Uacc Ibn Sina
Print Q88   
IMO/VIN Callsign Flag Service Year
9485629 9HTT9 MALTA Tank Ship 2008
Activity# Port Date Activity - Description Deficiencies
6640967 Christiansted, Virgin Islands Mar 16, 19 Vessel Inspection - Approved Inspection
6250552 New Orleans, Louisiana Aug 30, 17 Vessel Inspection - Approved Inspection
4834983 Miami Beach, Florida Apr 13, 14 Vessel Inspection - Approved Inspection
4526485 Houston, Texas Feb 04, 13 Vessel Inspection - Approved Inspection
4194656 New Orleans, Louisiana Nov 23, 11 Vessel Inspection - Administrative Action
4166428 New Orleans, Louisiana Oct 17, 11 Vessel Inspection - Approved Inspection
  7
SystemSubsystemCause
DocumentationSafety/Response Plans/Programs
DescriptionDue DateResolved
0899 Other (acid pervention)-Vessels shall provide training, and conduct exercises in accordance with their Vessel Response Plan. Vessel is conducting training and drill associated with their SOPEP, but not specific to their Vessel Response Plan. 33 CFR 155.1055 and 1060Yes
Resolved DateResolution
Nov 23, 11Received, reviewed and accepted proper documentation from Fleet Management India PVT. LTD. stating the deficiency was rectified. Record of drills provided.
SystemSubsystemCause
ElectricalElectrical Distribution System (emergency)
DescriptionDue DateResolved
0950 Electrical equipment in general-All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed ground faults on the 440v and 220v circuits passing through the emergency generator switchboards. SOLAS II-1/45.1.3Oct 31, 11Yes
Resolved DateResolution
Oct 24, 11Received, reviewed and accepted class report from Lloyd’s Register stating 220V and 440V ground fault indicators repaired, tested and found satisfactory.
SystemSubsystemCause
Construction/LoadlineMarkings
DescriptionDue DateResolved
1299 Other (load lines)-The mark of the Authority by whom the load lines are assigned may be indicated alongside the load line ring. Vessel has A B marked beside the load line ring, but Lloyds Register issued the load line certificate. ICLL Reg 7Yes
Resolved DateResolution
Oct 24, 11Received, reviewed and accepted class report from Lloyd''s Register stating loadline painted with the correct letters for Lloyd''s Register.
SystemSubsystemCause
Construction/LoadlineMarkings
DescriptionDue DateResolved
1299 Other (load lines)-The ring, lines and letters shall be painted in white or yellow on a dark back ground. Vessels starboard load line was badly rusted and no longer in a contrasting color. ICLL Reg. 8Yes
Resolved DateResolution
Oct 24, 11Received, reviewed and accepted class report from Lloyd''s Register stating Starboard side loadline now found painted with contrasting color.
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
1530 Radar-Vessels tertiary radar (x band) is not capable of working properly. SOLAS V/19Yes
Resolved DateResolution
Oct 24, 11Received, reviewed and accepted class report from Lloyd''s Register stating radar was repaired tested and found satisfactory.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
1899 Other (tankers)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The pressure sensor on the #3 cargo line has been disconnected, and the gauge in the cargo control room for the #1 cargo line at the starboard manifold is showing 2 mpa while the system is not running. SOLAS V/19Yes
Resolved DateResolution
Oct 24, 11Received, reviewed and accepted class report from Lloyd''s Register stating all cargo line sensors repaired, tested and found satisfactory.
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
1899 Other (Tankers)-The Inert Gas system shall be designed and operated as to render and maintain the atmosphere of the cargo tanks non-flammable at all times. Vessels crew was unable to demonstrate the ability of the IGG system with all required audible and visual indicators and shutdowns. FSS Code. Ch. 15Yes
Resolved DateResolution
Oct 24, 11Received, reviewed and accepted class report from Lloyd''s Register stating IG Flue Gas System was attended by shore based workshop. Training held by Chief Engineer on proper operation.
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel April 10,2014 April 10,2016 N/A
Classification Document October 11,2018 November 27,2023 LR
COC-TVE Annual February 4,2013 October 17,2013 N/A
COC-TVE Renewal October 17,2011 October 17,2013 NEWMS
International Load Line Certificate October 11,2018 November 27,2023 LR
International Oil Pollution Prevention Certificate October 11,2018 November 27,2023 LR
ISM - Document Of Compliance June 7,2017 May 19,2020 DNV GL
ISM - Safety Management Certificate January 16,2019 April 7,2024 LR
Minimum Safe Manning Document September 28,2018 November 27,2023 MT
SOLAS Cargo Ship Safety Construction Certificate October 11,2018 November 27,2023 LR
SOLAS Cargo Ship Safety Equipment Certificate October 11,2018 November 27,2023 LR
SOLAS Cargo Ship Safety Radio Certificate October 11,2018 November 27,2023 LR
Tonnage Certificate, International November 28,2008 ABS