MTM Yangon
Print Q88   
IMO/VIN Callsign Flag Service Year
9250165 9V2087 SINGAPORE Tank Ship 2003
Activity# Port Date Activity - Description Deficiencies
6686361 Savannah, Georgia May 21, 19 Vessel Inspection - Approved Inspection
6485317 Savannah, Georgia Jul 24, 18 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
14 - Pollution Prevention142 - MARPOL Annex II
DescriptionDue DateResolved
14299:Every ship certified to carry substances of category X,Y or Z shall have onboard a manual approved by the administration. The manual shall have a standard format in compliance with appendix IV to this annex. Vessel could not produce a P&A manual showing currant tank cleaning or disposal of wash water procedures. Vessel is prohibited from conducting tank wash or disposal MARPOL ANNEX II REG 14.1Yes
Resolved DateResolution
Jul 27, 18Received, reviewed and accepted class report form ABS satisfying the requirement. Company updated P&A manual w/ABS approval.
SystemSubsystemCause
15 - Safety Management Systems (ISM)N/A - No Subsystem
DescriptionDue DateResolved
15108:The company and the ship shall comply with the requirements of the ISM code. For the purpose of this regulation the requirements of the code shall be considered mandatory. Every company should develop, implement and maintain SMS; report non-conformities. PSCO observed temperature sensors in cargo tanks not reading correct temperature. Master could not provide SMS report to company. SOLAS 14a (09) IX/3, ISM part A 1.4.4 16 a,cAug 07, 18Yes
Resolved DateResolution
Jul 27, 18Received, reviewed and accepted class report form ABS satisfying the requirement. Master filed non-conformity, and company conducted root cause analysis. Master completed training as per company instructions.
SystemSubsystemCause
14 - Pollution Prevention142 - MARPOL Annex II
DescriptionDue DateResolved
A chemical tanker shall comply with the requirements of the International Bulk Chemical code. The provision of this section are applicable were specific reference is made. PSCO observed #2S overfill and #5P high level alarm remain activated in Cargo control room. Vessel is prohibited from loading cargo’s that require high level/overfill alarms in 2pand 5s cargo tanks. SOLAS 74a (09) VII/10.1, IBC 15.9Yes
Resolved DateResolution
Jul 27, 18Received, reviewed and accepted class report form ABS satisfying the requirement. Ship’s crew cleaned tank level indicators w/successful test from ABS surveyor.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
A chemical tanker shall comply with the requirements of the International Bulk Chemical code. The provision of this section are applicable were specific reference is made. PSCO observed temperature sensors in cargo tanks not reading correct temperature. Ship’s crew reset the system and sensors auto calibrated to reflect correct temperature. SOLAS 74a (09) VII/10.1, IBC 7.1.5 10cJul 24, 18Yes
Resolved DateResolution
Jul 24, 18
6345206 BATON ROUGE, Louisiana Jan 31, 18 Vessel Inspection - Approved Inspection
6166300 Port Arthur, Texas Jun 07, 17 Vessel Inspection - Approved Inspection
5780303 TEXAS CITY, Texas Dec 14, 15 Vessel Inspection - Approved Inspection
5040933 New Orleans, Louisiana Dec 17, 14 Vessel Operational Control - Agency Action Complete
5040965 WASHINGTON, District of Columbia Dec 17, 14 Incident Investigation - Agency Action Complete
5033506 New Orleans, Louisiana Dec 14, 14 Vessel Inspection - Approved Inspection
4572980 STATEN ISLAND, New York Apr 20, 13 Vessel Inspection - Approved Inspection
4301066 Houston, Texas Oct 31, 12 Vessel Inspection - Approved Inspection
4178048 Port Arthur, Texas Nov 01, 11 Vessel Inspection - Approved Inspection
3868964 Brownsville, Texas Oct 29, 10 Vessel Inspection - Approved Inspection
3632175 Houston, Texas Nov 12, 09 Vessel Inspection - Approved Inspection
3594153 Port Arthur, Texas Sep 14, 09 Vessel Inspection - Approved Inspection
3601622 ST PETERSBURG, Florida Sep 10, 09 Boarding - Agency Action Complete
3589749 New Orleans, Louisiana Sep 09, 09 Boarding - Agency Action Complete
3444995 Miami Beach, Florida Apr 02, 09 Vessel Operational Control - Agency Action Complete
3422494 Mobile, Alabama Feb 23, 09 Vessel Inspection - Approved Inspection
3347990 New Orleans, Louisiana Oct 20, 08 Vessel Inspection - Administrative Action
3241378 STATEN ISLAND, New York Jun 19, 08 Vessel Operational Control - Administrative Action
3184874 Seattle, Washington Apr 15, 08 Vessel Inspection - Approved Inspection
3132500 Houston, Texas Jan 18, 08 Vessel Operational Control - Approved Inspection
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
The vessel requested an inbound deviation for an inoperable secondary marine radar. The vessel is required to have the radar repaired prior to departing the Port of Houston and submit the technicians report.Yes
Resolved DateResolution
Jan 18, 08RCVD tech report.
3128938 Brownsville, Texas Jan 11, 08 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
Primary Radar System-S Band is currently inoperative. 33 CFR 164.35(a)Yes
Resolved DateResolution
Jan 18, 08Unit is fully operational at this time verfied by Radio Holland USA.
3122614 TEXAS CITY, Texas Dec 30, 07 Vessel Inspection - Approved Inspection
2997992 NEW HAVEN, Connecticut Jul 17, 07 Vessel Transfer Monitor - Agency Action Complete
2980507 DANIA, Florida Jul 02, 07 Boarding - Agency Action Complete
2977279 Miami Beach, Florida Jun 29, 07 Vessel Operational Control - Agency Action Complete
2810322 STATEN ISLAND, New York Oct 30, 06 Vessel Inspection - Approved Inspection
2770939 PHILADELPHIA, Pennsylvania Sep 06, 06 Vessel Operational Control - Agency Action Complete
2615617 Woods Hole, Massachusetts Mar 31, 06 Boarding - Agency Action Complete
2536620 Jacksonville, Florida Nov 17, 05 Vessel Inspection - Agency Action Complete
2499050 STATEN ISLAND, New York Sep 22, 05 Boarding - Agency Action Complete
2335050 CORPUS CHRISTI, Texas Apr 16, 05 Boarding - Agency Action Complete
2306037 Port Arthur, Texas Mar 08, 05 Vessel Inspection - Agency Action Complete
2285857 Houston, Texas Feb 02, 05 Boarding - Approved Inspection
2259082 STATEN ISLAND, New York Dec 14, 04 Vessel Inspection - Agency Action Complete
2256058 STATEN ISLAND, New York Dec 09, 04 Vessel Inspection - Agency Action Complete
2118872 San Pedro, California Jul 02, 04 Vessel Operational Control - Agency Action Complete
2066930 San Pedro, California May 13, 04 Vessel Inspection - Approved Inspection
2065842 San Pedro, California May 12, 04 Enforcement - Payment Received
2049648 Wilmington, North Carolina Apr 21, 04 Vessel Inspection - Approved Inspection
2047239 North Charleston, South Carolina Apr 19, 04 Vessel Operational Control - Administrative Action
2044290 Christiansted, Virgin Islands Apr 15, 04 Vessel Inspection - Approved Inspection
2049169 Christiansted, Virgin Islands Apr 13, 04 Boarding - Agency Action Complete
2390225 Christiansted, Virgin Islands Apr 13, 04 Boarding - Agency Action Complete
2042761 Christiansted, Virgin Islands Apr 12, 04 Vessel Inspection - Approved Inspection
1999169 Christiansted, Virgin Islands Jan 21, 04 Vessel Inspection - Agency Action Complete
1999168 Christiansted, Virgin Islands Jan 18, 04 Vessel Inspection - Agency Action Complete
1962319 SOUTH PORTLAND, Maine Dec 10, 03 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
ElectricalLighting (service)Improper Installation
DescriptionDue DateResolved
2 electrical light fixtures on deck, stbd side just forward of the superstructure, had loose wire penetrations, allowing moisture into the fixtures.Yes
Resolved DateResolution
Dec 10, 03Crew cleaned out fixtures and tighten stuffing tubes.
SystemSubsystemCause
Construction/LoadlineStructuresImproper Installation
DescriptionDue DateResolved
In foam room, fwd bulkhead, a hole to fwd deck noted from a previous wire run left unplugged. Plug hole.Jan 10, 04Yes
Resolved DateResolution
Dec 10, 03Hole plugged.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
In steering room, the directional control valves electrical connections were loose, and easily removed.Yes
Resolved DateResolution
Dec 10, 03Screws tightened.
1958904 SOUTH PORTLAND, Maine Dec 04, 03 Vessel Inspection - Agency Action Complete
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel November 12,2009 November 12,2011 HOUMS
Certificate of Fitness - Chemical Carrier April 3,2018 March 3,2023 ABS
Classification Document April 3,2018 March 3,2023 ABS
International Certificate of Fitness - Chemical July 25,2018 September 6,2023 ABS
International Load Line Certificate April 3,2018 March 3,2023 ABS
International Oil Pollution Prevention Certificate March 26,2014 March 3,2018 ABS
ISM - Document Of Compliance September 2,2016 September 16,2021 ABS
ISM - Safety Management Certificate June 7,2018 September 6,2023 ABS
SOLAS Cargo Ship Safety Construction Certificate April 3,2018 March 3,2023 ABS
SOLAS Cargo Ship Safety Equipment Certificate April 3,2018 March 3,2023 ABS
SOLAS Cargo Ship Safety Radio Certificate February 19,2018 March 3,2023 ABS
Tonnage Certificate, International April 18,2013 July 18,2013 ABS