Coral Meandra
Print Q88   
IMO/VIN Callsign Flag Service Year
9129380 D5JU6 LIBERIA Tank Ship 1996
Activity# Port Date Activity - Description Deficiencies
6605723 Houston, Texas Jan 10, 19 Vessel Inspection - Approved Inspection
  1   2
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper Installation
DescriptionDue DateResolved
Airlock doors should be self-closing. Self-closing devices are missing from airlock doors on Nitrogen PSA Room located within a hazardous zone. 74SOLAS(14)VII/13.1 93 IGC 3.6.2 17acNo
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
An audible and visual alarm system to give a warning on both sides of the airlock should be provided to indicate if more than one door is moved from the closed position. Audible alarm for nitrogen PSA room airlock is inoperable/missing. 74SOLAS(14)VII/13.1 93 IGC 3.6.3 17acNo
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
Electrical equipment, cables and wiring should not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable by the organization. Stbd flood light above nitrogen PSA room in hazardous zone wiring exposed. 74SOLAS(14)VII/13.1 93 IGC 10.1.4 10cYes
Resolved DateResolution
Jan 10, 19Electrician repaired the exposed wiring by replacing the stuffing material in the presence of both PSCOs and Class BV surveyor.
6093603 Houston, Texas Mar 03, 17 Vessel Inspection - Approved Inspection
3533574 Houston, Texas Jul 13, 09 Vessel Inspection - Approved Inspection
3528866 Houston, Texas Jul 09, 09 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
Vessel does not have proper span gas onboard the vessel to calibrate the portable meters as required by code. Cite IGC 13.6.6. Rectify def within the nest 7 days to the satisfaction of the CG.Jul 16, 09Yes
Resolved DateResolution
Jul 13, 09Received copy of vessel''s receipt attesting to span gas having been delivered.
3522563 Houston, Texas Jul 08, 09 Boarding - Agency Action Complete
2888633 Houston, Texas Mar 15, 07 Vessel Inspection - Agency Action Complete
2888111 Houston, Texas Mar 14, 07 Boarding - Approved Inspection
2887060 Houston, Texas Mar 13, 07 Vessel Operational Control - Agency Action Complete
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
13Mar2007: Vessel issued a Letter of Deviation for an inoperable second radar. The vessel must submit a technician report attesting to repairs prior to departure.Yes
Resolved DateResolution
Mar 15, 07Radar operating properly. Vessel released from op control.
1092135 PHILADELPHIA, Pennsylvania May 09, 97 Vessel Inspection - Agency Action Complete
403623 PHILADELPHIA, Pennsylvania May 09, 97 Vessel Inspection - Agency Action Complete
  4
SystemSubsystemCause
Fire FightingUnknown
DescriptionDue DateResolved
CONTROL SWITCH FOR EMERGENCY FIRE PUMP ON THE BRIDGE DID NOT START THE FIREPUMP Jun 09, 97Yes
Resolved DateResolution
May 18, 02MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
EMERGENCY SHOWERS DID NOT HAVE ADEQUATE WATER PRESSURE Aug 09, 97Yes
Resolved DateResolution
May 18, 02MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
SystemSubsystemCause
NavigationUnknown
DescriptionDue DateResolved
MANEUVERING FACT SHEET WAS MISSING THE WARNING STATEMENT. May 11, 97Yes
Resolved DateResolution
May 13, 97
SystemSubsystemCause
Fire FightingUnknown
DescriptionDue DateResolved
THE VESSEL'S STARBOARD SIDE INTERNATIONAL SHORE CONNECTION WAS INSTALLED INA WAY THAT WOULD NOT ALLOW THE CONNECTION OF A FIRE HOSE. THE CONNECTION WAS BLOCKED BY A STANTION. Jun 09, 97Yes
Resolved DateResolution
May 18, 02MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel January 10,2019 January 10,2021 N/A
Certificate of Fitness - Gas Carrier January 10,2019 January 10,2021 N/A
Classification Document January 17,2017 October 31,2021 BV
International Certificate of Fitness - Gas Carrier January 17,2017 October 31,2021 NL
International Load Line Certificate January 17,2017 October 31,2021 GL
International Oil Pollution Prevention Certificate October 31,2006 October 31,2011 N/A
ISM - Document Of Compliance January 19,2018 September 28,2021 BV
ISM - Safety Management Certificate February 23,2007 July 23,2007 DNV
Load Line Certificate (Coastwise) March 19,1997 June 30,1997 N/A
Minimum Safe Manning Document October 17,2016 LR
NLS Certificate January 17,2017 October 31,2021 BV
SOLAS Cargo Ship Safety Certificate January 17,2017 October 31,2021 BV
SOLAS Cargo Ship Safety Construction Certificate January 17,2017 October 31,2021 BV
SOLAS Cargo Ship Safety Equipment Certificate January 17,2017 October 31,2021 BV
SOLAS Cargo Ship Safety Radio Certificate January 17,2017 October 31,2021 BV
Subchapter O Endorsement May 9,1997 May 9,1999 N/A
Tonnage Certificate, International November 3,2016 BV