6446960 Houston, Texas Jun 17, 18 Vessel Operational Control - Approved Inspection
5190638 Honolulu, Hawaii Jul 20, 15 Vessel Inspection - Approved Inspection
  8
SystemSubsystemCause
EngineeringCompressed Air System (control)Improper/Lack of Maintenance
DescriptionDue DateResolved
1499- Other(Prop. & Machinery Auxiliary) - Machinery and associated piping systems shall be of a design and construction adequate for the service for which it is intended. Ship's service air line in vicinity of 6S is severely wasted and holed. 74SOLAS(2001cons)II-1/26.1Aug 20, 15Yes
Resolved DateResolution
Aug 14, 15Ship service air line in vicinity of 6S renewed.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
1830-Cargo Transfer-Each transfer pipe system must not leak under static liquid pressure at least 1.5 times the maximum working pressure. Vacuum line on #3 cargo oil pump is visibly leaking. 33 CFR 156.170 (c)(a)Jul 20, 15Yes
Resolved DateResolution
Jul 20, 15Vessel repaired and pressure tested the pipe to the satisfaction of the PSCO
SystemSubsystemCause
Deck/CargoHolds/TanksImproper/Lack of Maintenance
DescriptionDue DateResolved
1835-Cargo Vent System- Venting arrangements shall be so designed and operated as to ensure that vacuum in cargo tanks does not exceed design standards. Vacuum side of PV Valve on 1P flame screen is dirty and will not allow passage of air. 74SOLAS (2001cons)II-2/59.1.2Jul 21, 15Yes
Resolved DateResolution
Jul 20, 15Vessel cleaned flame screen allowing the PV valve to properly operate.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
1835-Cargo Vent System-Vapor collection piping must me electrically bonded to the hull and must be eletrically continous. Bonding cables are broken or missing in several locations on deck. 46CFR 39.2001(c)Jul 21, 15Yes
Resolved DateResolution
Jul 20, 15Vessel installed bonding straps in cargo transfer piping were needed on deck to the satisfaction of PSCO.
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
1840- Instrumentation-A cargo tank must be equipped with a closed gauging device. Gauging system for port slop tank is not operational. 46CFR 39.2003(a)Jul 20, 15Yes
Resolved DateResolution
Aug 14, 15Ship''s crew replaced defective gauging device at cargo tank and demonstrated proper operation.
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
1850- Fire protection cargo deck area- Instrumentation shall be fitted for continuously indicating time oxygen content of the inert gas. Ships #2 Oxygen analyzer is not operational. 74SOLAS(2001cons) II-2/62.16.1.2Aug 20, 15Yes
Resolved DateResolution
Aug 14, 15Defective oxygen analyzer was replaced and proper operation demonstrated to attending examiner.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)Improper/Lack of Maintenance
DescriptionDue DateResolved
1870-Special requirements- Where cables which are installed in hazardous areas introduce the risk of fire or explosion, special precautions against such risks shall be taken. Cable support for electrical control on the mast riser are severely wasted and broken away. 74SOLAS(2001cons) II-1/45.5.4Aug 20, 15Yes
Resolved DateResolution
Aug 14, 15Repairs to cable supports near mast riser verified by attending examiner.
SystemSubsystemCause
Operations/ManagementVessel Safety Management
DescriptionDue DateResolved
2535-Development of Plans for Shipboard ops-Every company should develop, implement, and maintain a Safety Management System. PSCO discovered objective evidence, supported by the above 7 deficiencies, that the company has failed to implement an effective SMS. Recommend external audit. 74SOLAS(2009 cons.) IX/3.1; ISM CODE 1.4Aug 20, 15Yes
Resolved DateResolution
Aug 14, 15External audit conducted by RO on 29 July 2015. Documentation of audit provided on 14 Aug to attending examiner; deficiency cleared.
3919733 TEXAS CITY, Texas Jan 08, 11 Vessel Inspection - Approved Inspection
3919812 WASHINGTON, District of Columbia Dec 23, 10 Incident Investigation - Agency Action Complete
3914810 Houston, Texas Dec 22, 10 Vessel Transfer Monitor - Approved Inspection
3883404 Houston, Texas Nov 02, 10 Vessel Inspection - Approved Inspection
3855533 Houston, Texas Sep 23, 10 Vessel Inspection - Approved Inspection
3835184 TEXAS CITY, Texas Sep 05, 10 Vessel Inspection - Approved Inspection
3712989 Lewes, Delaware Apr 11, 10 Vessel Inspection - Approved Inspection
3680123 TEXAS CITY, Texas Feb 15, 10 Vessel Inspection - Approved Inspection
3665607 CORPUS CHRISTI, Texas Jan 22, 10 Vessel Inspection - Approved Inspection
3426665 Lake Charles, Louisiana Mar 02, 09 Vessel Inspection - Approved Inspection
3426516 Lake Charles, Louisiana Mar 02, 09 Vessel Operational Control - Agency Action Complete
3231938 Christiansted, Virgin Islands Jun 10, 08 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
Make repairs to water supply line to the deck water seal. complete repairs prior to discharge of cargo to the satisfaction of the attending CG marine inspector.Yes
Resolved DateResolution
Jun 11, 08Witnessed feed water line repaired with liking kind.
2895970 CORPUS CHRISTI, Texas Apr 13, 07 Vessel Inspection - Approved Inspection
2896701 CORPUS CHRISTI, Texas Apr 12, 07 Boarding - Agency Action Complete
2634960 Christiansted, Virgin Islands May 15, 06 Vessel Inspection - Approved Inspection
2610078 Christiansted, Virgin Islands Mar 27, 06 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Walkway gratings for foam monitors and manifolds are wasted and have holes through them in multiple locations on deck. Provide temporary means for covering holes and provide permanent replacement of all wasted gratings prior to next U.S. port, but no later than 11APR2006 to the satisfaction of class.May 15, 06Yes
Resolved DateResolution
May 15, 06Received DNV class report attesting to satisfactory replacement of deck gratings.
2580027 STATEN ISLAND, New York Feb 06, 06 Boarding - Agency Action Complete
2586365 TEXAS CITY, Texas Jan 12, 06 Boarding - Agency Action Complete
2578685 TEXAS CITY, Texas Jan 11, 06 Boarding - Agency Action Complete
2425530 Port Arthur, Texas Jul 13, 05 Vessel Operational Control - Agency Action Complete
2408959 CORPUS CHRISTI, Texas Jul 02, 05 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
NavigationPiloting/Steering
DescriptionDue DateResolved
Vessel was issued a letter of deviation for an inoperable gyro compass (33 CFR 164.35(d).) This is based on the understanding that the equipment will be operable prior to departing the port of Corpus Christi. Yes
Resolved DateResolution
Jul 02, 05Received tech report via fax confirming that the repairs have been made and the equipment is operable.
2404880 CORPUS CHRISTI, Texas Jun 27, 05 Boarding - Agency Action Complete
2392729 Mobile, Alabama Jun 02, 05 Boarding - Agency Action Complete
2374743 Mobile, Alabama May 31, 05 Vessel Operational Control - Agency Action Complete
2340785 SOUTH PORTLAND, Maine Apr 22, 05 Vessel Inspection - Approved Inspection
2340536 SOUTH PORTLAND, Maine Apr 22, 05 Boarding - Agency Action Complete
2333776 SOUTH PORTLAND, Maine Apr 14, 05 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
O2 analyzer for IG system is inoperable. No COW ops in US waters and regular O2 readings of cargo tanks taken, until analyzer replaced and satisfactory operation verified by class.Yes
Resolved DateResolution
Apr 22, 05Cleared to the satisfaction of class and was verified. Two separate oxygen monitors were installed.
2299673 STATEN ISLAND, New York Feb 26, 05 Vessel Inspection - Approved Inspection
2247076 Houston, Texas Nov 23, 04 Vessel Operational Control - Approved Inspection
2221538 Houston, Texas Oct 15, 04 Boarding - Approved Inspection
2216823 Houston, Texas Oct 08, 04 Vessel Inspection - Agency Action Complete
2070180 PHILADELPHIA, Pennsylvania May 15, 04 Vessel Inspection - Approved Inspection
2037586 San Juan, Puerto Rico Apr 02, 04 Vessel Inspection - Approved Inspection
1055734 Honolulu, Hawaii Oct 24, 00 Vessel Inspection - Agency Action Complete
283053 Honolulu, Hawaii Oct 24, 00 Vessel Inspection - Agency Action Complete
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel October 24,2000 October 24,2001 N/A
Classification Document February 4,2000 February 29,2004 N/A
COC-TVE Annual March 27,2006 March 27,2008 N/A
COC-TVE Renewal September 7,2010 September 7,2012 N/A
International Load Line Certificate December 12,2008 November 5,2009 IRS
International Oil Pollution Prevention Certificate December 12,2008 November 5,2009 IRS
ISM - Document Of Compliance November 23,2012 December 3,2017 IN
ISM - Safety Management Certificate February 18,2014 March 2,2019 IN
Load Line Certificate (Coastwise) August 16,1999 February 27,2004 N/A
Minimum Safe Manning Document June 17,2014 IRS
SOLAS Cargo Ship Safety Construction Certificate December 12,2008 November 5,2009 IRS
SOLAS Cargo Ship Safety Equipment Certificate December 12,2008 November 5,2009 IRS
SOLAS Cargo Ship Safety Radio Certificate December 12,2008 November 5,2009 IRS
Tonnage Certificate, International September 9,1999 IN