Yucatan
Print Q88   
IMO/VIN Callsign Flag Service Year
1055441 WCX6377 UNITED STATES Tank Barge 1998
Activity# Port Date Activity - Description Deficiencies
7049483 New Orleans, Louisiana Sep 03, 20 Facility Transfer Monitor - Approved Inspection
7035463 New Orleans, Louisiana Aug 27, 20 Vessel Inspection - Approved Inspection
6961882 STATEN ISLAND, New York May 27, 20 Vessel Inspection - Administrative Action
6776146 Port Arthur, Texas Aug 09, 19 Vessel Inspection - Approved Inspection
6723683 CORPUS CHRISTI, Texas Jun 23, 19 Vessel Inspection - Approved Inspection
6525128 New Orleans, Louisiana Aug 26, 18 Vessel Inspection - Approved Inspection
6518028 Port Arthur, Texas Aug 20, 18 Vessel Inspection - Approved Inspection
6489112 Houston, Texas Jul 24, 18 Vessel Inspection - Approved Inspection
6471310 Port Arthur, Texas Jul 02, 18 Vessel Inspection - Approved Inspection
6383687 New Orleans, Louisiana Mar 23, 18 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
46CFR32.50-35 Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine, whichever is the more practical. Barge rep reported the mechanical E-stop for the stbd cargo pump being repaired during this yard period. STBD cargo pump is not to be used until OCMI conducts sat test of E-stop.Yes
Resolved DateResolution
Jul 02, 18Mechanical E-Stop for STBD cargo pump repaired and tested.
6121551 New Orleans, Louisiana Apr 13, 17 Vessel Inspection - Approved Inspection
5872734 ST PETERSBURG, Florida Apr 20, 16 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Cargo pump shaft bulkhead seals are not gas tight IAW 46 CFR 111.105-5.Yes
Resolved DateResolution
Aug 03, 16Cargo pump seals replaced.
SystemSubsystemCause
EngineeringSteam Boiler (auxiliary/waste heat)
DescriptionDue DateResolved
Fuel leak on return line, port side thermal fluid heater, must be repaired IAW 46 CFR 61.30.Yes
Resolved DateResolution
Aug 03, 16Fuel leak repaired, no further issues.
5872734 Tampa, Florida Apr 20, 16 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Cargo pump shaft bulkhead seals are not gas tight IAW 46 CFR 111.105-5.Yes
Resolved DateResolution
Aug 03, 16Cargo pump seals replaced.
SystemSubsystemCause
EngineeringSteam Boiler (auxiliary/waste heat)
DescriptionDue DateResolved
Fuel leak on return line, port side thermal fluid heater, must be repaired IAW 46 CFR 61.30.Yes
Resolved DateResolution
Aug 03, 16Fuel leak repaired, no further issues.
5838507 New Orleans, Louisiana Mar 23, 16 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoMooring/Anchoring
DescriptionDue DateResolved
Vessel authorized to transit LMR with tug(s) assist to loading berth Valero St. Charles and return to Perry St. Wharf to await anchor installation and surveys.Apr 01, 16Yes
Resolved DateResolution
Mar 25, 16Replaced anchor and attachments IAW ABS rules. Received class report and masters statement. all sat.
SystemSubsystemCause
Deck/CargoMooring/Anchoring
DescriptionDue DateResolved
Vessel lost the flukes of anchor upon retrieval at mm 74 LMR. Provide documentation from ABS to the proper installation and satisfaction of newly installed anchor. See attached YUCATAN_3-22-16_835 for further details.Mar 22, 16Yes
Resolved DateResolution
Mar 23, 16Restriction cleared to Perry St. Wharf cleared. Vessel authorized transit with tug(s) assist to loading berth, Valero St. Charles.
5832744 WASHINGTON, District of Columbia Mar 17, 16 Incident Investigation - Agency Action Complete
5830768 Port Arthur, Texas Mar 11, 16 Vessel Inspection - Approved Inspection
5827285 TEXAS CITY, Texas Mar 04, 16 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoHolds/TanksImproper/Lack of Maintenance
DescriptionDue DateResolved
Cargo weeping into #3 port ballast tank. Vessel is permitted to transit to GTI to discharge. Upon completion, proceed to shipyard to affect permanent repairs to the satisfaction of the attending marine inspector prior to loading cargo.Yes
Resolved DateResolution
Mar 12, 16Vessel had shipyard gouge and reweld insert. Inspectors witnessed satisfactory air test of #3 cargo tank.
5112548 Port Arthur, Texas Apr 30, 15 Vessel Inspection - Approved Inspection
5043004 WASHINGTON, District of Columbia Dec 15, 14 Incident Investigation - Agency Action Complete
5025389 WASHINGTON, District of Columbia Nov 17, 14 Incident Investigation - Agency Action Complete
4989095 WASHINGTON, District of Columbia Aug 26, 14 Incident Investigation - Agency Action Complete
4933712 TEXAS CITY, Texas Jul 25, 14 Vessel Inspection - Approved Inspection
4540262 ST PETERSBURG, Florida Feb 27, 13 Vessel Inspection - Approved Inspection
4540262 Tampa, Florida Feb 27, 13 Vessel Inspection - Approved Inspection
4287706 New Orleans, Louisiana Apr 16, 12 Vessel Inspection - Approved Inspection
  9
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
120v panel ground indicator light, located in the entrance to the bow thruster room, is out.Apr 21, 12Yes
Resolved DateResolution
Apr 20, 12Tech replaced two burned out ground indicator bulbs on 120v panel.
SystemSubsystemCause
ElectricalElectric Supply System (service)
DescriptionDue DateResolved
Conduct maintenance and test or replace bow thruster batteries; bow thruster batteries leaking electrolyte.Apr 28, 12Yes
Resolved DateResolution
Apr 26, 12Testing and maintenance conducted on two Bow thruster room batteries. Battery for staring system was found faulty, replaced in kind.
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Dead end wires located on #2 ships service generator.Apr 21, 12Yes
Resolved DateResolution
Apr 20, 12Dead end wires from previously removed 12v alternator system were cut flush, end capped and taped over with electrical tape.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Detected a ground fault on phase " B" of the 480v distribution panel.Apr 16, 12Yes
Resolved DateResolution
Apr 17, 12Received and accepted Blue water Electric, LLC Tech''s report stating the ground fault on the main switch board was due to a water fouled light fixture. Tech removed water, properly sealed and tested system. Ground fault cleared.
SystemSubsystemCause
ElectricalLighting (emergency)
DescriptionDue DateResolved
Emergency light fixer to the ships service generator room has broken light lens.Apr 28, 12Yes
Resolved DateResolution
Apr 26, 12Emergency light fixer repaired to the satisfaction of the attending Coast Guard Marine Inspector.
SystemSubsystemCause
ElectricalElectrical Distribution System (emergency)
DescriptionDue DateResolved
Make operable emergency lights in the Bow Thruster Room.Apr 28, 12Yes
Resolved DateResolution
Apr 26, 12Emergency light in bow thruster room repaired to the satisfaction of the attending Coast Guard Marine Inspector.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Provide and install seals for the overfill rising stick gauges.Apr 21, 12Yes
Resolved DateResolution
Apr 20, 12Crew replaced missing O-ring seals to overfill rising stick gauges.
SystemSubsystemCause
EngineeringFuel Oil Service System
DescriptionDue DateResolved
Replace fuel/oil hoses from secondary filter to governor housing on #2 and #1 ships service generators with hoses meeting SAE J1942 standards.Apr 28, 12Yes
Resolved DateResolution
Apr 26, 12Crew replaced non approved fuel/oil hoses with hoses meeting SAE J1942 standards on the #1 and #2 ships service generators.
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)
DescriptionDue DateResolved
Starboard cargo pump's prime mover failed emergency shutdown test.Apr 16, 12Yes
Resolved DateResolution
Apr 17, 12Received , reviewed and accepted proper repair documentation from Marine Systems Inc., Tech. Prime mover shut down operational.
4004084 ST PETERSBURG, Florida Apr 25, 11 Vessel Inspection - Approved Inspection
4004084 Tampa, Florida Apr 25, 11 Vessel Inspection - Approved Inspection
3870016 New Orleans, Louisiana Oct 14, 10 Vessel Inspection - Approved Inspection
3855905 TEXAS CITY, Texas Sep 23, 10 Vessel Inspection - Approved Inspection
3855190 WASHINGTON, District of Columbia Sep 22, 10 Incident Investigation - Agency Action Complete
3781242 New Orleans, Louisiana Jun 30, 10 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
StabilityWatertight Integrity
DescriptionDue DateResolved
Chaulk test all watertight doors and replace gaskets that do not seal properly.Aug 01, 10Yes
Resolved DateResolution
Oct 14, 10Watertight doors chaulk tested and faulty gaskets replaced.
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Make operable the vessels hotel services generator.Aug 01, 10Yes
Resolved DateResolution
Oct 14, 10Reveiwed tech report, generator repaired and test run SAT.
3747019 NEW HAVEN, Connecticut May 20, 10 Facility Transfer Monitor - Agency Action Complete
3536433 Houston, Texas Jul 16, 09 Vessel Inspection - Approved Inspection
3161351 STATEN ISLAND, New York Mar 10, 08 Vessel Inspection - Agency Action Complete
3087579 TEXAS CITY, Texas Oct 26, 07 Enforcement - Agency Action Complete
3087572 TEXAS CITY, Texas Oct 26, 07 Enforcement - Agency Action Complete
3087557 TEXAS CITY, Texas Oct 26, 07 Enforcement - Agency Action Complete
3030891 New Orleans, Louisiana Aug 17, 07 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
Deck/CargoTowing
DescriptionDue DateResolved
Barge's hurricane plan must be followed. Any requests to deviate from the plan must be approved by OCMI New Orleans.Yes
Resolved DateResolution
Aug 22, 07Not applicable.
SystemSubsystemCause
Deck/CargoTowing
DescriptionDue DateResolved
If a hurricane is predicted to threaten the area, the barge must be shifted by tugs of adequate horsepower to Ama Anchorage above Kenner Bend. A federal pilot must be onboard for the transit.Yes
Resolved DateResolution
Aug 29, 07Not applicable.
SystemSubsystemCause
Deck/CargoTowing
DescriptionDue DateResolved
Proceed directly from Davant Anchorage, MM52 LMR, to Napoleon Ave Berth C at Port of NOLA. Tugs of adequate horsepower shall shift barge from Davant to Napoleon Ave Berth. A federal pilot must be onboard for transit.Aug 19, 07Yes
Resolved DateResolution
Aug 18, 07Barge shifted from Davant Anchorage to Milan St Berth at Port of NOLA.
SystemSubsystemCause
EngineeringShafting/Propeller ArrangementsUnknown
DescriptionDue DateResolved
Provide satisfactory class report to OCMI New Orleans. Until such time, vsl is restricted to Davant Anchorage, MM52 LMR.Aug 18, 07Yes
Resolved DateResolution
Aug 17, 07Sat. ABS class report provided.
SystemSubsystemCause
EngineeringShafting/Propeller ArrangementsUnknown
DescriptionDue DateResolved
Provide satisfactory repair proposal to OCMI New Orleans. Until such time, vsl is restricted to Davant Anchorage, MM52 LMR.Aug 18, 07Yes
Resolved DateResolution
Aug 17, 07Sat. repair proposal provided. Tug will transit to International Shipyard in Tampa for repairs. Barge will remain at anchorage in SECNOLA.
2990324 TEXAS CITY, Texas Jul 10, 07 Enforcement - Agency Action Complete
2951134 CORPUS CHRISTI, Texas Jun 04, 07 Vessel Inspection - Approved Inspection
2862919 Houston, Texas Jan 28, 07 Vessel Inspection - Agency Action Complete
2874694 WASHINGTON, District of Columbia Jan 27, 07 Incident Investigation - Agency Action Complete
2816321 CORPUS CHRISTI, Texas Nov 07, 06 Vessel Transfer Monitor - Approved Inspection
2737475 CORPUS CHRISTI, Texas Aug 06, 06 Vessel Transfer Monitor - Agency Action Complete
2603533 ST PETERSBURG, Florida Mar 16, 06 Vessel Inspection - Approved Inspection
2603533 Tampa, Florida Mar 16, 06 Vessel Inspection - Approved Inspection
2506785 New Orleans, Louisiana Oct 03, 05 Vessel Inspection - Approved Inspection
2473399 New Orleans, Louisiana Aug 25, 05 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Install new shaft gasket on starboard cargo pump shaft where shaft penitrates at the aft bulkhead.Sep 25, 05Yes
Resolved DateResolution
May 03, 06
SystemSubsystemCause
Deck/CargoCargo Heating
DescriptionDue DateResolved
Prove proper operation of audible alarm for port thermal fluid heater.Oct 25, 05Yes
Resolved DateResolution
May 03, 06
2228575 Washington, District of Columbia Oct 26, 04 Vessel Inspection - Security Plan Approved by MSC
2160949 CORPUS CHRISTI, Texas Aug 09, 04 Enforcement - Payment Received
2157235 CORPUS CHRISTI, Texas Aug 07, 04 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Failure to conduct annual or periodic inspection of a tank vessel, <1600 GT. Vessel is cargo operations restricted until the annual inspection is completed to the satisfaction of the attending Coast Guard Marine Inspector.Yes
Resolved DateResolution
Aug 07, 04Conducted annual inspection.
2016386 Washington, District of Columbia Feb 17, 04 Vessel Inspection - Security Plan Approved by MSC
1980859 Washington, District of Columbia Dec 12, 03 Vessel Inspection - ASP Criteria Met
1743970 ST PETERSBURG, Florida Aug 29, 03 Vessel Inspection - Approved Inspection
1743970 Tampa, Florida Aug 29, 03 Vessel Inspection - Approved Inspection
1775963 STATEN ISLAND, New York Apr 18, 03 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Deck/CargoBallast
DescriptionDue DateResolved
Prove proper operation of ballast pumps. Accidentaly cleared item 02 from BOSMS. LEGACY COMPONENT DESC: PumpsApr 25, 03Yes
Resolved DateResolution
Aug 29, 03Witnessed proper operation of ballast pumps. Item cleared 29AUG03 TAMMS
1751817 BOSTON, Massachusetts Mar 05, 03 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
Deck/CargoMooring/Anchoring
DescriptionDue DateResolved
Prove proper operation of anchor windlass and brake. LEGACY COMPONENT DESC: WinchApr 25, 03Yes
Resolved DateResolution
Apr 18, 03
SystemSubsystemCause
Deck/CargoBallast
DescriptionDue DateResolved
Prove proper operation of ballast pumps. LEGACY COMPONENT DESC: PumpsApr 25, 03Yes
Resolved DateResolution
Apr 18, 03
SystemSubsystemCause
EngineeringThrusters
DescriptionDue DateResolved
Prove proper operation of bow thruster.Apr 25, 03Yes
Resolved DateResolution
Apr 18, 03
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
Prove proper operation of flashing yellow navigation light. LEGACY COMPONENT DESC: Navigation LightsApr 25, 03Yes
Resolved DateResolution
Apr 18, 03
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Restencil cargo hoses with proper MAWP of 150 psi. LEGACY COMPONENT DESC: Transfer HoseApr 25, 03Yes
Resolved DateResolution
Apr 18, 03
1495088 Houston, Texas Mar 19, 02 Vessel Inspection - Agency Action Complete
1403314 ST PETERSBURG, Florida Mar 14, 01 Vessel Inspection - Agency Action Complete
1403314 Tampa, Florida Mar 14, 01 Vessel Inspection - Agency Action Complete
465558 CORPUS CHRISTI, Texas Feb 05, 01 Vessel Transfer Monitor - Agency Action Complete
147088 WASHINGTON, District of Columbia Aug 10, 00 Incident Investigation - Agency Action Complete
816661 CORPUS CHRISTI, Texas Mar 21, 00 Vessel Inspection - Agency Action Complete
1389010 Jacksonville, Florida Feb 29, 00 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringUnknown
DescriptionDue DateResolved
PERFORM ALL REQUIRED SAFETY TESTS ON THE PORT AND STARBOARD THERMAL FLUID HEATERS. Feb 29, 00Yes
Resolved DateResolution
Feb 29, 00
1128054 Miami Beach, Florida May 05, 99 Vessel Inspection - Agency Action Complete
1470209 Miami Beach, Florida Apr 08, 99 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Prior to 08MAY99, provide affidavit of pressure tests of cargo pump pressure relief valves IAW 46 CFR 35.35-70(b). Apr 08, 99Yes
Resolved DateResolution
Apr 08, 99
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Prior to 08MAY99, provide an affidavit of hydrostatic testing of cargo pipelines IAW 46 CFR 35.35-70(d). Apr 08, 99Yes
Resolved DateResolution
Apr 08, 99
123088 WASHINGTON, District of Columbia Jan 20, 99 Incident Investigation - Agency Action Complete
539864 Cape Canaveral, Florida Jul 11, 98 Vessel Transfer Monitor - Agency Action Complete
1434684 New Orleans, Louisiana Mar 09, 98 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Fire FightingUnknown
DescriptionDue DateResolved
PROVIDE TO OCMI NEW ORLEANS AN UPDATED COPY OF THE FIRE SAFETY PLAN (3 COPIES). Mar 23, 98Yes
Resolved DateResolution
Mar 18, 98
Documents Issued Expires Agency
CERTIFICATE OF DOCUMENTATION November 25,2020 November 30,2021 USCG
Certificate of Inspection February 29,2000 March 31,2003 N/A
Certificate of Inspection - Amended February 29,2000 March 31,2003 N/A
Classification Document June 3,2013 March 31,2018 ABS
International Load Line Certificate June 3,2013 March 31,2018 ABS
International Oil Pollution Prevention Certificate May 28,2013 May 28,2018 N/A
Load Line Certificate (Coastwise) July 8,2003 March 31,2008 ABS
Tonnage Certificate, International March 5,1998 ABS