Tenna Kosan
Print Q88   
IMO/VIN Callsign Flag Service Year
9160475 9HA5469 MALTA Tank Ship 1998
Activity# Port Date Activity - Description Deficiencies
7370069 Houston, Texas Dec 18, 21 Vessel Inspection - Approved Inspection
7084455 Victoria, Texas Oct 31, 20 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
On ships carrying Flammable of toxic products or both, a water spray system for cooling, fire prevention and crew protection are to be installed to cover exposed cargo tank domes and any exposed parts of cargo tanks. 01 nozzle on exposed deck tank were in operable. 74SOLAS(14)CH. VII Reg. 13.1 IGC 11.3.1.1Yes
Resolved DateResolution
Oct 31, 20Recieved Class report attesting to the repair of the nozzle.
6232943 Victoria, Texas Aug 08, 17 Vessel Inspection - Approved Inspection
6101176 Lake Charles, Louisiana Mar 13, 17 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Fire FightingStructural - A Class DivisionsImproper Installation
DescriptionDue DateResolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. PSCOS observed the paint locker door and chemical store door to be B class doors, without self-closing mechanisms. According to the ship Fire Control Plan both doors are required to be A class self-closing doors.Yes
Resolved DateResolution
Aug 08, 17Vessel installed Class A-60 self closing fire doors in paint storage room and chemical storage room in accordance with approved fire control plan.
5774398 Port Arthur, Texas Dec 06, 15 Vessel Inspection - Approved Inspection
4999790 CORPUS CHRISTI, Texas Oct 13, 14 Vessel Inspection - Approved Inspection
4688495 Lake Charles, Louisiana Aug 22, 13 Vessel Inspection - Approved Inspection
4262390 CORPUS CHRISTI, Texas Mar 18, 12 Vessel Inspection - Approved Inspection
3747012 Miami Beach, Florida May 25, 10 Vessel Operational Control - Agency Action Complete
3740143 New Orleans, Louisiana May 17, 10 Vessel Inspection - Approved Inspection
3563104 Houston, Texas Aug 12, 09 Vessel Inspection - Approved Inspection
3451536 Houston, Texas Apr 13, 09 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Vessel waste oil incinerator tank has the capabilites to transfer waste oil to the vessel's bilge water holding tank. This equipment does not match the vessel approved drawings. Vessel shall submit a report from certificate issuing authority attesting to the modifications of the equipment. MARPOL Consol 2006 Annex I Reg 6.4.2Yes
Resolved DateResolution
Aug 19, 09Class report attesting to the connection to bilge water holding tank removed.
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Vessel's IOPP states the incinerator can burn sludge at 21l/hr. The vessel has a document from the administration attesting to the incinerator being able to burn at 37kg/hr. The certificate issuing authority shall reflect the new burning rate on the IOPP. MARPOL Consol. 2006 Annex I Reg 7.1Yes
Resolved DateResolution
Aug 19, 09Class report attesting to new IOPP certficate received
3448878 Houston, Texas Apr 12, 09 Boarding - Agency Action Complete
3073532 Houston, Texas Oct 05, 07 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringDiesel Engine (propulsion-electric)Improper/Lack of Maintenance
DescriptionDue DateResolved
The vessel's #2 ship service generator has a fuel leak located at the connections of the governor.Yes
Resolved DateResolution
Oct 09, 07Received satisfactory class report.
2959619 Houston, Texas Jun 12, 07 Vessel Inspection - Agency Action Complete
2841824 CORPUS CHRISTI, Texas Dec 22, 06 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Operations/ManagementBallast Water Managment
DescriptionDue DateResolved
Vessel was still unable to provide a vessel specific ballast water management plan after being issued a deficiency in Aug.2006. Vessel is to provide a BWM plan PRIOR to entry next U.S. port to the satisfaction of the Coast Guard. BWM section in safety management system does not meet the requirement of BMW plan. Their ballast water reporting form also needs updating.Yes
Resolved DateResolution
Jun 12, 07Received copy of Ballast water plan and reporting forms.
2840274 CORPUS CHRISTI, Texas Dec 21, 06 Boarding - Agency Action Complete
2763482 Houston, Texas Aug 29, 06 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
ElectricalElectric Generation Source (emergency)
DescriptionDue DateResolved
Emergency Generator is not readily accessible from the open deck. Provide class/Administration statement verifying this is an allowed arrangement.Yes
Resolved DateResolution
Dec 22, 06Received class report. See attached document. The EG room is apparently located above the uppermost continuous deck.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Fixed gas detection sensor in Nitrogen Generator room does not provide reliable LEL reading. Until sensor is repaired or replaced, bussel is to provide portable alternative which will satisfy sampling and analysing requirements of IGC Code.Yes
Resolved DateResolution
Dec 06, 15Received class report. See attached document.
SystemSubsystemCause
Operations/ManagementBallast Water Managment
DescriptionDue DateResolved
Vessel unable to provide evidence of ship specfic ballast water management plan.Yes
Resolved DateResolution
Jun 12, 07Received e-copy of ballast water plan.
2762521 TEXAS CITY, Texas Aug 28, 06 Boarding - Agency Action Complete
2214199 New Orleans, Louisiana Oct 06, 04 Vessel Inspection - Approved Inspection
2054801 TEXAS CITY, Texas Apr 29, 04 Vessel Inspection - Approved Inspection
  6
SystemSubsystemCause
Fire FightingSelf-contained Breathing ApparatusUnknown
DescriptionDue DateResolved
HAVE AIR COMPRESSOR FOR SCBA'S SERVICED BY A THIRD PARTY EXPERT IAW IGC 14.2.6May 29, 04Yes
Resolved DateResolution
Oct 06, 04Deficiency cleared by NEWMS.
SystemSubsystemCause
Deck/CargoHolds/TanksUnknown
DescriptionDue DateResolved
HAVE CERTIFICATE ISSUING AUTHORITY PROVIDE A REPORT ATTESTING TO THE PROPER OPERATION OF ALL HIGH PRESSURE ALARMS IAW IGC 13.1.4/13.4.1 LEGACY COMPONENT DESC: Tank Pressure Monitoring DeviceYes
Resolved DateResolution
Apr 30, 04CERTIFICATE ISSUING AUTHORITY PROVIDED A REPORT ATTESTING TO THE PROPER OPERATION OF ALL HIGH PRESSURE ALARMS IAW IGC 13.1.4/13.4.1
SystemSubsystemCause
Fire FightingFiremans OutfitUnknown
DescriptionDue DateResolved
IMMEDIATELY OPEN ALL FIRE STATIONS TO ENSURE AVAILABILITY OF ALL FIRE FIGHTING GEAR IAW SOLAS 74 AMMENDED, CHP II-2 /17.4Apr 30, 04Yes
Resolved DateResolution
Apr 30, 04
SystemSubsystemCause
LifesavingLifeboat EquipmentUnknown
DescriptionDue DateResolved
PROVIDE LIFEBOAT WITH A FIRST AID KIT IAW LSA CODE CHAPTER IV REG 4.4.8.20May 29, 04Yes
Resolved DateResolution
Oct 06, 04Deficiency cleared by NEWMS.
SystemSubsystemCause
NavigationPiloting/SteeringUnknown
DescriptionDue DateResolved
PROVIDE SHIP WITH 33 CFR PTS 125-199, 46 CFR 140-155, AND INLAND NAVIGATIONAL RULES IN ACCORDANCE WITH SOLAS 74 AMMENDED CHAPTER V REG. 20Yes
Resolved DateResolution
Oct 06, 04Deficiency cleared by NEWMS.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
SAFETY RELIEF VALVES ON DECK TANK HAVE 2 DATA PLATES ON THEM WITH THE SAME SERIAL NUMBERS AND DIFFERENT SET POINTS. PROVIDE A REPORT ATTESTING TO THE CORRECT SET POINTS ON RELIEF VALVES IAW IGC 8.2.5 LEGACY COMPONENT DESC: Relief ValveYes
Resolved DateResolution
Apr 30, 04VESSEL HAS PROVIDED A REPORT ATTESTING TO THE CORRECT SET POINTS ON RELIEF VALVES IAW IGC 8.2.5
1620487 TEXAS CITY, Texas May 24, 02 Vessel Inspection - Approved Inspection
1617649 Houston, Texas May 16, 02 Vessel Inspection - Agency Action Complete
1617640 TEXAS CITY, Texas May 15, 02 Vessel Inspection - Approved Inspection
1066207 STATEN ISLAND, New York May 30, 01 Vessel Inspection - Agency Action Complete
290451 STATEN ISLAND, New York May 30, 01 Vessel Inspection - Agency Action Complete
Documents Issued Expires Agency
Certificate of Fitness - Gas Carrier September 29,2008 October 8,2013 BV
Classification Document October 19,2013 October 8,2018 BV
International Certificate of Fitness - Gas Carrier December 2,2013 October 8,2018 BV
International Load Line Certificate July 2,2021 October 8,2023 BV
International Oil Pollution Prevention Certificate October 19,2013 October 8,2018 BV
ISM - Document Of Compliance October 29,1999 October 29,2004 BV
ISM - Safety Management Certificate March 20,2019 February 4,2024 IM
Load Line Certificate (Coastwise) August 18,2009 October 8,2013 BV
Minimum Safe Manning Document March 4,2014 April 2,2019 IM
NLS Certificate October 2,2013 October 8,2018 BV
SOLAS Cargo Ship Safety Construction Certificate September 10,2021 October 8,2023 BV
SOLAS Cargo Ship Safety Equipment Certificate September 28,2021 October 8,2023 BV
SOLAS Cargo Ship Safety Radio Certificate October 19,2013 October 8,2018 BV
Subchapter O Endorsement March 13,2017 March 13,2019 N/A
Tonnage Certificate, International September 3,2003 BV