missing from the vapor flange.Jul 19, 17Yes
Resolved DateResolution
May 19, 17
SystemSubsystemCause
Fire FightingPortable Dry Chemical Fire Extinguisher
DescriptionDue DateResolved
All Portable and semi portable extinguishers had defective, missing, or broken brackets and securing arrangments.Jul 19, 17Yes
Resolved DateResolution
Feb 10, 22
SystemSubsystemCause
ElectricalLighting (emergency)
DescriptionDue DateResolved
Emergency Lighting fixture above the emergency generator room panel is inoperable.May 28, 17Yes
Resolved DateResolution
May 19, 17Received Class report attesting to the proper operation of the emergency lighting fixture in the emergency generator room.
SystemSubsystemCause
EngineeringEngine Controls (Electric/Electronic)
DescriptionDue DateResolved
Engine Room Alarm system is currently provided with power from the main ships supply due to a faulty converter. Ship to provide documentation from the technician identifying the propblem and class documentation attesting an adequate repair proposal.Jul 19, 17Yes
Resolved DateResolution
Feb 10, 22
SystemSubsystemCause
Fire FightingFire Hoses
DescriptionDue DateResolved
Fire hoses in Engine Room are wasted and worn.May 28, 17Yes
Resolved DateResolution
May 19, 17Received Class report attesting to the renewal of all fire hoses within the engine room space.
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
Garbage record book was found with 4 pages not signed and certified by the captain.May 19, 17Yes
Resolved DateResolution
May 19, 17Deficiency corrected on the spot.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
High level and overfill alarms are stencilled red. Re-mark the visual communications in black lettering.Yes
Resolved DateResolution
May 19, 17Received Class report attesting to the proper marking.
SystemSubsystemCause
EngineeringSteering Gear System
DescriptionDue DateResolved
Hydraulic leaks identified at all hard line connections in the steering gear system.Jul 19, 17Yes
Resolved DateResolution
Feb 10, 22
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
IGG/IGS manual not updated to reflect the generator being decommissioned in 2014.May 19, 17Yes
Resolved DateResolution
May 19, 17Class endorsed the IGS/IGG manual as approved prior to completion of USCG examination.
SystemSubsystemCause
EngineeringFreshwater System (jacketwater cooling)
DescriptionDue DateResolved
Main engine has jacket water leak on #5 cylinder. Class added #2 cylinder leaking the same.Jul 19, 17Yes
Resolved DateResolution
Feb 10, 22
SystemSubsystemCause
EngineeringFreshwater System (jacketwater cooling)
DescriptionDue DateResolved
Main engine sea water cooling pump has a failing mechanical seal.Jul 19, 17Yes
Resolved DateResolution
Feb 10, 22
SystemSubsystemCause
Accommodation/Occupational SafetyWashroom/Toilet
DescriptionDue DateResolved
Public water closet on deck C drains onto the floor. 33 USC 1221(b)Yes
Resolved DateResolution
May 19, 17Received class report attesting to proper repairs of the wash basin.
SystemSubsystemCause
Operations/ManagementVessel Safety Management
DescriptionDue DateResolved
Recommend internal audit be submitted to the Coast Guard.May 28, 17Yes
Resolved DateResolution
Feb 10, 22
SystemSubsystemCause
Accommodation/Occupational SafetyVentilation
DescriptionDue DateResolved
SPace ventilation in the Bosun's store is inoperable.Jul 19, 17Yes
Resolved DateResolution
Feb 10, 22
SystemSubsystemCause
CommunicationsAlarms/Indicators
DescriptionDue DateResolved
Steering Gear local rudder angle indicator displays readings 10 degress error.Jul 19, 17Yes
Resolved DateResolution
Feb 10, 22
SystemSubsystemCause
EngineeringShafting/Propeller Arrangements
DescriptionDue DateResolved
Upper Bearing of Ships Shaft log is leaking oil.Yes
Resolved DateResolution
May 19, 17Long term engineering condition issued to be rectified at the vessel next dry-dock. Additional monitoring procedures implemented to the satisfaction of class.
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
VCS flange was not properly painted Red/yellow/Red.Yes
Resolved DateResolution
May 19, 17Deficiency corrected on the spot.
SystemSubsystemCause
ElectricalElectric Supply System (service)
DescriptionDue DateResolved
Vent fan for the paint locker has exposed bare wire requiring renewal.Yes
Resolved DateResolution
May 19, 17Class report received attesting to the proper repairs of the exposed wiring.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Weld has been tripped on the guard rail in way of the main engine.Yes
Resolved DateResolution
May 19, 17Received class report attesting to renewal of the tripped weld identified.
SystemSubsystemCause
Operations/ManagementVessel Safety Management
DescriptionDue DateResolved
Written procedure could not be provided to identify the specifc steps to properly demonstrate the required IGS system shutdowns and associated alarms.May 19, 17Yes
Resolved DateResolution
May 19, 17Received Class report. Written procesdures now provided for the ships crew regarding proper procedures for the IGS system.
5214482 ST PETERSBURG, Florida Aug 12, 15 Vessel Transfer Monitor - Agency Action Complete
5214482 Tampa, Florida Aug 12, 15 Vessel Transfer Monitor - Agency Action Complete
5179218 San Pedro, California Jul 09, 15 Vessel Inspection - Approved Inspection
4987482 San Pedro, California Sep 28, 14 Vessel Inspection - Approved Inspection
4854498 San Pedro, California May 09, 14 Vessel Inspection - Approved Inspection
4558273 FPO, AP, Guam Mar 30, 13 Vessel Inspection - Approved Inspection
4009123 Woods Hole, Massachusetts May 15, 11 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
Accommodation/Occupational SafetyVentilation
DescriptionDue DateResolved
Installed power ventilation in forepeak is inoperable. Crew must effect repairs to the satisfaction of class.May 22, 11Yes
Resolved DateResolution
May 20, 11Received BV Class report stating that fan has been replaced and tested sat.
SystemSubsystemCause
Operations/ManagementVessel Safety Management
DescriptionDue DateResolved
Oily water separator, incinerator, voyage data recorder, and B.A. Compressor have been given dispensation by the administration for their inoperability. Documenting, reporting, and tracking of these occurrences are inconsistent with in place SMS filing procedures.Jun 14, 11Yes
Resolved DateResolution
May 20, 11Received BV Class report stating issue has been reviewed and addressed.
3632015 Mobile, Alabama Nov 13, 09 Vessel Inspection - Approved Inspection
3463162 STATEN ISLAND, New York Apr 28, 09 Boarding - Agency Action Complete
3425851 San Pedro, California Mar 01, 09 Vessel Operational Control - Agency Action Complete
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
Vessel became aware of malfunctioning 3-CM radar upon inbound transit to El Segundo Lightering Area.Yes
Resolved DateResolution
Mar 04, 09Rec''d tech report, all sat
3358418 Houston, Texas Nov 06, 08 Boarding - Approved Inspection
3356740 TEXAS CITY, Texas Nov 03, 08 Vessel Inspection - Approved Inspection
2895209 CAPE CANAVERAL, Florida Mar 21, 07 Boarding - Agency Action Complete
2891555 Cape Canaveral, Florida Mar 20, 07 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Construction/LoadlineMarkingsImproper Installation
DescriptionDue DateResolved
Vessels load line mark not permanately affixed nor did it match the vessel's Load Line certificate. Class to provide attestation to proper and accurate marking on boat port and starboard sides.Yes
Resolved DateResolution
Mar 22, 07Class report provided attesting to new load line and the vesse''s change in DWT.
2890855 Jacksonville, Florida Mar 19, 07 Vessel Operational Control - Agency Action Complete
2889846 Miami Beach, Florida Mar 18, 07 Vessel Operational Control - Agency Action Complete
2844306 Arlington, Virginia Dec 21, 06 Enforcement - Payment Received
2843476 STATEN ISLAND, New York Dec 20, 06 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
ElectricalElectric Generation Source (emergency)Improper/Lack of Maintenance
DescriptionDue DateResolved
Emergency generator not able to start due to batteries being too low on stored power, batteries were replaced and generator started satisfactorily. Item corrected while onboard.Dec 20, 06Yes
Resolved DateResolution
Dec 20, 06Item corrected while onboard.
SystemSubsystemCause
Deck/CargoInert Gas SystemDesign Flaw
DescriptionDue DateResolved
Hole located in the water supply for the deck water seal. Temporary repair have been made; make permanent repairs to the satisfaction of Class by 20 January 2007Jan 20, 07Yes
Resolved DateResolution
Mar 22, 07Class report provided stating that provisional repairs were adequate until permanent repairs could be made during the vessel''s 02 Aug 07 dry dock.
SystemSubsystemCause
DocumentationCertificates/DocumentsUnknown
DescriptionDue DateResolved
Ship was conducting cargo off load while in the Port of New York with an expired COC (10NOV06). The ship must go through a US Coast Guard Certificate of Compliance exam and pass prior to any cargo operations.Dec 20, 06Yes
Resolved DateResolution
Dec 20, 06Ship completed a satisfactory COC exam 1340 hrs 20DEC06.
2843436 Buzzards Bay, Massachusetts Dec 20, 06 Boarding - Agency Action Complete
2791697 New Orleans, Louisiana Oct 02, 06 Vessel Inspection - Administrative Action
2635716 CORPUS CHRISTI, Texas May 03, 06 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Construction/LoadlineMarkings
DescriptionDue DateResolved
Load line not permanently marked with summer line in accordance with load line certificate. Deficiency is due AFTER drydock in Sep '06.Oct 01, 06Yes
Resolved DateResolution
Oct 02, 06Received class report from BV satisfying requirement.
2619834 SAN DIEGO, California Apr 07, 06 Boarding - Agency Action Complete
2516420 Houston, Texas Oct 17, 05 Vessel Operational Control - Approved Inspection
2426940 San Pedro, California Jul 14, 05 Vessel Inspection - Approved Inspection
2364880 San Pedro, California May 22, 05 Boarding - Agency Action Complete
2341886 San Francisco, California Apr 24, 05 Boarding - Agency Action Complete
2339382 San Francisco, California Apr 21, 05 Boarding - Agency Action Complete
2300304 CORPUS CHRISTI, Texas Feb 27, 05 Boarding - Agency Action Complete
2246590 STATEN ISLAND, New York Nov 23, 04 Vessel Inspection - Administrative Action
2235945 NEW HAVEN, Connecticut Nov 10, 04 Vessel Inspection - Agency Action Complete
  4
SystemSubsystemCause
Deck/CargoMooring/AnchoringDamaged By Earlier Event
DescriptionDue DateResolved
Anchor windlass hydraulic motors inoperative due to bad weather. Water entered into the forward bosum locker and damaged the electrical panel to the windlass'.Nov 11, 04Yes
Resolved DateResolution
Nov 22, 04cleared via class report
SystemSubsystemCause
LifesavingInflatable LiferaftsDamaged By Earlier Event
DescriptionDue DateResolved
Forward 6 person liferaft is missing due to bad weather. Needs to be replaced to the satisfaction of class prior to international voyage.Nov 13, 04Yes
Resolved DateResolution
Nov 22, 04cleared via class report
SystemSubsystemCause
LifesavingEmbarkation Appliances/StationsDamaged By Earlier Event
DescriptionDue DateResolved
The last ten meters of the safe access to tanker bow is missing due to bad weather in transit.Nov 30, 04Yes
Resolved DateResolution
Nov 22, 04cleared via class report
SystemSubsystemCause
Deck/CargoTowingDamaged By Earlier Event
DescriptionDue DateResolved
Vessel's emergency towing arrangement forward is inoperative, due to bad weather.Yes
Resolved DateResolution
Nov 22, 04cleared via class report
Documents Issued Expires Agency
Classification Document December 4,2019 December 3,2024 LR
COC-TVE Annual November 13,2009 November 4,2010 N/A
COC-TVE Renewal November 4,2008 November 4,2010 N/A
International Load Line Certificate December 4,2019 August 1,2024 LR
International Oil Pollution Prevention Certificate November 4,2016 November 3,2021 LR
Int'l Oil Poll Prevention, Form B Supplement June 28,2017 LR
ISM - Document Of Compliance May 26,2017 May 25,2022 LR
ISM - Safety Management Certificate October 6,2021 November 3,2026 LR
Minimum Safe Manning Document July 26,2020 July 25,2025 SG
NLS Certificate May 9,2012 August 1,2014 LR
SOLAS Cargo Ship Safety Construction Certificate December 4,2020 August 1,2024 LR
SOLAS Cargo Ship Safety Equipment Certificate December 4,2019 August 1,2024 LR
SOLAS Cargo Ship Safety Radio Certificate July 23,2019 August 1,2024 LR
Tonnage Certificate, International July 14,2017 LR